Solid tumours often present regions with severe oxygen deprivation (hypoxia), which are resistant to both chemotherapy and radiotherapy. Increased radiosensitivity as a function of the oxygen concentration is well described for X-rays. It has also been demonstrated that radioresistance in anoxia is reduced using high-LET radiation rather than conventional X-rays. However, the dependence of the oxygen enhancement ratio (OER) on radiation quality in the regions of intermediate oxygen concentrations, those normally found in tumours, had never been measured and biophysical models were based on extrapolations. Here we present a complete survival dataset of mammalian cells exposed to different ions in oxygen concentration ranging from normoxia (21%) to anoxia (0%). The data were used to generate a model of the dependence of the OER on oxygen concentration and particle energy. The model was implemented in the ion beam treatment planning system to prescribe uniform cell killing across volumes with heterogeneous radiosensitivity. The adaptive treatment plans have been validated in two different accelerator facilities, using a biological phantom where cells can be irradiated simultaneously at three different oxygen concentrations. We thus realized a hypoxia-adapted treatment plan, which will be used for painting by voxel of hypoxic tumours visualized by functional imaging.
Solid tumours often present regions with severe oxygen deprivation (hypoxia), which are resistant to both chemotherapy and radiotherapy. Increased radiosensitivity as a function of the oxygen concentration is well described for X-rays. It has also been demonstrated that radioresistance in anoxia is reduced using high-LET radiation rather than conventional X-rays. However, the dependence of the oxygen enhancement ratio (OER) on radiation quality in the regions of intermediate oxygen concentrations, those normally found in tumours, had never been measured and biophysical models were based on extrapolations. Here we present a complete survival dataset of mammalian cells exposed to different ions in oxygen concentration ranging from normoxia (21%) to anoxia (0%). The data were used to generate a model of the dependence of the OER on oxygen concentration and particle energy. The model was implemented in the ion beam treatment planning system to prescribe uniform cell killing across volumes with heterogeneous radiosensitivity. The adaptive treatment plans have been validated in two different accelerator facilities, using a biological phantom where cells can be irradiated simultaneously at three different oxygen concentrations. We thus realized a hypoxia-adapted treatment plan, which will be used for painting by voxel of hypoxic tumours visualized by functional imaging.
Hypoxia is a feature of most tumours, albeit with variable incidence and severity within
a given patient population1. It is a negative prognostic and predictive
factor owing to its multiple contributions to resistance to cell death (chemoresistance,
radioresistance), angiogenesis, vasculogenesis, invasiveness, metastasis, altered
metabolism and genomic instability2.Hypoxia-induced radiation resistance is generally acknowledged as a major limiting factor
for tumour control in radiotherapy3. The increase of radioresistance is
quantified by the oxygen enhancement ratio (OER), i.e., the ratio of iso-effective doses
in hypoxic and fully oxygenated conditions:where pO defines a given level of hypoxia, i.e. the oxygen
concentration (usually expressed as a partial pressure in %), S0 is a
given cell survival fraction and D are corresponding radiation doses (usually
expressed in Gy). Several in vitro studies demonstrated that for most of the cell
lines irradiated with X-rays in anoxia
(pO = 0) the OER is approximately
3.Charged particle therapy is a cutting-edge radiotherapy technique which, among several
physical and radiobiological peculiar advantages45, has the potential
of a reduced OER. This is due to the special features of this type of radiation,
characterized by a high linear energy transfer (LET, usually expressed in
keV/μm), i.e. by dense ionization tracks, opposite to sparsely ionizing
photons commonly used in radiotherapy6. The resulting direct DNA damage
produces a high relative biological effectiveness (RBE) compared to photons, and is less
sensitive to the presence of molecular oxygen. It was indeed demonstrated that OER
decreases with LET, dropping to almost 1 over a few hundreds of keV/μm78. The OER reduction is generally attributed to recombination of the
radiation-induced free radicals or production of “oxygen in the
track”9101112. Particle therapy is therefore
assumed to be especially effective against hypoxic tumours13, and can
specifically target cancer stem cell subpopulations in hypoxic niches within the
tumour14. A clinical study on radiotherapy of hypoxic uterine cervix
cancers was performed using passively modulated carbon ions in Japan15.
The results support the hypothesis that hypoxia is less important in radiotherapy using
heavy ions compared to conventional photons, although the need for more research was
pointed out in order to improve local control.OER as a function of LET has been extensively measured, but only for fully anoxic
conditions or for uncontrolled pO78. However,
tumours and normal tissues have oxygen concentrations in between 21% and 0%, a condition
known as physioxia: 3%–7.4% in normal tissues, 0.3%–4% in
tumours16. The regions at intermediate hypoxia are those more
important in determining tumour response to radiotherapy17. Moreover, the
normal LET distribution in a typical carbon ion irradiation is exceeding
100 keV/μm in a very small region of the target only. For this
reason it is important to optimize the treatment planning system (TPS) accounting for
both LET and pO. This is possible for particle therapy using
the active scanning dose delivery technique18. However, up to now,
particle therapy TPS was always limited to optimization of the RBE-weighted dose19, without including any hypoxic effect, and especially any intra-tumour
heterogeneous sensitivity.The dependence on OER from pO was measured already many years
ago for X-rays20 and can be described by the Alper and Howard-Flanders
formula, derived from modeling a Michaelis-Menten kinetics mechanismwhere m is a maximum effect and k a concentration corresponding to a
half-maximum sensitization, i.e. the pO value corresponding to
the flex point of the sigmoid-shaped curve.Modern functional imaging provides quantitative information on hypoxia in
vivo2122, allowing intra-tumour heterogeneous mapping,
especially through PET biomarker tracers, e.g. with 18F labelled
nitroimidazoles such as misonidazole (18F-MISO), azomycin-arabinoside
(18F-AZA) and the nucleoside analog
(18F-HX4)23. Other non-invasive methods are
recently emerging and include functional magnetic resonance imaging24,
fluorescent markers2526, Cherenkov radiation27. Despite
the large amount of preclinical research in this field, a real use of hypoxia
information in clinics is still missing28. Clinical implementation needs
adaptive TPS29, identification of tumour sub-targets and methods for
their selective irradiation. Intra-tumour heterogeneities can be targeted with a
non-uniform dose prescription in the TPS, based on sub-volume boosting or
dose-painting by numbers30. The reduced OER at high LET can be
exploited in charged particle therapy using either protons31 or heavy
ions32 with TPS where, by prescription, the high-LET components of
the beam are constrained in the hypoxic regions: the so-called LET-painting. To
integrate the information in the TPS, it is necessary to attain a full description of
OER as a function of LET and pO. A few models have been
previously reported33343536, but the lack of experimental data did
not allow their complete verification.Here we develop an ion TPS optimized on the cell killing of the entire heterogeneous
tumour volume (kill-painting), considering the intermediate levels of oxygenation
and taking fully into account the biological advantages of ion beams, as well as the
flexibility of the active scanning dose delivery system. We present the first set of
systematic in vitro measurements of OER at intermediate values of oxygen
concentration and LET. We then use the experimental data for validating a model
describing the OER dependence versus pO and LET, which we
implement in the ion TPS. Finally, we verify our new TPS approach predictions with
measurements on extended heterogeneous targets including mammalian cells at different
oxygen concentrations.
Results
Survival data collection
We performed clonogenic survival rate measurements on CHO cells at 5 different
oxygen concentrations using photons and different ions at different
dose-averaged LET , with a special focus in the
region of maximum gradient of the OER
(70–150 keV/μm). The measurements were done
at the HIMAC accelerator of the National Institute for Radiological Sciences
(NIRS) in Japan and were integrated with previous measurements performed in
fully anoxic condition at the SIS18 of the GSI Helmholtz Center and the
Heidelberg Ion Therapy (HIT) synchrotrons in Germany37, using 2
different hypoxic chambers and ions of different mass and velocity.Figure 1 shows examples of the measured survival data. The
different filling of the points represents the three independent sets of
measurements, while error bars are standard deviations obtained by averaging the
three technical replicates. Each survival curve was fitted by the usual
linear-quadratic (LQ) equation
Figure 1
Oxic and hypoxic survival rates at different LET.
A subset of the measured survival curves used to extract OER points, for
different LET and pO values, including the
corresponding (contemporary) oxic measurement. Each curve is obtained by
fitting three independent measurements (different symbol colors), except the
hypoxic curve in panel d, where only two measurements were considered.
with fitting parameters α and β, by pooling
all the biological replicates in a single set, thus accounting for the
biological variability and obtaining a single set of fitting parameters (see
Supplementary Information (SI)
for details).The OER values (eq. 1) were then calculated using the
formulawhere the index ox defines parameters extracted from the corresponding
normoxic survival curve (performed on the same day, see SI). The full dataset is shown in Table S1 together with all the
information related to the experimental conditions and the corresponding
OER(10%) values.
OER model description and verification
We extended the Alper and Howard-Flanders (eq. 2)
model20 by including the LET dependence. The LET variable is
initially introduced in fully anoxic conditions according to an empirical
formula developed in analogy to the classical formalism for
pO dependence, where an additional exponential
parameter (γ) takes into account the steeper dependence of
the OER on the LET variable. This approach for the LET dependence is empirical,
but the use of this formalism can be mechanistically justified within the
oxygen-in-the-track theory, where the enhancement of sensitivity for
rising LET is attributed to the nanoscopic production of molecular oxygen in
highly dense tracks38, which is supralinear with respect to
LET.With this approach, the LET dependence in anoxic condition can be written aswhere M, the maximum possible effect for enhanced radioresistance,
corresponds to an asymptotic level of low LET (X-rays) and oxygen concentration.
The parameters a and γ are fitting parameters;
a1/ defines the LET value
corresponding to half maximum of the sensitization (the flex point of the LET
profile). We assume a and γ as tissue-independent
parameters related to the radiation quality only. This is similar to what is
observed for the RBE, whose absolute values are strongly tissue-dependent, but
the position of the maximum on the LET scale is almost constant39.For fitting these parameters, we initially used the extensive dataset measured at
NIRS for V79 cells at
pO = 0%8
and subsequently adapted it to the specific cell line subject of this study
(CHO), leading to
a = 8.27∙105
(keV/μm)γ and
γ = 3.0. The maximum OER M was set to
2.7, based on our recent X-ray measurements on CHO cells40. This
slightly lower value presented by these cells may be due to their specific
characteristics in terms, e.g., of repair capabilities and
scavengers´concentration.The oxygen concentration dependence can then be introduced into eq. 5 using the Alper formula in eq. 2
(Fig. 2):
Figure 2
OER model.
Two-dimensional semiempirical description of the OER dependence on LET and
pO proposed in this work.
where the parameter b = k, is set to
0.25% according to a recent X-ray data parameterization41.Equation 6 describes the experimental data (Fig. 3) very well without any additional fitting parameter. The
agreement is particularly good in the region of intermediate LET
(50–150 keV/μm), where the surface shows its
maximum gradient (Fig. 2), and which is more relevant for
clinical applications. The few deviating points at very high LET are occurring
in a region where probably the track-segment conditions are not fulfilled, or a
high contamination of nuclear fragments is reducing the actual LET of the
beam.
Figure 3
OER model verification.
Collection of all OER measurements compared to model surface cuts.
The kill-painting approach
The OER model (Fig. 2, eq. 6) is then
used for implementing an adaptive treatment planning for hypoxic tumours in
TRiP984243, the research TPS on which most commercial
systems currently used for C-ion therapy in several facilities in Europe and
China are based. Since the dose dependence of OER is small41,
especially for high LET33, the average value , similar to
OER(S = 0.1), can be used as a dose modifying
factor at any survival level and properly introduced in the TPS.While the mathematical details of the OER driven optimization in TRiP98 are
available in the M&M section, we want to stress here that the
optimization quantity is not anymore an RBE-weighted dose, but rather directly
the surviving fraction S. The method is therefore distinct from dose- or
LET-painting, where plan constraints (a given LET or dose) are prescribed by
construction, e.g. by applying dose ramps32 and we chose to call
it a “kill-painting”44.An example is shown in Fig. 4, where the survival profile
of a heterogeneous phantom, having a cellular target at 3 different levels of
oxygenation (as illustrated in panel 4a) is plotted for a forward plan (panel
4b), optimized disregarding the oxygen effect, and for an inverse plan (panel
4c), where the oxygen concentration is specifically included in the
optimization. In the panel 4b, the highly inhomogeneous survival is related to
the size of the target, which “dilutes” the LET
distribution. In a conventional plan, lower LET values are in the target center,
where we placed the maximum hypoxia level, as it indeed generally occurs in real
tumours. In the panel 4c, the prescribed survival level is restored and
uniformly distributed all over the target, at a price of a slight increase of
the dose in the entrance channel (corresponding to about 20%).
Figure 4
Kill-painting.
Planned survival rates (values in legend) on the differently oxygenated
target shown on panel (a), without (b) and with (c)
considering the inhomogeneous oxygen concentration in the optimization.
Extended target irradiation
We tested the new feature of our TPS with dedicated experiments on extended
biological phantoms, both for its predictive capabilities (forward plans) as
well as for its adaptive features (inverse planning), in recovering a uniform
survival level. Figure 5e shows the experimental setup,
where cellular samples on their turn at different oxygen concentrations can be
irradiated with two opposite beams (see M&M for details).
Figure 5
Experimental verification setup.
Single (a) and triple (b) hypoxic chambers used for experiments
in Germany (GSI and HIT); chamber set used at NIRS for survival curve
experiments (c), holding several specific Petri dishes (d);
“hypoxic phantom” (e) used for all the
extended target measurements. The GSI triple chambers (b) were used
both in Japan and Germany, and additional measurement points in normoxic
regions were collected with normal tissue culture flasks (TCF).
a) Forward planning (Expected Survival)
In Fig. 6 we show the verification of the non-optimized
plan. The forward planning test was performed at the HIMAC accelerator at
NIRS with superimposition of two opposite passively-modulated carbon beams.
The expected steep change in survival, from approximately 2% in normoxia up
to almost 30% in anoxia, is reproduced by the measurements in the different
regions of the phantom.
Figure 6
Non-optimized plan verification
Extended target survival measurements
performed at HIMAC compared with the calculation by our new TPS version. A beam of 290 MeV/u 12C-ions was used from both
sides, passively modulated in a SOBP of 6 cm, on a phantom of
18 cm. Dose in the target was recalculated from the oxic control
as 9.5 Gy (RBE) (see M&M).
b) Inverse planning (OER- Optimization)
In Fig. 7 we show the verification of the optimized
plan performed at the SIS18 accelerator at GSI using carbon ions delivered
by raster scanning and active energy modulation. The dashed line represents
the corresponding survival prediction for an irradiation with a plan
optimized disregarding the different oxygenation conditions, as in Fig. 6. The full red line is instead the result of the
new calculation taking into account the intra-target heterogeneity in
radiosensitivity, using kill-painting. The measured survival is
approximately constant all over the target at different oxygen
concentrations. The plan is correctly predicting the flat survival in the
target region and the slight increased cell death in the beam entrance
channel due to the increased dose.
Figure 7
OER optimized plan verification.
Comparison of expected survival in an OER optimized plan with experimental
results, performed at GSI. An actively scanned 12C ion beam,
composed of 17 monoenergetic slices ranging from 234.64 to
155.26 MeV/u was used from both sides. The target length was
6 cm on a phantom of 16 cm. The beam was optimized
with a prescribed survival level in the target of 0.1, corresponding to a
RBE-weighted dose of 6.5 Gy (RBE) in normoxia. RBE-weighted dose
in the entrance is 2.8 Gy(RBE). The dashed curve represents the
expected survival across the phantom, when a normoxic plan is applied
(similar to previous figure). Absolute measured and calculated data are
shown, with no recalculation adjustment applied.
We performed several additional experiments (see SI) for obtaining proper normoxic
controls on the whole bio-phantom used. We irradiated normoxic cells, placed
all along the target volume with a normoxic plan (Fig. S2a), to check the response of the
phantom under the two fields, without any oxygen effect. Then we irradiated
with an OER optimized plan normoxic cells placed in the same position where
the anoxic ones were situated, i.e. at the center of the target (Fig. S2b), to verify the pure
effect of the RBE-weighted dose of the modified plan. Furthermore, we
compared the radiosensitivities of the different cell systems used (Fig. S3).We finally analysed and compared the contributions of the two fields in the
two different plans (see Fig.
S4), showing how the optimization redistributes the particle fluences
in the different energy slices. One of the effects of this redistribution is
that the in the center of the target increases
from 55 to 75 keV/μm. This shows that both dose and
LET variations are contributing to the increased effectiveness achieved by
the kill-painting.
Therapeutic improvement assessment
The kill-painting approach described here is able to optimize a plan in particle
therapy for a heterogeneous tumour target, i.e. with variable radiosensitivity.
This is done by correctly predicting the heterogeneous response, voxel by voxel,
and adapting the irradiation fields to restore a uniform survival, at the price
of a slight increase of dose in the entrance channels, which is kept minimal by
the optimization.A quantitative estimation of the overall effect of the OER-optimized plan,
considering also the increased dose in the entrance channel, is shown in Fig. 8. The tumour control probability (TCP) for the
idealized heterogeneous target phantom used in our experiments (Fig. 5e), assuming a radiotherapy course in n fractions
is:
Figure 8
Kill-painting therapeutic improvement.
Tumour control probability computed as a function of a biologically
isoeffective dose (BED) for the two different plans. The BED is computed in
the entrance channel at 25 mm depth, in order to indicate a
similar damage to the normal tissue, after application of several fractions
of each plan to the target.
where S are the survival levels in each voxel i
of the tumour after each dose fraction, N is the total number of voxels
in the tumour, vi are the voxel volumes
(2 × 2 × 2 mm3
in this case, considering the pseudo-CT calculation grid used) and
ρ the corresponding local number of
cells per unit volume.For comparison with the normoxic plan, we consider irradiation schedules giving
the same biologically effective dose (BED) in the entrance channel. The BED is a
conventional isoeffective quantity based on the LQ eq. 3,
and can be computed by the Fowler formula45where E = −log S(n), d
is the dose per fraction, S(n) the overall survival after n
fractions and α, β are the parameters of a
reference survival curve for the specific tissue (eq. 3).
For equal fractions
E = −n log
(S), thus a different number of fractions gives the same BED at a
given depth in the normal tissue for the normoxic and adapted plan. The
isoeffective number of fractions n’ for the normoxic plan,
giving the same BED of n fractions of the OER-optimized plan in the voxel
k can be computed aswhere S is the survival level, for each plan, in a
given voxel k of the entrance channel and
n’ < n.In Fig. 8 we show the TCP (eq. 7) of
the two plans as a function of the BED, where the BED is sampled at an average
depth z = 25 mm, considering a
constant
ρ = 104 cells/mm3.
The ratio of the BED providing the same 50% TCP for the two plans is 1.78. We
therefore expect a significant improvement in local control using an
OER-optimized plan for hypoxic tumours also in vivo, at the same risk of
normal tissue complications (BED in the entrance channel).
Discussion
Potential extensions and limitations
The adaptive TPS optimizes the use of charged particles for tumours with
intermediate hypoxic levels. For 12C-ions, the LET values in the
target region are not high enough to induce a complete re-sensitization
(OER∼1) for totally anoxic cells, and this limitation of light ions
is considered the reason of the limited improved local control in clinical
trials15. Kill-painting provides an optimal redistribution of
the LET components, according to the measured oxygen concentration, potentially
leading to a much higher benefit. The dynamic nature of tumour hypoxia is of
course challenging for an adaptive treatment plan. Our method allows fast
recalculation of an optimized plan according to the changes of the tumour
oxygenation in time. Reoxygenation, which has been indicated as a possible
relevant issue46, can be included in the model, pending
quantitative data from functional imaging. However, hypoxia is a major problem
especially in hypofractionation schemes, where re-oxygenation is limited or
completely missing for single-fraction high-dose treatments. Charged particles
are ideal tools for hypofractionation (5), and indeed most clinical trials at
NIRS use a very limited number of fractions of C-ions, down to single fractions
for non-small cell lung cancers13. The adaptive TPS developed
here is therefore a powerful tool for hypofractionated particle therapy.The major limitations of the present approach, which relies on precise
information on intra-tumour pO distribution, are
related to the accuracy and reproducibility of the functional imaging
techniques. One major problem which is in the course of investigation is the
translation of PET uptake information to oxygen concentration data4748.The present OER model does not explicitly include a dependence on particle type,
even if the TPS implementation supports this feature. Our measurements
demonstrate that for light to intermediate weight ions (C, N, O), the track
structure impact on OER is negligible, while it may be significant for heavier
particles, such as Si (see triangles in Fig. 3).
Kill-painting of hypoxic tumours will be more effective using heavier ions, such
as oxygen33. Oxygen beams reach LET values over
200 keV/μm in the tumour, and having a mass very close
to carbon, the same OER model we introduced here can be safely used. Since the
high LET of oxygen beams may present counter-indications for the normal tissue,
their use could be more advantageous in a mixed beam treatment, in combination
with lower LET ions. In this connection, we recently enhanced our TPS with the
possibility to combine different ions44 in a multi-ion
optimization. Merging OER-driven and multi-ion optimization will extend the
kill-painting approach with more degrees of freedom, providing useful protocols
for specific clinical cases.It is also important to stress that the implemented model for the OER dependence
is semi-empirical, as we mentioned in the previous section, where the
γ exponent of eq. 5 is here a fitting parameter. However
its value (>1) seems to support the hypothesis related to the oxygen in
the track theory that an increase of LET acts more than linearly as an increase
of pO2. For example, in ref. 38, the
local production of O2 in high LET track is obtained by including in
the track structure calculation the double ionization processes. It is found
that the O2 yield due to this LET dependent process is much larger
than the normal levels. A full mechanistic description of this effect is still
missing.Another limitation of the present results is arising from the non-negligible
difference in sensitivity found in chronic hypoxia (the condition most relevant
in clinical cases) as compared to acute hypoxia (the condition verified in the
present experiments). We recently initiated the analysis of the effect of ion
beams in chronic hypoxia49, and once extensive measurements will
be accomplished also for this condition, they could be transferred in the same
way to the present approach. Finally the use of CHO cells is motivated, beside
their simplicity and standardized handling protocols, by their
α/β ratio, similar to a sensitive humantumour tissue.
Moreover in a previous work8, OER measurements for Chinese
hamster cells (V79), were similar to human salivary gland (HSG) cells. However
the validation of the present model with selected data points collected for
human cells will provide an important outlook of the present work, before its
clinical implementation.The present approach exploits the use of charged particles and compared to photon
dose painting presents several advantages. Increasingly important research has
been carried in this field223046, where in principle a
similar compensation of the hypoxia induced radioresistance is performed only by
means of increasing the radiation dose, while having the same limitations in
terms of accuracy of the PET imaging. The latter method, however, appears to be
less convenient for two aspects. Firstly a general increase of dose in the
entrance channel with photons has a larger impact on the normal tissue than a
similar increase in particle therapy, where normally the number of irradiation
ports are much lower. Moreover the lack of LET as an additional relevant
parameter, imposes an absolute larger amount of dose to be boosted in the
hypoxic regions to overcome OER.
Conclusions and outlook
The kill-painting approach is a biologically driven inverse planning technique
with a new optimization quantity. The biological isoffective dose is optimized
in the local tumour microenvironment. This allows exploiting simultaneously the
potential advantages of functional imaging and the flexibility of actively
scanned particle therapy.Kill-painting allows optimization of treatment plans in the presence of any type
of intra-tumour heterogeneity. Heterogeneity is emerging as an important
prognostic factor, and targeting multiple tumour compartments is a possible
solution to fight radioresistance and achieve sustainable responses50. The input in this case should be an intra-tumour map from a
specific functional imaging tool, and a model analogous to the present one for
the corresponding sub-volume radiosensitivity, including its LET dependence.
Examples are stem cells niches14, which could be identified by
imaging their related marker CD133 by 64Cu-ATSM tracer (copper-
diacetyl-methylthiosemicarbazone)51, or even with
near-infrared fluorescence molecular tomography52, and regions of
increased repair activity through γH2AX labeling5354.
Materials and Methods
Cell culture
At GSI, Chinese Hamster Ovary cells (CHO) were obtained from the American tissue
culture collection. At NIRS, CHO cells were provided by the RIKEN BRC. They were
grown in Ham´s F12 medium (SIGMA) supplemented with 10% fetal bovine
serum and antibiotics (100 U/ml penicillin and
100 μg/ml streptomycin all Biochrom AG, Berlin, Germany)
under humidified air with 5% carbon dioxide at
37 oC.For the GSI experiments, cells were seeded in a ring consisting of
polyvinyl-chloride and with an internal diameter of 24 mm and a
width of 3 mm at a concentration of
5 × 104 one day before
the irradiation. Both sides of the sample ring were covered with a gas permeable
foil of 25 μm thickness (BioFolie25, in vitro
Systems and Services, Göttingen, Germany). One layer of foil
corresponds to a water-equivalent thickness of
47 μm.For the NIRS experiments cells were harvested with 0.05% Trypsin-EDTA and seeded
in 3.8 cm-diameter glass dishes at a concentration of
2 × 105 one day before
the irradiation.
Colony forming assay
After irradiation cells were rinsed with PBS. For harvesting, cells were treated
with trypsin, 5 minutes at 37 oC and then
re-suspended in 1 ml of fresh medium. Cell number was calculated
with a Coulter counter analyser (Beckman Coulter). Approximately 100 surviving
cells were re-seeded per 6 cm plastic dishes in 5 ml of
fresh medium. For each irradiated point of each survival curve, 3 different
dishes were prepared.After re-seeding, cells were incubated for 7 days at GSI and 12 days at NIRS,
according to the locally established protocols, enough for the surviving cells
to proliferate over 50 clones/colony.The resulting colonies were fixed with 10% formalin in PBS for 10 minutes, and
stained with 1% methylene blue in water. Colonies consisting of more than 50
cells were counted as survivors.Every survival measurement was repeated in 3 independent experiments (biological
replicates), where for each biological replicate the colonies counting was
performed from 3 separate samples (technical replicates). For every measurement
at given oxygen concentration a simultaneous irradiation in fully oxic
conditions is performed in order to have a contemporary ‘oxic
control’.
Hypoxic chambers
a) GSI chambers
For the irradiation under hypoxic conditions, at GSI special designed and
patented exposure chambers have been used, which allow irradiating of cell
cultures with X-rays or ions under defined oxygenation conditions55.The chamber is cut from a single piece of polyetheretherketone (PEEK). The
top cover is transparent polymethylmethacrylate (PMMA) to allow position
control of the sample. The front wall is used as irradiation window and has
a thickness of 1mm, 1.23 mm water equivalent. A system of hose
couplings allows to gas the chamber and to keep it gas-tight afterwards for
irradiation. Since PEEK and PMMA are known to contain dissolved oxygen, the
possible release of oxygen inside the chambers after irradiation was tested
by measuring the actual concentration with a fiber-optic oxygen meter,
revealing no measurable effect.Two different devices have been used. Single sample irradiation chamber (SHC)
or multiple samples hypoxic chamber (MHC, 3 samples at the same time).
b) NIRS chambers
At NIRS a multi-sample hypoxic chamber was used. The chamber is made of steel
and has 8 different irradiation windows in 2 rows (X-rays hypoxic chamber,
horizontal irradiation56) or 7 in one line (ion hypoxic
chamber57). The Petri dishes used for the ion irradiation
have a small pocket on one side to contain the medium during the irradiation
(see Fig. 5d). For the ion irradiation, samples are in
vertical position. This peculiarity gives the possibility to keep high
humidity atmosphere during irradiation. Cells were not seeded in the area
where the pocket is placed, to avoid beam degradation and different LET in
the same sample.
Monoenergetic Irradiation
Every measurement was performed at a given dose averaged LET, which is defined as
the summation of the LET of all the individual particles composing the beam
weighted for their relative doseswith LETi, D and
F, denoting LET value, dose and fluence, respectively,
of the individual beam component i.
a) NIRS-HIMAC
To obtain the required dose averaged LET, a passive beam has been used at
HIMAC.Carbon ions having a from 30 to
300 keV/μm were provided by a primary energy beam of
290 MeV/nucleon.Silicon ions having a of
400 keV/μm were provided by a primary energy beam of
490 MeV/nucleon.X-ray irradiation was produced by a generator (SHIMADZU, PANTAC HF-320S)
operated at 200 kVp and 20 mA58.
b) GSI-SIS and HIT
To obtain a sufficiently high LET, the chambers were irradiated with an
extended 3D-plan covering 1cm in depth, using a bolus of 30 mm
and 5 ion energies. All the samples were irradiated with an actively scanned
beam.Nitrogen and Carbon ions experiments were performed at SIS in GSI, while the
Oxygen beam experiment was performed at HIT, Heidelberg. Nitrogen ions had a
of 160 keV/μm
and Oxygen ions had a of
140 keV/μm.X-ray irradiation was carried out with a Isovolt DS1 X-ray machine (Seifert,
Ahrensberg, Germany) operated at 250 kVp and 16 mA
with 7 mm beryllium, 1 mm aluminum and
1 mm copper filtering and a dose rate of
2 Gy/min.For the extended target irradiation, used to simulate therapy conditions with a
complex tumour with variable oxygen concentration, a phantom was assembled by
combining tissue culture flasks (TCF) and hypoxic chambers (HC) in order to
increase the number of measurement points along the entrance channel and the
target region. The full length was 18 cm at NIRS and
16 cm at GSI in water equivalent (weq) along the beam directions,
while the target was placed in the middle with a lateral extension of
4 cm × 4 cm and a
depth of 6 cm (weq).In the NIRS irradiation 2 opposite fields passively shaped with a 6cm spread out
Bragg peak (SOBP) were superimposed, rotating the sample by 180 degrees between
the two irradiation shots. The delivered dose in this case was higher than it
was planned, due to a dosimetry problem at the accelerator, but the actual dose
was recalculated with respect to the oxic control data, and then the full plan
was recomputed with this dose (9.5 Gy(RBE)) for the differently
oxygenated regions.At GSI the irradiations were performed in Cave M, with full active scanning
capabilities. The samples were placed on a support tilted by 2.203 degrees in
order to compensate the fixed inclination of the beam pipe and obtain a real 180
degrees irradiation, which emphasize the efficiency of the kill-painting method.
The beam energy spacing was chosen in general for depth steps of
3 mm, while at the boundaries between different sensitivity areas,
the energy slices were selected in order to avoid occurrence of the peak close
to the boundary and consequent fluctuations in the biological effect. A triple
chamber hosting three samples at a given concentration and different depth
positions was used. In order to minimize range uncertainties and to reduce the
overall size of the phantom, the chambers with different concentration were not
piled one after the other, but irradiated on their turn with the same plan, each
one placed at the corresponding depth position in water equivalent (see Fig. 5). This was realized in 3 irradiations for each
configuration, grouped into 2 beam times performed at GSI.
Treatment Planning
a) TRiP98
All treatment plans were done using an extended version of the TRiP98
treatment planning system. TRiP98 (Treatment planning for particles) is the
first treatment planning system dedicated to active scanned carbon ion
therapy. It was in use for all the irradiations of the GSI pilot project.
Nowadays it serves as a research tool in several facilities as well as a
reference for commercial planning systems dedicated to active scanned
particle therapy. Among the main features of TRiP98 is the possibility to
consider the contribution of all the particles composing the mixed
irradiation field.The general structure of the code, including the present implementation, is
available in the SI, while further details are available in refs 33,42, 43, 44,59,60
b) Kill-painting implementation
The main task of the optimization module is the minimization of an objective
function , which is dependent on the particle
numbers within each spot of the raster scanning (components of the vector
) and is including the deviations, at
any voxel i, of the prescribed dose to
the actual at any updating iteration of the
vector .where the second sum is running over the organ-at-risks (OAR) voxels and is
modulated by the Heavyside function Θ, evaluating to 1
when a maximum allowed dose is exceeded, and
otherwise to 0. and are adjustable weights for the two contributions, allowing to
choose between OAR sparing and target dose conformity.is normally a biologically effective
(RBE-weighted) dose generated by the contributions of all the beam
components to a given voxel59where the , are
the ion parameters after dose averaging in the mixed radiation field
resulting on the voxel i, and the are terms
representing the contributions of all the raster spots to the voxel
(60).In order to consider an “isoeffective dose accounting for
hypoxia”, we then modified the values of these parameters at any
voxel, accounting for the local OER value, depending on a local constant
quantity , and another quantity () which is updated in the course of the
optimization,The latter decomposition is possible thanks to the dose modifying nature of
the quantity.Since the algorithms of biological dose optimization are mainly gradient
based, it is necessary also to modify the gradients of the biological effect
with respect to the particle numbers. Thus, similarly, a modification of the
gradients driving the minimization of the objective function is
necessary,assuring that the particle numbers and the LET distribution update is driven
by the OER effect.
Additional Information
How to cite this article: Tinganelli, W. et al. Kill-painting of
hypoxic tumours in charged particle therapy. Sci. Rep. 5, 17016; doi:
10.1038/srep17016 (2015).
Authors: Drosoula Giantsoudi; Clemens Grassberger; David Craft; Andrzej Niemierko; Alexei Trofimov; Harald Paganetti Journal: Int J Radiat Oncol Biol Phys Date: 2013-06-19 Impact factor: 7.038
Authors: Walter Tinganelli; Ning-Yi Ma; Cläre Von Neubeck; Andreas Maier; Corinna Schicker; Wilma Kraft-Weyrather; Marco Durante Journal: J Radiat Res Date: 2013-07 Impact factor: 2.724
Authors: Wilfred Ngwa; Omoruyi Credit Irabor; Jonathan D Schoenfeld; Jürgen Hesser; Sandra Demaria; Silvia C Formenti Journal: Nat Rev Cancer Date: 2018-02-16 Impact factor: 60.716
Authors: Lucas N Burigo; José Ramos-Méndez; Mark Bangert; Reinhard W Schulte; Bruce Faddegon Journal: Phys Med Biol Date: 2019-01-04 Impact factor: 3.609
Authors: Arnold Pompos; Robert L Foote; Albert C Koong; Quynh Thu Le; Radhe Mohan; Harald Paganetti; Hak Choy Journal: Front Oncol Date: 2022-06-14 Impact factor: 5.738