Literature DB >> 26538899

Digital model as an alternative to plaster model in assessment of space analysis.

A Anand Kumar1, Abraham Phillip1, Sathesh Kumar1, Anuradha Rawat1, Sakthi Priya1, V Kumaran1.   

Abstract

INTRODUCTION: Digital three-dimensional models are widely used for orthodontic diagnosis. The purpose of this study was to appraise the accuracy of digital models obtained from computer-aided design/computer-aided manufacturing (CAD/CAM) and cone-beam computed tomography (CBCT) for tooth-width measurements and the Bolton analysis.
MATERIALS AND METHODS: Digital models (CAD/CAM, CBCT) and plaster model were made for each of 50 subjects. Tooth-width measurements on the digital models (CAD/CAM, CBCT) were compared with those on the corresponding plaster models. The anterior and overall Bolton ratios were calculated for each participant and for each method. The paired t-test was applied to determine the validity.
RESULTS: Tooth-width measurements, anterior, and overall Bolton ratio of digital models of CAD/CAM and CBCT did not differ significantly from those on the plaster models.
CONCLUSION: Hence, both CBCT and CAD/CAM are trustable and promising technique that can replace plaster models due to its overwhelming advantages.

Entities:  

Keywords:  Bolton's ratio; Computer-aided design/computer-aided manufacturing; cone-beam computed tomography; digital models

Year:  2015        PMID: 26538899      PMCID: PMC4606641          DOI: 10.4103/0975-7406.163506

Source DB:  PubMed          Journal:  J Pharm Bioallied Sci        ISSN: 0975-7406


  15 in total

1.  Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models.

Authors:  Oded Zilberman; Jan A V Huggare; Konstantinos A Parikakis
Journal:  Angle Orthod       Date:  2003-06       Impact factor: 2.079

2.  Comparison of peer assessment rating (PAR) index scores of plaster and computer-based digital models.

Authors:  Matthew Mayers; Allen R Firestone; Robert Rashid; Katherine W L Vig
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-10       Impact factor: 2.650

3.  Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements.

Authors:  Daron R Stevens; Carlos Flores-Mir; Brian Nebbe; Donald W Raboud; Giseon Heo; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-06       Impact factor: 2.650

4.  Three-dimensional imaging of orthodontic models: a pilot study.

Authors:  Jennifer Asquith; Toby Gillgrass; Peter Mossey
Journal:  Eur J Orthod       Date:  2007-10       Impact factor: 3.075

5.  [How precise is the optical Cerec impression?].

Authors:  C Benz; P Schwarz
Journal:  Dtsch Zahnarztl Z       Date:  1991-09

6.  Comparison of space analysis evaluations with digital models and plaster dental casts.

Authors:  Michael F Leifert; Melvyn M Leifert; Stella S Efstratiadis; Thomas J Cangialosi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-07       Impact factor: 2.650

7.  Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography.

Authors:  Niansong Ye; Fan Jian; Junjie Xue; Sheng Wang; Lina Liao; Wenya Huang; Xing Yang; Yang Zhou; Wenli Lai; Jingtao Li; Jing Wang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-12       Impact factor: 2.650

8.  Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions.

Authors:  Matthew G Wiranto; W Petrie Engelbrecht; Heleen E Tutein Nolthenius; W Joerd van der Meer; Yijin Ren
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-01       Impact factor: 2.650

9.  The evolution of the CEREC system.

Authors:  Werner H Mörmann
Journal:  J Am Dent Assoc       Date:  2006-09       Impact factor: 3.634

10.  Development of three-dimensional FE modeling system from the limited cone beam CT images for orthodontic tipping tooth movement.

Authors:  Akira Nakajima; Mamoru Murata; Eiji Tanaka; Yoshinori Arai; Yasumasa Fukase; Yasukazu Nishi; Glenn Sameshima; Noriyoshi Shimizu
Journal:  Dent Mater J       Date:  2007-11       Impact factor: 2.102

View more
  2 in total

Review 1.  Accuracy and reproducibility of dental measurements on tomographic digital models: a systematic review and meta-analysis.

Authors:  Jamille B Ferreira; Ilana O Christovam; David S Alencar; Andréa F J da Motta; Claudia T Mattos; Adriana Cury-Saramago
Journal:  Dentomaxillofac Radiol       Date:  2017-04-26       Impact factor: 2.419

2.  Correlation and agreement of a digital and conventional method to measure arch parameters.

Authors:  Nes Nawi; Alizae Marny Mohamed; Murshida Marizan Nor; Nor Atika Ashar
Journal:  J Orofac Orthop       Date:  2017-11-07       Impact factor: 1.938

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.