Literature DB >> 19382109

Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions.

Kimberly D Brewer1, James A Rioux, Ryan C N D'Arcy, Chris V Bowen, Steven D Beyea.   

Abstract

Functional MRI (fMRI) is of limited use in areas such as the orbitofrontal and inferior temporal lobes due to the presence of local susceptibility-induced field gradients (SFGs), which result in severe image artifacts. Several techniques have been developed to reduce these artifacts, the most common being the dual-echo spiral sequences (spiral-in/out and spiral-in/in). In this study, a new multiple spiral acquisition technique was developed, in which the later spiral acquisitions are acquired asymmetrically with the peak of a spin-echo causing increased R(2)-weighting but matched R(2)'-weighting. This sequence, called asymmetric spin-echo (ASE) spiral, has demonstrated significant improvements in minimizing the signal loss and increasing the image quality as well as optimal blood-oxygen-level-dependent (BOLD)-weighting. The ASE spiral is compared to conventional spiral-out using both signal-to-noise ratio (SNR) and whole brain fMRI activation volumes from a breath-hold task acquired at 4 Tesla. The ASE dual spiral has exhibited SNR increases of up to 300% in areas where strong SFGs are present. As a result, the ASE spiral is highly efficient for recovering lost activation in areas of SFGs, as demonstrated by a 16% increase in the total number of activated voxels over the whole brain. Post spin-echo ASE spiral images have decreasing SNR due to R(2) signal losses, however the increase in R(2)-weighting leads to a higher percentage of signal changes producing ASE spiral images with equivalent contrast-to-noise ratio (CNR) for each echo. The use of this sequence allows for recovery of BOLD activation in areas of SFG without sacrificing the CNR over the whole brain. Copyright (c) 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2009        PMID: 19382109     DOI: 10.1002/nbm.1380

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  6 in total

1.  Investigation of fMRI activation in the internal capsule.

Authors:  Jodie R Gawryluk; Erin L Mazerolle; Kimberley D Brewer; Steven D Beyea; Ryan C N D'Arcy
Journal:  BMC Neurosci       Date:  2011-06-14       Impact factor: 3.288

2.  A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.

Authors:  Z Li; H H Hu; J H Miller; J P Karis; P Cornejo; D Wang; J G Pipe
Journal:  AJNR Am J Neuroradiol       Date:  2015-11-26       Impact factor: 3.825

Review 3.  A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.

Authors:  Nicholas P Blockley; Valerie E M Griffeth; Aaron B Simon; Richard B Buxton
Journal:  NMR Biomed       Date:  2012-09-04       Impact factor: 4.044

4.  Functional MRI activation in white matter during the Symbol Digit Modalities Test.

Authors:  Jodie R Gawryluk; Erin L Mazerolle; Steven D Beyea; Ryan C N D'Arcy
Journal:  Front Hum Neurosci       Date:  2014-08-04       Impact factor: 3.169

5.  Clinical feasibility of ultrafast intracranial vessel imaging with non-Cartesian spiral 3D time-of-flight MR angiography at 1.5T: An intra-individual comparison study.

Authors:  Thomas Sartoretti; Elisabeth Sartoretti; Árpád Schwenk; Luuk van Smoorenburg; Manoj Mannil; André Euler; Anton S Becker; Alex Alfieri; Arash Najafi; Christoph A Binkert; Michael Wyss; Sabine Sartoretti-Schefer
Journal:  PLoS One       Date:  2020-04-29       Impact factor: 3.240

6.  White versus gray matter: fMRI hemodynamic responses show similar characteristics, but differ in peak amplitude.

Authors:  Leanne M Fraser; M Tynan Stevens; Steven D Beyea; Ryan C N D'Arcy
Journal:  BMC Neurosci       Date:  2012-08-01       Impact factor: 3.288

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.