Literature DB >> 26614530

Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

Rebecca E Geist1, Chase H DuBois2, Timothy C Nichols3, Melissa C Caughey4, Elizabeth P Merricks5, Robin Raymer5, Caterina M Gallippi6.   

Abstract

Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a poroelastic tissue-mimic and in vivo in dogs. The experimental design exploits calibrated flow rates and infusion durations of evaporated milk in tofu or heparinized autologous blood in dogs. The validation approach enables controlled comparisons of ASSH-derived bleeding rate (BR) and time to hemostasis (TTH) metrics. In tissue-mimicking experiments, halving the calibrated flow rate yielded ASSH-derived BRs that decreased by 44% to 48%. Furthermore, for calibrated flow durations of 5.0 minutes and 7.0 minutes, average ASSH-derived TTH was 5.2 minutes and 7.0 minutes, respectively, with ASSH predicting the correct TTH in 78% of trials. In dogs undergoing calibrated autologous blood infusion, ASSH measured a 3-minute increase in TTH, corresponding to the same increase in the calibrated flow duration. For a measured 5% decrease in autologous infusion flow rate, ASSH detected a 7% decrease in BR. These tissue-mimicking and in vivo preclinical experimental validation studies suggest the ASSH BR and TTH measures reflect bleeding dynamics.
© The Author(s) 2015.

Entities:  

Keywords:  ARFI; ASSH; acoustic radiation force; bleeding; dog; hemorrhage; hemostasis; tofu; ultrasound

Mesh:

Year:  2015        PMID: 26614530      PMCID: PMC5719486          DOI: 10.1177/0161734615617940

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  20 in total

1.  Multi-modality tissue-mimicking phantom for thermal therapy.

Authors:  Mark McDonald; Shanna Lochhead; Rajiv Chopra; Michael J Bronskill
Journal:  Phys Med Biol       Date:  2004-07-07       Impact factor: 3.609

Review 2.  A review of tissue substitutes for ultrasound imaging.

Authors:  Martin O Culjat; David Goldenberg; Priyamvada Tewari; Rahul S Singh
Journal:  Ultrasound Med Biol       Date:  2010-06       Impact factor: 2.998

3.  Detectability of small blood vessels with high-frequency power Doppler and selection of wall filter cut-off velocity for microvascular imaging.

Authors:  Stephen Z Pinter; James C Lacefield
Journal:  Ultrasound Med Biol       Date:  2009-04-25       Impact factor: 2.998

4.  Managing risk of complications at femoral vascular access sites in percutaneous coronary intervention.

Authors:  Nakia Merriweather; Linda M Sulzbach-Hoke
Journal:  Crit Care Nurse       Date:  2012-10       Impact factor: 1.708

5.  Association between bleeding events and in-hospital mortality after percutaneous coronary intervention.

Authors:  Adnan K Chhatriwalla; Amit P Amin; Kevin F Kennedy; John A House; David J Cohen; Sunil V Rao; John C Messenger; Steven P Marso
Journal:  JAMA       Date:  2013-03-13       Impact factor: 56.272

Review 6.  Guidelines on the assessment of bleeding risk prior to surgery or invasive procedures. British Committee for Standards in Haematology.

Authors:  Y L Chee; J C Crawford; H G Watson; M Greaves
Journal:  Br J Haematol       Date:  2008-03       Impact factor: 6.998

Review 7.  The level of laboratory testing required for diagnosis or exclusion of a platelet function disorder using platelet aggregation and secretion assays.

Authors:  Diego Mezzano; Teresa Quiroga; Jaime Pereira
Journal:  Semin Thromb Hemost       Date:  2009-04-30       Impact factor: 4.180

8.  Usefulness of PFA-100 testing in the diagnostic screening of patients with suspected abnormalities of hemostasis: comparison with the bleeding time.

Authors:  G M Podda; P Bucciarelli; F Lussana; A Lecchi; M Cattaneo
Journal:  J Thromb Haemost       Date:  2007-12       Impact factor: 5.824

9.  Measurement of volume flow in the human common femoral artery using a duplex ultrasound system.

Authors:  P Lewis; J V Psaila; W T Davies; K McCarty; J P Woodcock
Journal:  Ultrasound Med Biol       Date:  1986-10       Impact factor: 2.998

Review 10.  A review of current methods for assessing hemostasis in vivo and introduction to a potential alternative approach.

Authors:  Mallory R Scola; Leslie M Baggesen; Tim C Nichols; Nigel S Key; Caterina M Gallippi
Journal:  Thromb Res       Date:  2012-03-08       Impact factor: 3.944

View more
  1 in total

1.  Carotid Plaque Fibrous Cap Thickness Measurement by ARFI Variance of Acceleration: In Vivo Human Results.

Authors:  Gabriela Torres; Tomasz J Czernuszewicz; Jonathon W Homeister; Mark A Farber; Melissa C Caughey; Caterina M Gallippi
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.