| Literature DB >> 26539515 |
Nan Zhao1, Ruijie Yang1, Junjie Wang1, Xile Zhang1, Jinna Li1.
Abstract
The study is to investigate a Hybrid IMRT/VMAT technique which combines intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for the treatment of nonsmall cell lung cancer (NSCLC). Two partial arcs VMAT, 5-field IMRT, and hybrid plans were created for 15 patients with NSCLC. The hybrid plans were combination of 2 partial arcs VMAT and 5-field IMRT. The dose distribution of planning target volume (PTV) and organs at risk (OARs) for hybrid technique was compared with IMRT and VMAT. The monitor units (MUs) and treatment delivery time were also evaluated. Hybrid technique significantly improved the target conformity and homogeneity compared with IMRT and VMAT. The mean delivery time of IMRT, VMAT, and hybrid plans was 280 s, 114 s, and 327 s, respectively. The mean MUs needed for IMRT, VMAT, and hybrid plans were 933, 512, and 737, respectively. Hybrid technique reduced V5, V10, V30, and MLD of normal lung compared with VMAT and spared the OARs better with fewer MUs with the cost of a little higher V5, V10, and mean lung dose (MLD) of normal lung compared with IMRT. Hybrid IMRT/VMAT can be a viable radiotherapy technique with better plan quality.Entities:
Mesh:
Year: 2015 PMID: 26539515 PMCID: PMC4619809 DOI: 10.1155/2015/613060
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Treatment planning objectives used for Hybrid IMRT/VMAT, IMRT, and VMAT plans.
| PTV |
| >62.7 Gy |
|
| <72.6 Gy | |
|
| ||
| Normal lung |
| <60% |
|
| <40% | |
|
| <30% | |
|
| <20% | |
| Mean dose | <16 Gy | |
|
| ||
| Spinal cord | Max dose | <50 Gy |
|
| ||
| Esophagus | Max dose | <66 Gy |
| Mean dose | <34 Gy | |
|
| ||
| Heart |
| <80% |
|
| <30% | |
| Mean dose | <30 Gy | |
PTV is planning target volume.
V is percentage volume of OARs receiving at least N Gy of radiation dose.
Figure 1Representative axial, coronal, and sagittal computed tomography slices showing isodose distribution for (a) IMRT, (b) VMAT, and (c) Hybrid IMRT/VMAT. Planning target volume (PTV) shown in red.
Figure 2Representative dose volume histogram for IMRT, VMAT, and Hybrid IMRT/VMAT. The curves of IMRT, VMAT, and Hybrid IMRT/VMAT are indicated in solid lines, dashed lines, and dotted lines, respectively.
The data for PTV coverage for IMRT, VMAT, and Hybrid IMRT/VMAT plans.
| IMRT | VMAT | Hybrid | IMRT versus VMAT | IMRT versus Hybrid | VMAT versus Hybrid | |
|---|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD |
|
|
| |
| PTV | ||||||
|
| 64.6 ± 0.5 | 64.6 ± 0.5 | 65.0 ± 0.3 | >0.05 | <0.05 | <0.05 |
|
| 72.6 ± 1.7 | 73.3 ± 1.7 | 71.5 ± 1.0 | >0.05 | <0.05 | <0.05 |
| CN | 0.79 ± 0.05 | 0.86 ± 0.04 | 0.88 ± 0.03 | <0.05 | <0.05 | <0.05 |
| HI (%) | 11.3 ± 0.7 | 12.6 ± 0.6 | 9.8 ± 0.3 | <0.05 | <0.05 | <0.05 |
PTV is planning target volume, IMRT is intensity modulated radiation therapy, VMAT is volumetric modulated arc therapy, CN is conformation number, and HI is homogeneity index.
The data for OARs sparing for IMRT, VMAT, and Hybrid IMRT/VMAT plans.
| IMRT | VMAT | Hybrid | IMRT versus VMAT | IMRT versus Hybrid | VMAT versus Hybrid | |
|---|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD |
|
|
| |
| Normal lung | ||||||
|
| 67.5 ± 2.7 | 67.9 ± 3.7 | 67.7 ± 3.2 | >0.05 | >0.05 | >0.05 |
|
| 18.7 ± 4.1 | 18.4 ± 4.2 | 17.7 ± 3.9 | >0.05 | <0.05 | <0.05 |
|
| 25.4 ± 4.9 | 25.2 ± 6.1 | 25.5 ± 5.6 | >0.05 | >0.05 | >0.05 |
|
| 35.2 ± 6.9 | 41.7 ± 8.0 | 38.5 ± 7.3 | <0.05 | <0.05 | <0.05 |
|
| 50.0 ± 8.2 | 60.3 ± 11.2 | 57.2 ± 10.7 | <0.05 | <0.05 | <0.05 |
| Mean (Gy) | 14.2 ± 2.2 | 15.2 ± 2.6 | 14.6 ± 2.3 | <0.05 | <0.05 | <0.05 |
| Spinal cord | ||||||
|
| 41.5 ± 10.0 | 35.7 ± 10.5 | 35.9 ± 9.0 | <0.05 | <0.05 | >0.05 |
| Esophagus | ||||||
|
| 67.0 ± 5.7 | 66.2 ± 6.9 | 63.7 ± 7.9 | >0.05 | <0.05 | <0.05 |
| Mean (Gy) | 22.9 ± 9.9 | 23.0 ± 9.6 | 22.4 ± 9.7 | >0.05 | <0.05 | <0.05 |
| Heart | ||||||
|
| 34.0 ± 25.7 | 31.3 ± 24.0 | 31.6 ± 23.8 | >0.05 | <0.05 | >0.05 |
| Mean (Gy) | 8.5 ± 8.8 | 7.4 ± 7.1 | 7.8 ± 7.8 | <0.05 | <0.05 | >0.05 |
|
| 1.1 ± 2.0 | 0.9 ± 1.6 | 0.8 ± 1.5 | <0.05 | <0.05 | >0.05 |
|
| 4.5 ± 5.6 | 2.8 ± 4.0 | 3.2 ± 4.4 | <0.05 | <0.05 | >0.05 |
PTV is planning target volume, IMRT is intensity modulated radiation therapy, VMAT is volumetric modulated arc therapy, CN is conformation number, and HI is homogeneity index.
V is percentage volume of OARs receiving at least N Gy of radiation dose.