Literature DB >> 26569449

Synchronized Desorption Electrospray Ionization Mass Spectrometry Imaging.

Troy J Comi1, Seung Woo Ryu1, Richard H Perry1.   

Abstract

Desorption electrospray ionization (DESI) has emerged as a powerful technique for mass spectral analysis and imaging under ambient conditions. Synchronization of DESI (sDESI) with the ion injection period (IT)of low-duty cycle mass spectrometers has been previously shown to improve sensitivity and reduce the amount of sample depleted during the acquisition of each spectrum (viz. MS scan time). In this report, we describe the development and characterization of an sDESI mass spectrometry imaging source (sDESI-MSI). Our results show that synchronization of DESI with the IT of an LTQ Orbitrap-XL mass spectrometer improves spatial resolution by factors of ∼4-6. In addition, under certain experimental conditions, synchronization was essential to acquire distinct MS images of low-intensity endogenous FAs (< 5% relative intensity) in fingermarks at high sampling frequencies (step sizes ≤ 75 μm). The magnitudes of these improvements in performance depend on the properties of the microdroplet spray, sample, and surface. Simulations that model analyte movement during desorption and the "washing effect" replicate the experimental results with the washing parameter having the greatest impact on performance. Thus, synchronization improves spatial resolution and sensitivity by decreasing the percentage of the total MS scan time that analytes are influenced by the "washing effect". Generally, synchronization of DESI with IT improves performance and expands the range of analytes, surfaces, and experimental conditions amenable to DESI-MSI, especially for analytes that are weakly attached to a surface.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26569449     DOI: 10.1021/acs.analchem.5b03010

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Enhanced Desorption Electrospray Ionization Mass Spectrometry via Synchronizing Ion Generation and Ion Injection.

Authors:  Zhuanghao Hou; Xingchuang Xiong; Xiang Fang; Guangming Huang
Journal:  J Am Soc Mass Spectrom       Date:  2018-11-06       Impact factor: 3.109

Review 2.  Applications of Fourier Transform Ion Cyclotron Resonance (FT-ICR) and Orbitrap Based High Resolution Mass Spectrometry in Metabolomics and Lipidomics.

Authors:  Manoj Ghaste; Robert Mistrik; Vladimir Shulaev
Journal:  Int J Mol Sci       Date:  2016-05-25       Impact factor: 5.923

Review 3.  Advances in mass spectrometry-based metabolomics for investigation of metabolites.

Authors:  Jun-Ling Ren; Ai-Hua Zhang; Ling Kong; Xi-Jun Wang
Journal:  RSC Adv       Date:  2018-06-19       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.