Literature DB >> 26580699

Interventional multispectral photoacoustic imaging with a clinical ultrasound probe for discriminating nerves and tendons: an ex vivo pilot study.

Jean Martial Mari1,2, Wenfeng Xia1, Simeon J West3, Adrien E Desjardins1.   

Abstract

Accurate and efficient identification of nerves is an essential component of peripheral nerve blocks. While ultrasound (US) imaging is increasingly used as a guidance modality, it often provides insufficient contrast for identifying nerves from surrounding tissues such as tendons. Electrical nerve stimulators can be used in conjunction with US imaging for discriminating nerves from surrounding tissues, but they are insufficient to reliably prevent neural punctures, so that alternative methods are highly desirable. In this study, an interventional multispectral photoacoustic (PA) imaging system was used to directly compare the signal amplitudes and spectra acquired from nerves and tendons ex vivo, for the first time. The results indicate that the system can provide significantly higher image contrast for discriminating nerves and tendons than that provided by US imaging. As such, photoacoustic imaging could be valuable as an adjunct to US for guiding peripheral nerve blocks.

Entities:  

Mesh:

Year:  2015        PMID: 26580699      PMCID: PMC5217182          DOI: 10.1117/1.JBO.20.11.110503

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  26 in total

Review 1.  Complications of peripheral nerve blocks.

Authors:  C L Jeng; T M Torrillo; M A Rosenblatt
Journal:  Br J Anaesth       Date:  2010-12       Impact factor: 9.166

2.  Optical stimulation of neural tissue in vivo.

Authors:  Jonathon Wells; Chris Kao; Karthik Mariappan; Jeffrey Albea; E Duco Jansen; Peter Konrad; Anita Mahadevan-Jansen
Journal:  Opt Lett       Date:  2005-03-01       Impact factor: 3.776

3.  Use of a nerve stimulator does not improve the efficacy of ultrasound-guided supraclavicular nerve blocks.

Authors:  Michael L Beach; Brian D Sites; John D Gallagher
Journal:  J Clin Anesth       Date:  2006-12       Impact factor: 9.452

4.  Images of spinal nerves and adjacent structures with optical coherence tomography: preliminary animal studies.

Authors:  David T Raphael; Changhuei Yang; Nancy Tresser; Jigang Wu; Yaoping Zhang; Linda Rever
Journal:  J Pain       Date:  2007-06-22       Impact factor: 5.820

5.  Biophysical mechanisms of transient optical stimulation of peripheral nerve.

Authors:  Jonathon Wells; Chris Kao; Peter Konrad; Tom Milner; Jihoon Kim; Anita Mahadevan-Jansen; E Duco Jansen
Journal:  Biophys J       Date:  2007-05-25       Impact factor: 4.033

Review 6.  Musculoskeletal sonography: important imaging pitfalls.

Authors:  David A Jamadar; Brian L Robertson; Jon A Jacobson; Gandikota Girish; Brian J Sabb; Yebin Jiang; Yoav Morag
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

7.  Intravascular photoacoustic imaging of human coronary atherosclerosis.

Authors:  Krista Jansen; Antonius F W van der Steen; Heleen M M van Beusekom; J Wolter Oosterhuis; Gijs van Soest
Journal:  Opt Lett       Date:  2011-03-01       Impact factor: 3.776

8.  Extraneural versus intraneural stimulation thresholds during ultrasound-guided supraclavicular block.

Authors:  Paul E Bigeleisen; Nizar Moayeri; Gerbrand J Groen
Journal:  Anesthesiology       Date:  2009-06       Impact factor: 7.892

9.  Fluorescent peptides highlight peripheral nerves during surgery in mice.

Authors:  Michael A Whitney; Jessica L Crisp; Linda T Nguyen; Beth Friedman; Larry A Gross; Paul Steinbach; Roger Y Tsien; Quyen T Nguyen
Journal:  Nat Biotechnol       Date:  2011-02-06       Impact factor: 54.908

10.  Estimation of biological chromophores using diffuse optical spectroscopy: benefit of extending the UV-VIS wavelength range to include 1000 to 1600 nm.

Authors:  Rami Nachabé; Benno H W Hendriks; Marjolein van der Voort; Adrien E Desjardins; Henricus J C M Sterenborg
Journal:  Biomed Opt Express       Date:  2010-11-17       Impact factor: 3.732

View more
  18 in total

1.  Empirical assessment of laser safety for photoacoustic-guided liver surgeries.

Authors:  Jiaqi Huang; Alycen Wiacek; Kelley M Kempski; Theron Palmer; Jessica Izzi; Sarah Beck; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-02-03       Impact factor: 3.732

Review 2.  Emerging Intraoperative Imaging Modalities to Improve Surgical Precision.

Authors:  Israt S Alam; Idan Steinberg; Ophir Vermesh; Nynke S van den Berg; Eben L Rosenthal; Gooitzen M van Dam; Vasilis Ntziachristos; Sanjiv S Gambhir; Sophie Hernot; Stephan Rogalla
Journal:  Mol Imaging Biol       Date:  2018-10       Impact factor: 3.488

Review 3.  Photoacoustic-guided surgery from head to toe [Invited].

Authors:  Alycen Wiacek; Muyinatu A Lediju Bell
Journal:  Biomed Opt Express       Date:  2021-03-16       Impact factor: 3.732

Review 4.  Photoacoustic image-guided interventions.

Authors:  Madhumithra S Karthikesh; Xinmai Yang
Journal:  Exp Biol Med (Maywood)       Date:  2019-11-20

5.  Photoacoustic Spatial Coherence Theory and Applications to Coherence-Based Image Contrast and Resolution.

Authors:  Michelle T Graham; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-02       Impact factor: 2.725

6.  Internal-Illumination Photoacoustic Tomography Enhanced by a Graded-Scattering Fiber Diffuser.

Authors:  Mucong Li; Tri Vu; Georgy Sankin; Brenton Winship; Kohldon Boydston; Russell Terry; Pei Zhong; Junjie Yao
Journal:  IEEE Trans Med Imaging       Date:  2020-12-29       Impact factor: 10.048

7.  Ultrasonic Needle Tracking with a Fibre-Optic Ultrasound Transmitter for Guidance of Minimally Invasive Fetal Surgery.

Authors:  Wenfeng Xia; Sacha Noimark; Sebastien Ourselin; Simeon J West; Malcolm C Finlay; Anna L David; Adrien E Desjardins
Journal:  Med Image Comput Comput Assist Interv       Date:  2017-09-04

8.  Three-Dimensional Ultrasonic Needle Tip Tracking with a Fiber-Optic Ultrasound Receiver.

Authors:  Wenfeng Xia; Simeon J West; Malcolm C Finlay; Rosalind Pratt; Sunish Mathews; Jean-Martial Mari; Sebastien Ourselin; Anna L David; Adrien E Desjardins
Journal:  J Vis Exp       Date:  2018-08-21       Impact factor: 1.355

9.  Photoacoustic-based sO2 estimation through excised bovine prostate tissue with interstitial light delivery.

Authors:  Trevor Mitcham; Houra Taghavi; James Long; Cayla Wood; David Fuentes; Wolfgang Stefan; John Ward; Richard Bouchard
Journal:  Photoacoustics       Date:  2017-07-09

10.  From computer-assisted intervention research to clinical impact: The need for a holistic approach.

Authors:  Sébastien Ourselin; Mark Emberton; Tom Vercauteren
Journal:  Med Image Anal       Date:  2016-06-15       Impact factor: 8.545

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.