| Literature DB >> 26621351 |
Krystn Orr1, Holly S Howe2, Janine Omran3, Kristina A Smith4, Tess M Palmateer5, Alvin E Ma6, Guy Faulkner7.
Abstract
BACKGROUND: Given the widespread use of smartphone pedometer applications and the relatively limited number of published validity tests, this study examined the validity of three popular commercial smartphone pedometer applications (i.e., Accupedo, Moves, and Runtastic Pedometer). PARTICIPANTS: Convenience samples of males and females were recruited for laboratory tests [n = 11; mean: aged 24.18 years (±3.06)] and a free-living test [n = 18; mean: aged 28.78 years (±9.52)].Entities:
Mesh:
Year: 2015 PMID: 26621351 PMCID: PMC4666074 DOI: 10.1186/s13104-015-1705-8
Source DB: PubMed Journal: BMC Res Notes ISSN: 1756-0500
Participants’ descriptions (i.e., heights, mass, BMI, and age) are presented as a group and by testing condition
| Measure | Mean (Standard deviation) | ||
|---|---|---|---|
| Total | Laboratory test | Free-living test | |
| Height (m) | 1.71 (0.06) | 1.69 (0.04) | 1.72 (0.06) |
| Weight (kg) | 69.03 (13.28) | 60.39 (6.81) | 71.73 (13.85) |
| BMI (m/kg2) | 23.30 (3.78; 18.1–32.7) | 21.20 (2.34; 18.1–26.8) | 24.14 (3.98; 19.0–32.7) |
| Age (years) | 27.07 (8.31; 22–50) | 24.18 (3.06; 22–32) | 28.78 (9.52; 22–50) |
Fig. 1Percent error of each 20-step trial by device compared to the true count (i.e., 20)
Fig. 2Percent error of each 40-stair climbing trial by device compared to the true count (i.e., 40)
One-way repeated measures ANOVA results between groups at each treadmill speed are presented
| Speed (km/h) | Application | ANOVA | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Moves | Accupedo | Runtastic | Yamax | True count | ||||||||||
| M (SD) | Post-hoc | Zeros recorded | M (SD) | Post-hoc | Zeros recorded | M (SD) | Post-hoc | Zeros recorded | M (SD) | Post-hoc | Zeros recorded | M (SD) | ||
| 2 | 16.30* (33.35) | t(9) = −5.64 | 7 | 27.6* (31.41) | t(9) = −4.67 | 5 | 30.80* (29.30) | t(9) = −5.50 | 0 | 54.40* (24.89) | t(9) = −2.916 | 0 | 75.80 (9.53) | F(4,36) = 8.72 |
| 3 | 24.64* (36.11) | t(10) = −6.51 | 6 | 21.55* (23.45) | t(10) = −9.61 | 4 | 70.64 (42.00) | t(10) = −2.06 | 1 | 80.73 (25.88) | t(10) = −1.94 | 0 | 94.73 (8.09) | F(4,40) = 14.55 |
| 4.5 | 70.09 (59.79) | 4 | 76.55 (47.60) | 2 | 97.00 (53.93) | 0 | 104.82 (44.27) | 1 | 119.64 (11.41) | F(4,40) = 2.44 | ||||
| 6 | 28.00* (45.55) | t(10) = −8.88 | 6 | 103.18 (56.89) | t(10) = −1.90 | 1 | 119.00 (55.36) | t(10) = −0.97 | 0 | 138.09 (17.33) | t(10) = 0.65 | 0 | 134.91 (10.38) | F(4,40) = 18.86 |
| 8 | 80.20 * (74.59) | t(10) = −3.20 | 3 | 148.36 | t(10) = −0.06 | 0 | 143.82 (53.37) | t(10) = −0.32 | 0 | 165.91* (14.80) | t(10) = 2.84 | 0 | 148.82 (13.92) | F(2.0,19.7) = 7.09 |
| 9 | 80.09* (75.79) | t(10) = −3.94 | 3 | 156.36 (28.21) | t(10) = −0.79 | 0 | 168.27 (23.39) | t(10) = −0.79 | 0 | 170.36* (12.23) | t(10) = 2.39 | 0 | 162.55 (15.42) | F(1.4,14.3) = 12.56 |
| 10 | 79.18* (71.88) | t(10) = −4.68 | 1 | 167.82 | t(10) = 0.24 | 0 | 147.82 (57.70) | t(10) = −0.85 | 0 | 174.18* (12.58) | t(10) = 2.31 | 0 | 163.18 (19.19) | F(4,40) = 7.36 |
| 11 | 130.90 (101.50) | 3 | 166.10 (27.01) | 0 | 144.60 (49.16) | 0 | 175.50 (14.49) | 0 | 162.70 (25.10) | F(1.5,13.5) = 1.218 | ||||
Post-hoc Bonferroni-corrected t-tests were conducted when appropriate (p = 0.0125) to the true count (i.e., video recorded)
*p < .05
Fig. 3Percent error at each treadmill speed by device compared to the visual count
Pedometer and application reliability are presented as means and standard deviations of the percent error
| Application | Test (% error) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 20-Step (n = 11) | 40 Stair (n = 11) | Treadmill walking speed (n = 11) | Treadmill running speed (n = 11) | Free-living (n = 18) | ||||||
| M | SD | M | SD | M | SD | M | SD | M | SD | |
| Moves | −29.09 | 39.55 | −45.45 | 46.26 | −68.85 | 41.75 | −45.12 | 47.32 | 39.8 | 29.8 |
| Accupedo | −24.55 | 53.73 | −5.68 | 8.78 | −49.80 | 41.94 | 1.33 | 27.59 | 21.5 | 20.4 |
| Runtastic | 10.91 | 68.48 | −3.14 | 9.75 | −29.00 | 43.564 | −4.24 | 29.54 | 34.5 | 63.6 |
| Pedometer | −7.23 | 20.90 | 11.0 | 4.34 | −8.43 | 25.33 | 8.66 | 12.04 | ||
A one-way repeated-measures ANOVA showed each application to be significantly different from the pedometer
| Application | Mean (SD) | Sig. ( |
|---|---|---|
| Pedometer | 26,466 (±12,795) | – |
| Accupedo | 20,619 (±12,259) | 0.000 |
| Moves | 19,213 (±12,822) | 0.000 |
| Runtastic | 23,723 (±16,386) | 0.004 |
Means and standard deviations were derived from all three days of the study. α = 0.05