Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenoses.

M Koplay1, H Erdogan2, A Avci3, M Sivri2, K Demir3, I Guler2, L S Demir4, Y Paksoy2.   

Abstract

PURPOSE: "Flash Spiral" imaging is a new prospective ECG-triggered spiral scan mode that uses a very high-pitch for coronary computed tomography angiography (CTA). This enables complete image acquisition within one cardiac cycle with a very low radiation exposure. The aim of this study was to investigate the diagnostic accuracy, image quality, and effective radiation dose of prospectively ECG-triggered high-pitch spiral method (Flash spiral mode) of coronary CTA using dual-source technology for the evaluation of coronary artery stenoses.
MATERIAL AND METHODS: The study included 186 consecutive patients (115men, 71women; mean age: 53.37 years) who underwent coronary CTA. Coronary CTA was performed with a 128×2-slice dual-source CT (Somatom Definition Flash, Siemens, Germany) using a prospectively ECG-triggered high-pitch spiral mode. Patients were divided into three groups according to heart rate (≤65bpm, 66-75bpm, ≥76bpm) and body mass index (BMI) (20-24kg/m(2), 25-29kg/m(2), 30-34kg/m(2)) values. The correlation between heart rates, image quality and BMI values are investigated. A four-point scale (1=excellent, 4=poor/non-diagnostic) was used to rank the comparative image quality. Effective radiation doses were calculated. Also the correlation between radiation dose, sex and BMI values were investigated. In addition, diagnostic accuracy of CTA for detection of significant (≥50%) coronary artery stenoses was compared with invasive coronary angiography findings of 612vessel segments in 38patients. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rate were calculated.
RESULTS: A total of 2976coronary artery segments were present. Of all coronary artery segments, 2381 (80%) had an image quality score of 1, and 1.5% segments were rated as "poor/non-diagnostic". When the correlation between heart rate and image quality is investigated, there was a significant difference between ≤65bpm and ≥76bpm groups. However, there was no significant difference between ≤65bpm and 66-75bpm groups. The mean effective dose was found as 1.3mSv (min: 0.5, max: 2.4mSv). The correlation between effective radiation dose and BMI was moderate. However, the correlation between gender and radiation dose was significant. Sensitivity, specificity, negative predictive value and accuracy of coronary CTA on a per-vessel segment were 90.1%, 97.4%, 98.6%, and 96.5%, respectively.
CONCLUSIONS: Prospectively ECG-triggered high-pitch spiral mode coronary CTA provides high image quality and diagnostic accuracy, with very low radiation dose for evaluation and exclusion of coronary artery stenoses.
Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Coronary angiography; Dual source CT; High-pitch spiral acquisition; Image quality; Radiation dose

Mesh:

Year:  2015        PMID: 26612669     DOI: 10.1016/j.diii.2015.10.008

Source DB:  PubMed          Journal:  Diagn Interv Imaging        ISSN: 2211-5684            Impact factor:   4.026


  6 in total

1.  Image quality and diagnostic value of ultra low-voltage, ultra low-contrast coronary CT angiography.

Authors:  Chong-Fu Jia; Jie Zhong; Xin-Yi Meng; Xi-Xia Sun; Zhi-Qiang Yang; Yu-Jie Zou; Xiang-Yue Wang; Shuang Pan; Da Yin; Zhao-Qian Wang
Journal:  Eur Radiol       Date:  2019-03-19       Impact factor: 5.315

Review 2.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

3.  Improved assessment of mediastinal and pulmonary pathologies in combined staging CT examinations using a fast-speed acquisition dual-source CT protocol.

Authors:  Franziska M Braun; Veronica Holzner; Felix G Meinel; Marco Armbruster; Martina Brandlhuber; Birgit Ertl-Wagner; Wieland H Sommer
Journal:  Eur Radiol       Date:  2017-07-04       Impact factor: 5.315

4.  Second-generation motion correction algorithm improves diagnostic accuracy of single-beat coronary CT angiography in patients with increased heart rate.

Authors:  Junfu Liang; Ying Sun; Ziqing Ye; Yanchun Sun; Lei Xu; Zhen Zhou; Brian Thomsen; Jianying Li; Zhonghua Sun; Zhanming Fan
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

Review 5.  Low-Dose Radiation Advances in Coronary Computed Tomography Angiography in the Diagnosis of Coronary Artery Disease.

Authors:  Caryl E Richards; Daniel R Obaid
Journal:  Curr Cardiol Rev       Date:  2019

6.  Radiation dose and image quality of CT coronary angiography in patients with high heart rate or irregular heart rhythm using a 16-cm wide detector CT scanner.

Authors:  Marian Ondrejkovic; Dusan Salat; Daniel Cambal; Andrej Klepanec
Journal:  Medicine (Baltimore)       Date:  2022-09-16       Impact factor: 1.817