50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.

C Zhao1, A C Konstantinidis, Y Zheng, T Anaxagoras, R D Speller, J Kanicki.   

Abstract

Wafer-scale CMOS active pixel sensors (APSs) have been developed recently for x-ray imaging applications. The small pixel pitch and low noise are very promising properties for medical imaging applications such as digital breast tomosynthesis (DBT). In this work, we evaluated experimentally and through modeling the imaging properties of a 50 μm pixel pitch CMOS APS x-ray detector named DynAMITe (Dynamic Range Adjustable for Medical Imaging Technology). A modified cascaded system model was developed for CMOS APS x-ray detectors by taking into account the device nonlinear signal and noise properties. The imaging properties such as modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were extracted from both measurements and the nonlinear cascaded system analysis. The results show that the DynAMITe x-ray detector achieves a high spatial resolution of 10 mm(-1) and a DQE of around 0.5 at spatial frequencies  <1 mm(-1). In addition, the modeling results were used to calculate the image signal-to-noise ratio (SNRi) of microcalcifications at various mean glandular dose (MGD). For an average breast (5 cm thickness, 50% glandular fraction), 165 μm microcalcifications can be distinguished at a MGD of 27% lower than the clinical value (~1.3 mGy). To detect 100 μm microcalcifications, further optimizations of the CMOS APS x-ray detector, image aquisition geometry and image reconstruction techniques should be considered.

Mesh:

Year:  2015        PMID: 26540090     DOI: 10.1088/0031-9155/60/23/8977

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.

Authors:  Qian Cao; Alejandro Sisniega; Michael Brehler; J Webster Stayman; John Yorkston; Jeffrey H Siewerdsen; Wojciech Zbijewski
Journal:  Med Phys       Date:  2017-11-27       Impact factor: 4.071

2.  High-resolution extremity cone-beam CT with a CMOS detector: Task-based optimization of scintillator thickness.

Authors:  Q Cao; M Brehler; A Sisniega; J W Stayman; J Yorkston; J H Siewerdsen; W Zbijewski
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03

3.  Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.

Authors:  Niral M Sheth; Wojciech Zbijewski; Matthew W Jacobson; Godwin Abiola; Gerhard Kleinszig; Sebastian Vogt; Stefan Soellradl; Jens Bialkowski; William S Anderson; Clifford R Weiss; Greg M Osgood; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2018-11-13       Impact factor: 4.071

4.  A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

Authors:  N M Sheth; T De Silva; A Uneri; M Ketcha; R Han; R Vijayan; G M Osgood; J H Siewerdsen
Journal:  Med Phys       Date:  2020-01-06       Impact factor: 4.506

5.  Technical Note: spektr 3.0-A computational tool for x-ray spectrum modeling and analysis.

Authors:  J Punnoose; J Xu; A Sisniega; W Zbijewski; J H Siewerdsen
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.