Literature DB >> 26611994

A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.

Z Li1, H H Hu2, J H Miller2, J P Karis3, P Cornejo2, D Wang4, J G Pipe4.   

Abstract

BACKGROUND AND
PURPOSE: A challenge with the T1-weighted postcontrast Cartesian spin-echo and turbo spin-echo brain MR imaging is the presence of flow artifacts. Our aim was to develop a rapid 2D spiral spin-echo sequence for T1-weighted MR imaging with minimal flow artifacts and to compare it with a conventional Cartesian 2D turbo spin-echo sequence.
MATERIALS AND METHODS: T1-weighted brain imaging was performed in 24 pediatric patients. After the administration of intravenous gadolinium contrast agent, a reference Cartesian TSE sequence with a scanning time of 2 minutes 30 seconds was performed, followed by the proposed spiral spin-echo sequence with a scanning time of 1 minutes 18 seconds, with similar spatial resolution and volumetric coverage. The results were reviewed independently and blindly by 3 neuroradiologists. Scores from a 3-point scale were assigned in 3 categories: flow artifact reduction, subjective preference, and lesion conspicuity, if any. The Wilcoxon signed rank test was performed to evaluate the reviewer scores. The t test was used to evaluate the SNR. The Fleiss κ coefficient was calculated to examine interreader agreement.
RESULTS: In 23 cases, spiral spin-echo was scored over Cartesian TSE in flow artifact reduction (P < .001). In 21 cases, spiral spin-echo was rated superior in subjective preference (P < .001). Ten patients were identified with lesions, and no statistically significant difference in lesion conspicuity was observed between the 2 sequences. There was no statistically significant difference in SNR between the 2 techniques. The Fleiss κ coefficient was 0.79 (95% confidence interval, 0.65-0.93).
CONCLUSIONS: The proposed spiral spin-echo pulse sequence provides postcontrast images with minimal flow artifacts at a faster scanning time than its Cartesian TSE counterpart.
© 2016 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26611994      PMCID: PMC7960179          DOI: 10.3174/ajnr.A4600

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  11 in total

1.  Fast spiral coronary artery imaging.

Authors:  C H Meyer; B S Hu; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

Review 2.  Factors influencing contrast in fast spin-echo MR imaging.

Authors:  R T Constable; A W Anderson; J Zhong; J C Gore
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

3.  Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction.

Authors:  G H Glover; E Schneider
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

4.  Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions.

Authors:  Kimberly D Brewer; James A Rioux; Ryan C N D'Arcy; Chris V Bowen; Steven D Beyea
Journal:  NMR Biomed       Date:  2009-07       Impact factor: 4.044

5.  Spiral spin-echo magnetic resonance imaging of the pelvis with spectrally and spatially selective radiofrequency excitation: comparison with fat-saturated fast spin-echo imaging.

Authors:  M E Yacoe; K C Li; L Cheung; C H Meyer
Journal:  Can Assoc Radiol J       Date:  1997-08       Impact factor: 2.248

6.  Analytical three-point Dixon method: With applications for spiral water-fat imaging.

Authors:  Dinghui Wang; Nicholas R Zwart; Zhiqiang Li; Michael Schär; James G Pipe
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

7.  Measuring signal-to-noise ratios in MR imaging.

Authors:  L Kaufman; D M Kramer; L E Crooks; D A Ortendahl
Journal:  Radiology       Date:  1989-10       Impact factor: 11.105

8.  Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1.

Authors:  R R Price; L Axel; T Morgan; R Newman; W Perman; N Schneiders; M Selikson; M Wood; S R Thomas
Journal:  Med Phys       Date:  1990 Mar-Apr       Impact factor: 4.071

9.  Simple proton spectroscopic imaging.

Authors:  W T Dixon
Journal:  Radiology       Date:  1984-10       Impact factor: 11.105

10.  A velocity k-space analysis of flow effects in echo-planar and spiral imaging.

Authors:  D G Nishimura; P Irarrazabal; C H Meyer
Journal:  Magn Reson Med       Date:  1995-04       Impact factor: 4.668

View more
  6 in total

1.  Opportunities in Interventional and Diagnostic Imaging by Using High-Performance Low-Field-Strength MRI.

Authors:  Adrienne E Campbell-Washburn; Rajiv Ramasawmy; Matthew C Restivo; Ipshita Bhattacharya; Burcu Basar; Daniel A Herzka; Michael S Hansen; Toby Rogers; W Patricia Bandettini; Delaney R McGuirt; Christine Mancini; David Grodzki; Rainer Schneider; Waqas Majeed; Himanshu Bhat; Hui Xue; Joel Moss; Ashkan A Malayeri; Elizabeth C Jones; Alan P Koretsky; Peter Kellman; Marcus Y Chen; Robert J Lederman; Robert S Balaban
Journal:  Radiology       Date:  2019-10-01       Impact factor: 11.105

2.  Spiral T1 Spin-Echo for Routine Postcontrast Brain MRI Exams: A Multicenter Multireader Clinical Evaluation.

Authors:  M B Ooi; Z Li; R K Robison; D Wang; A G Anderson; N R Zwart; A Bakhru; S Nagaraj; T Mathews; S Hey; J J Koonen; I E Dimitrov; H T Friel; Q Lu; M Obara; I Saha; H Wang; Y Wang; Y Zhao; M Temkit; H H Hu; T L Chenevert; O Togao; J A Tkach; U D Nagaraj; M C Pinho; R K Gupta; J E Small; M M Kunst; J P Karis; J B Andre; J H Miller; N K Pinter; J G Pipe
Journal:  AJNR Am J Neuroradiol       Date:  2020-02-06       Impact factor: 3.825

3.  Highly accelerated time-of-flight magnetic resonance angiography using spiral imaging improves conspicuity of intracranial arterial branches while reducing scan time.

Authors:  Tobias Greve; Nico Sollmann; Andreas Hock; Silke Hey; Velmurugan Gnanaprakasam; Marco Nijenhuis; Claus Zimmer; Jan S Kirschke
Journal:  Eur Radiol       Date:  2019-10-29       Impact factor: 5.315

4.  Diffusion-weighted MRI of ischemic stroke at 3T: Value of synthetic b-values.

Authors:  Thomas Sartoretti; Elisabeth Sartoretti; Michael Wyss; Manoj Mannil; Luuk van Smoorenburg; Barbara Eichenberger; Carolin Reischauer; Alex Alfieri; Christoph Binkert; Sabine Sartoretti-Schefer
Journal:  Br J Radiol       Date:  2021-02-17       Impact factor: 3.039

5.  Clinical feasibility of ultrafast intracranial vessel imaging with non-Cartesian spiral 3D time-of-flight MR angiography at 1.5T: An intra-individual comparison study.

Authors:  Thomas Sartoretti; Elisabeth Sartoretti; Árpád Schwenk; Luuk van Smoorenburg; Manoj Mannil; André Euler; Anton S Becker; Alex Alfieri; Arash Najafi; Christoph A Binkert; Michael Wyss; Sabine Sartoretti-Schefer
Journal:  PLoS One       Date:  2020-04-29       Impact factor: 3.240

6.  MaxGIRF: Image reconstruction incorporating concomitant field and gradient impulse response function effects.

Authors:  Nam G Lee; Rajiv Ramasawmy; Yongwan Lim; Adrienne E Campbell-Washburn; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2022-04-21       Impact factor: 3.737

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.