Literature DB >> 26604472

Bite Force Evaluation of Conventional Plating System Versus Locking Plating System for Mandibular Fracture.

Kolli Yada Giri1, Puneet Sahu1, Sanjay Rastogi1, Ramakant Dandriyal1, Sunil Mall1, Aishwarya Pratap Singh1, Niranjana Prasad Indra B1, Himanshu Pratap Singh1.   

Abstract

AIMS AND
OBJECTIVES: To compare and evaluate the variation in recorded bite forces in patients with mandibular fractures undergoing open reduction and rigid internal fixation using standard 2.0 versus 2.0 mm locking miniplates.
MATERIALS AND METHODS: A prospective randomized study was conducted for the treatment of mandibular fractures. Twenty adult patients with 31 mandibular fractures requiring an open reduction and internal fixation were included in the study. The sample was divided into two groups depending upon whether the patients received 2.0 mm non-locking (standard) or 2.0 mm locking miniplates for rigid fixation respectively. Bite force was evaluated at 1st, 3rd and 6th week after the open reduction and rigid fixation using miniplates.
RESULTS: A statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. The results showed that amongst locking vs non-locking miniplates, the former showed a greater bite force enhancement when compared to baseline values(post-trauma).A comparison between 2nd day post-operative vs 6th week post-operative values showed a significant increase in bite force in Group 1 (non-locking) (p < 0.05) whereas the values Were highly significant (p < 0.001) in Group 2 (locking Plate).
CONCLUSION: The findings were suggestive that the efficacy of locking miniplates plate in mandibular fracture was superior in terms of bearing the masticatory loads during osteosynthesis of the fracture. However, the clinical results were almost similar to those seen with non-locking miniplate osteosynthesis.

Entities:  

Keywords:  Bite force; Bite meter; Locking plates; Non-locking plates

Year:  2015        PMID: 26604472      PMCID: PMC4648785          DOI: 10.1007/s12663-015-0764-7

Source DB:  PubMed          Journal:  J Maxillofac Oral Surg        ISSN: 0972-8270


  23 in total

1.  Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates.

Authors:  Richard H Haug; Chad C Street; Michele Goltz
Journal:  J Oral Maxillofac Surg       Date:  2002-11       Impact factor: 1.895

2.  Prospective randomized clinical trial comparing bite force in 2-mm locking plates versus 2-mm standard plates in treatment of mandibular fractures.

Authors:  Mohit Agarwal; Shadab Mohammad; Rakesh K Singh; Vibha Singh
Journal:  J Oral Maxillofac Surg       Date:  2011-01-26       Impact factor: 1.895

3.  Bite forces in patients after treatment of mandibular angle fractures with miniplate osteosynthesis according to Champy.

Authors:  K L Gerlach; A Schwarz
Journal:  Int J Oral Maxillofac Surg       Date:  2002-08       Impact factor: 2.789

4.  [Mandibular osteosynthesis according to the Michelet technic. I. Biomechanical bases].

Authors:  M Champy; J P Lodde; J H Jaeger; A Wilk
Journal:  Rev Stomatol Chir Maxillofac       Date:  1976 Apr-May

5.  Transoral 2.0-mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: a prospective study.

Authors:  Ayman Chritah; Stewart K Lazow; Julius R Berger
Journal:  J Oral Maxillofac Surg       Date:  2005-12       Impact factor: 1.895

6.  [Mandibular osteosynthesis and compression].

Authors:  M Champy; J P Loddé; D Grasset; D Muster; A Mariano
Journal:  Ann Chir Plast       Date:  1977

7.  Infections associated with locking reconstruction plates: a retrospective review.

Authors:  David Kirkpatrick; Rahul Gandhi; Joseph E Van Sickels
Journal:  J Oral Maxillofac Surg       Date:  2003-04       Impact factor: 1.895

8.  [Study of stresses in the fractured mandible in man. Theoretical measurement and verification by extensometric gauges in situ].

Authors:  M Champy; J P Lodde
Journal:  Rev Stomatol Chir Maxillofac       Date:  1977

9.  A comparative review of 266 mandibular fractures with internal fixation using rigid (AO/ASIF) plates or mini-plates.

Authors:  M A Kuriakose; M Fardy; M Sirikumara; D W Patton; A W Sugar
Journal:  Br J Oral Maxillofac Surg       Date:  1996-08       Impact factor: 1.651

10.  A comparative biomechanical evaluation of mandibular condyle fracture plating techniques.

Authors:  Luciana Asprino; Simonides Consani; Márcio de Moraes
Journal:  J Oral Maxillofac Surg       Date:  2006-03       Impact factor: 1.895

View more
  5 in total

1.  Three-dimensional versus standard miniplate, lag screws versus miniplates, locking plate versus non-locking miniplates: Management of mandibular fractures, a systematic review and meta-analysis.

Authors:  Patiguli Wusiman; Dilidaer Taxifulati; Li Weidong; Adili Moming
Journal:  J Dent Sci       Date:  2019-01-14       Impact factor: 2.080

2.  Comparative study of outcomes between locking plates and three-dimensional plates in mandibular fractures.

Authors:  Shaikh Amjad; M D Kalim Ansari; Syed S Ahmad; Tabishur Rahman
Journal:  Natl J Maxillofac Surg       Date:  2020-12-16

3.  Is "Bite force" a reliable parameter to compare masticatory efficiency restoration following ORIF of anterior mandibular fractures?

Authors:  Shital Patel; Kruna Bhimani; Roma Narsingyani; Zenish Bhatti; Rajan Savani
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-09

4.  Assessment of Lingual Stability in Mandible Fracture: Monocortical Versus Bicortical Fixation Using FEM Analysis.

Authors:  Udupikrishna Joshi; Manju Kurakar
Journal:  J Maxillofac Oral Surg       Date:  2017-12-16

Review 5.  Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis.

Authors:  José Cristiano Ramos Glória; Ighor Andrade Fernandes; Esmeralda Maria da Silveira; Glaciele Maria de Souza; Ricardo Lopes Rocha; Endi Lanza Galvão; Saulo Gabriel Moreira Falci
Journal:  Int Arch Otorhinolaryngol       Date:  2017-07-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.