Literature DB >> 26601014

Handheld, rapidly switchable, anterior/posterior segment swept source optical coherence tomography probe.

Derek Nankivil1, Gar Waterman1, Francesco LaRocca1, Brenton Keller1, Anthony N Kuo2, Joseph A Izatt3.   

Abstract

We describe the first handheld, swept source optical coherence tomography (SSOCT) system capable of imaging both the anterior and posterior segments of the eye in rapid succession. A single 2D microelectromechanical systems (MEMS) scanner was utilized for both imaging modes, and the optical paths for each imaging mode were optimized for their respective application using a combination of commercial and custom optics. The system has a working distance of 26.1 mm and a measured axial resolution of 8 μm (in air). In posterior segment mode, the design has a lateral resolution of 9 μm, 7.4 mm imaging depth range (in air), 4.9 mm 6dB fall-off range (in air), and peak sensitivity of 103 dB over a 22° field of view (FOV). In anterior segment mode, the design has a lateral resolution of 24 μm, imaging depth range of 7.4 mm (in air), 6dB fall-off range of 4.5 mm (in air), depth-of-focus of 3.6 mm, and a peak sensitivity of 99 dB over a 17.5 mm FOV. In addition, the probe includes a wide-field iris imaging system to simplify alignment. A fold mirror assembly actuated by a bi-stable rotary solenoid was used to switch between anterior and posterior segment imaging modes, and a miniature motorized translation stage was used to adjust the objective lens position to correct for patient refraction between -12.6 and + 9.9 D. The entire probe weighs less than 630 g with a form factor of 20.3 x 9.5 x 8.8 cm. Healthy volunteers were imaged to illustrate imaging performance.

Entities:  

Keywords:  (080.3620) Lens system design; (110.4500) Optical coherence tomography; (170.0110) Imaging systems; (170.4460) Ophthalmic optics and devices; (170.4470) Ophthalmology; (170.5755) Retina scanning

Year:  2015        PMID: 26601014      PMCID: PMC4646558          DOI: 10.1364/BOE.6.004516

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  15 in total

1.  Real-time optical coherence tomography of the anterior segment at 1310 nm.

Authors:  S Radhakrishnan; A M Rollins; J E Roth; S Yazdanfar; V Westphal; D S Bardenstein; J A Izatt
Journal:  Arch Ophthalmol       Date:  2001-08

2.  Simultaneous swept source optical coherence tomography of the anterior segment and retina using coherence revival.

Authors:  Al-Hafeez Dhalla; Derek Nankivil; Theresa Bustamante; Anthony Kuo; Joseph A Izatt
Journal:  Opt Lett       Date:  2012-06-01       Impact factor: 3.776

3.  Wide-field schematic eye models with gradient-index lens.

Authors:  Alexander V Goncharov; Chris Dainty
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-08       Impact factor: 2.129

4.  A pyramid approach to subpixel registration based on intensity.

Authors:  P Thévenaz; U E Ruttimann; M Unser
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

5.  Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system.

Authors:  Francesco Larocca; Derek Nankivil; Sina Farsiu; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2013-10-01       Impact factor: 3.732

6.  Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser.

Authors:  Thomas Klein; Wolfgang Wieser; Christoph M Eigenwillig; Benjamin R Biedermann; Robert Huber
Journal:  Opt Express       Date:  2011-02-14       Impact factor: 3.894

7.  True color scanning laser ophthalmoscopy and optical coherence tomography handheld probe.

Authors:  Francesco LaRocca; Derek Nankivil; Sina Farsiu; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2014-08-27       Impact factor: 3.732

8.  Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.

Authors:  Chen D Lu; Martin F Kraus; Benjamin Potsaid; Jonathan J Liu; Woojhon Choi; Vijaysekhar Jayaraman; Alex E Cable; Joachim Hornegger; Jay S Duker; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2013-12-20       Impact factor: 3.732

9.  Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 kHz imaging with a 100 kHz source.

Authors:  Derek Nankivil; Al-Hafeez Dhalla; Niklas Gahm; Kevin Shia; Sina Farsiu; Joseph A Izatt
Journal:  Opt Lett       Date:  2014-07-01       Impact factor: 3.776

10.  Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation.

Authors:  Stephanie J Chiu; Xiao T Li; Peter Nicholas; Cynthia A Toth; Joseph A Izatt; Sina Farsiu
Journal:  Opt Express       Date:  2010-08-30       Impact factor: 3.894

View more
  18 in total

1.  Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.

Authors:  Ryan P McNabb; James Polans; Brenton Keller; Moseph Jackson-Atogi; Charlene L James; Robin R Vann; Joseph A Izatt; Anthony N Kuo
Journal:  Biomed Opt Express       Date:  2018-12-21       Impact factor: 3.732

2.  Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography.

Authors:  Joseph D Malone; Mohamed T El-Haddad; Ivan Bozic; Logan A Tye; Lucas Majeau; Nicolas Godbout; Andrew M Rollins; Caroline Boudoux; Karen M Joos; Shriji N Patel; Yuankai K Tao
Journal:  Biomed Opt Express       Date:  2016-12-12       Impact factor: 3.732

3.  Wide-field retinal optical coherence tomography with wavefront sensorless adaptive optics for enhanced imaging of targeted regions.

Authors:  James Polans; Brenton Keller; Oscar M Carrasco-Zevallos; Francesco LaRocca; Elijah Cole; Heather E Whitson; Eleonora M Lad; Sina Farsiu; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2016-12-02       Impact factor: 3.732

4.  Constant linear velocity spiral scanning for near video rate 4D OCT ophthalmic and surgical imaging with isotropic transverse sampling.

Authors:  Oscar M Carrasco-Zevallos; Christian Viehland; Brenton Keller; Ryan P McNabb; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2018-09-28       Impact factor: 3.732

5.  Real-time visualization and interaction with static and live optical coherence tomography volumes in immersive virtual reality.

Authors:  Mark Draelos; Brenton Keller; Christian Viehland; Oscar M Carrasco-Zevallos; Anthony Kuo; Joseph Izatt
Journal:  Biomed Opt Express       Date:  2018-05-30       Impact factor: 3.732

6.  Effective bidirectional scanning pattern for optical coherence tomography angiography.

Authors:  Myeong Jin Ju; Morgan Heisler; Arman Athwal; Marinko V Sarunic; Yifan Jian
Journal:  Biomed Opt Express       Date:  2018-04-25       Impact factor: 3.732

7.  Advances in Whole-Eye Optical Coherence Tomography Imaging.

Authors:  Anthony N Kuo; Ryan P McNabb; Joseph A Izatt
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019-03-25

8.  Combined anterior segment OCT and wavefront-based autorefractor using a shared beam.

Authors:  Marco Ruggeri; Giulia Belloni; Yu-Cherng Chang; Heather Durkee; Ettore Masetti; Florence Cabot; Sonia H Yoo; Arthur Ho; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2021-10-06       Impact factor: 3.562

9.  Robotically aligned optical coherence tomography with 5 degree of freedom eye tracking for subject motion and gaze compensation.

Authors:  Pablo Ortiz; Mark Draelos; Christian Viehland; Ruobing Qian; Ryan P McNabb; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2021-11-08       Impact factor: 3.562

10.  Contactless optical coherence tomography of the eyes of freestanding individuals with a robotic scanner.

Authors:  Mark Draelos; Pablo Ortiz; Ruobing Qian; Christian Viehland; Ryan McNabb; Kris Hauser; Anthony N Kuo; Joseph A Izatt
Journal:  Nat Biomed Eng       Date:  2021-07-12       Impact factor: 29.234

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.