Literature DB >> 26581881

Metabolic Control With the Bio-inspired Artificial Pancreas in Adults With Type 1 Diabetes: A 24-Hour Randomized Controlled Crossover Study.

Monika Reddy1, Pau Herrero2, Mohamed El Sharkawy2, Peter Pesl2, Narvada Jugnee3, Darrell Pavitt3, Ian F Godsland3, George Alberti3, Christofer Toumazou2, Desmond G Johnston3, Pantelis Georgiou2, Nick S Oliver3.   

Abstract

BACKGROUND: The Bio-inspired Artificial Pancreas (BiAP) is a closed-loop insulin delivery system based on a mathematical model of beta-cell physiology and implemented in a microchip within a low-powered handheld device. We aimed to evaluate the safety and efficacy of the BiAP over 24 hours, followed by a substudy assessing the safety of the algorithm without and with partial meal announcement. Changes in lactate and 3-hydroxybutyrate concentrations were investigated for the first time during closed-loop.
METHODS: This is a prospective randomized controlled open-label crossover study. Participants were randomly assigned to attend either a 24-hour closed-loop visit connected to the BiAP system or a 24-hour open-loop visit (standard insulin pump therapy). The primary outcome was percentage time spent in target range (3.9-10 mmol/l) measured by sensor glucose. Secondary outcomes included percentage time in hypoglycemia (<3.9 mmol/l) and hyperglycemia (>10 mmol/l). Participants were invited to attend for an additional visit to assess the BiAP without and with partial meal announcements.
RESULTS: A total of 12 adults with type 1 diabetes completed the study (58% female, mean [SD] age 45 [10] years, BMI 25 [4] kg/m(2), duration of diabetes 22 [12] years and HbA1c 7.4 [0.7]% [58 (8) mmol/mol]). The median (IQR) percentage time in target did not differ between closed-loop and open-loop (71% vs 66.9%, P = .9). Closed-loop reduced time spent in hypoglycemia from 17.9% to 3.0% (P < .01), but increased time was spent in hyperglycemia (10% vs 28.9%, P = .01). The percentage time in target was higher when all meals were announced during closed-loop compared to no or partial meal announcement (65.7% [53.6-80.5] vs 45.5% [38.2-68.3], P = .12).
CONCLUSIONS: The BiAP is safe and achieved equivalent time in target as measured by sensor glucose, with improvement in hypoglycemia, when compared to standard pump therapy.
© 2015 Diabetes Technology Society.

Entities:  

Keywords:  Bio-inspired Artificial Pancreas; closed-loop insulin delivery; diabetes technology; type 1 diabetes

Mesh:

Substances:

Year:  2015        PMID: 26581881      PMCID: PMC4773972          DOI: 10.1177/1932296815616134

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  28 in total

1.  Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial.

Authors:  Ahmad Haidar; Laurent Legault; Virginie Messier; Tina Maria Mitre; Catherine Leroux; Rémi Rabasa-Lhoret
Journal:  Lancet Diabetes Endocrinol       Date:  2014-11-27       Impact factor: 32.069

2.  Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia.

Authors:  Marc Breton; Anne Farret; Daniela Bruttomesso; Stacey Anderson; Lalo Magni; Stephen Patek; Chiara Dalla Man; Jerome Place; Susan Demartini; Simone Del Favero; Chiara Toffanin; Colleen Hughes-Karvetski; Eyal Dassau; Howard Zisser; Francis J Doyle; Giuseppe De Nicolao; Angelo Avogaro; Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2012-06-11       Impact factor: 9.461

3.  Feasibility of automating insulin delivery for the treatment of type 1 diabetes.

Authors:  Garry M Steil; Kerstin Rebrin; Christine Darwin; Farzam Hariri; Mohammed F Saad
Journal:  Diabetes       Date:  2006-12       Impact factor: 9.461

4.  Outpatient glycemic control with a bionic pancreas in type 1 diabetes.

Authors:  Steven J Russell; Firas H El-Khatib; Manasi Sinha; Kendra L Magyar; Katherine McKeon; Laura G Goergen; Courtney Balliro; Mallory A Hillard; David M Nathan; Edward R Damiano
Journal:  N Engl J Med       Date:  2014-06-15       Impact factor: 91.245

5.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

6.  Threshold-based insulin-pump interruption for reduction of hypoglycemia.

Authors:  Richard M Bergenstal; David C Klonoff; Satish K Garg; Bruce W Bode; Melissa Meredith; Robert H Slover; Andrew J Ahmann; John B Welsh; Scott W Lee; Francine R Kaufman
Journal:  N Engl J Med       Date:  2013-06-22       Impact factor: 91.245

7.  Time lag of glucose from intravascular to interstitial compartment in humans.

Authors:  Ananda Basu; Simmi Dube; Michael Slama; Isabel Errazuriz; Jose Carlos Amezcua; Yogish C Kudva; Thomas Peyser; Rickey E Carter; Claudio Cobelli; Rita Basu
Journal:  Diabetes       Date:  2013-09-05       Impact factor: 9.461

8.  Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomised crossover study.

Authors:  Hood Thabit; Alexandra Lubina-Solomon; Marietta Stadler; Lalantha Leelarathna; Emma Walkinshaw; Andrew Pernet; Janet M Allen; Ahmed Iqbal; Pratik Choudhary; Kavita Kumareswaran; Marianna Nodale; Chloe Nisbet; Malgorzata E Wilinska; Katharine D Barnard; David B Dunger; Simon R Heller; Stephanie A Amiel; Mark L Evans; Roman Hovorka
Journal:  Lancet Diabetes Endocrinol       Date:  2014-06-16       Impact factor: 32.069

9.  Clinical evaluation of a personalized artificial pancreas.

Authors:  Eyal Dassau; Howard Zisser; Rebecca A Harvey; Matthew W Percival; Benyamin Grosman; Wendy Bevier; Eran Atlas; Shahar Miller; Revital Nimri; Lois Jovanovic; Francis J Doyle
Journal:  Diabetes Care       Date:  2012-11-27       Impact factor: 19.112

10.  Overnight glucose control with an automated, unified safety system in children and adolescents with type 1 diabetes at diabetes camp.

Authors:  Trang T Ly; Marc D Breton; Patrick Keith-Hynes; Daniel De Salvo; Paula Clinton; Kari Benassi; Benton Mize; Daniel Chernavvsky; Jéróme Place; Darrell M Wilson; Boris P Kovatchev; Bruce A Buckingham
Journal:  Diabetes Care       Date:  2014-05-30       Impact factor: 19.112

View more
  14 in total

1.  Extensive Assessment of Blood Glucose Monitoring During Postprandial Period and Its Impact on Closed-Loop Performance.

Authors:  Lyvia Biagi; Arthur Hirata Bertachi; Ignacio Conget; Carmen Quirós; Marga Giménez; F Javier Ampudia-Blasco; Paolo Rossetti; Jorge Bondia; Josep Vehí
Journal:  J Diabetes Sci Technol       Date:  2017-06-21

2.  Factors Beyond Carbohydrate to Consider When Determining Meantime Insulin Doses: Protein, Fat, Timing, and Technology.

Authors:  Alison B Evert
Journal:  Diabetes Spectr       Date:  2020-05

Review 3.  Multivariable Adaptive Artificial Pancreas System in Type 1 Diabetes.

Authors:  Ali Cinar
Journal:  Curr Diab Rep       Date:  2017-08-15       Impact factor: 4.810

Review 4.  Artificial Pancreas: Current Progress and Future Outlook in the Treatment of Type 1 Diabetes.

Authors:  Rozana Ramli; Monika Reddy; Nick Oliver
Journal:  Drugs       Date:  2019-07       Impact factor: 9.546

5.  The Bio-inspired Artificial Pancreas for Type 1 Diabetes Control in the Home: System Architecture and Preliminary Results.

Authors:  Pau Herrero; Mohamed El-Sharkawy; John Daniels; Narvada Jugnee; Chukwuma N Uduku; Monika Reddy; Nick Oliver; Pantelis Georgiou
Journal:  J Diabetes Sci Technol       Date:  2019-10-14

6.  Analyzing the Potential of Advanced Insulin Dosing Strategies in Patients With Type 2 Diabetes: Results From a Hybrid In Silico Study.

Authors:  Florian Reiterer; Matthias Reiter; Luigi Del Re; Merete Bechmann Christensen; Kirsten Nørgaard
Journal:  J Diabetes Sci Technol       Date:  2018-04-21

7.  Event-Triggered Model Predictive Control for Embedded Artificial Pancreas Systems.

Authors:  Ankush Chakrabarty; Stamatina Zavitsanou; Francis J Doyle; Eyal Dassau
Journal:  IEEE Trans Biomed Eng       Date:  2017-05-23       Impact factor: 4.538

8.  Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses.

Authors:  Ricardo Sánchez-Peña; Patricio Colmegna; Fabricio Garelli; Hernán De Battista; Demián García-Violini; Marcela Moscoso-Vásquez; Nicolás Rosales; Emilia Fushimi; Enrique Campos-Náñez; Marc Breton; Valeria Beruto; Paula Scibona; Cintia Rodriguez; Javier Giunta; Ventura Simonovich; Waldo H Belloso; Daniel Cherñavvsky; Luis Grosembacher
Journal:  J Diabetes Sci Technol       Date:  2018-07-12

9.  Enhancing automatic closed-loop glucose control in type 1 diabetes with an adaptive meal bolus calculator - in silico evaluation under intra-day variability.

Authors:  Pau Herrero; Jorge Bondia; Oloruntoba Adewuyi; Peter Pesl; Mohamed El-Sharkawy; Monika Reddy; Chris Toumazou; Nick Oliver; Pantelis Georgiou
Journal:  Comput Methods Programs Biomed       Date:  2017-06-01       Impact factor: 5.428

10.  Impact of Accelerating Insulin on an Artificial Pancreas System Without Meal Announcement: An In Silico Examination.

Authors:  Patricio Colmegna; Eda Cengiz; Jose Garcia-Tirado; Kristen Kraemer; Marc D Breton
Journal:  J Diabetes Sci Technol       Date:  2020-06-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.