Literature DB >> 17974542

Three-dimensional imaging of orthodontic models: a pilot study.

Jennifer Asquith1, Toby Gillgrass, Peter Mossey.   

Abstract

Computer-based digital orthodontic models have been developed that have the potential to replace dental casts. The aim of this study was to examine the accuracy and reproducibility of measurements made on digital models. Ten sets of orthodontic study models were scanned using the Arius3D Foundation System and three-dimensional (3D) images were produced by computer software. Two examiners individually measured 11 parameters on the conventional casts and the digital models on two occasions. The parameters included mesio-distal crown diameter, intercanine and intermolar width, arch length, overjet, and incisor crown height. The measurement techniques were compared using paired t-tests, the coefficient of reliability, and by calculating mean values and the difference between methods. When comparing measurements made on digital models with those on dental casts, systematic errors were detected for five of the 11 parameters at the 10 per cent level. Random errors were a cause of concern for measurements of three parameters. The most accurate and reproducible measurements were lower intercanine width (mean difference between measurements 0.05 +/- 0.32 mm) and overjet (mean difference 0.07 +/- 0.33 mm). Most parameters on the digital models can be reliably measured, and digital models can potentially eliminate the requirement for the production and storage of dental casts, but this will depend on cost.

Mesh:

Year:  2007        PMID: 17974542     DOI: 10.1093/ejo/cjm044

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  19 in total

1.  Orthodontic study cast analysis--reproducibility of recordings and agreement between conventional and 3D virtual measurements.

Authors:  Anders P G Sjögren; Jan E Lindgren; Jan A V Huggare
Journal:  J Digit Imaging       Date:  2009-06-13       Impact factor: 4.056

2.  Multibracket appliance: impression defaults and their reduction by blocking-out  -  a three-dimensional study.

Authors:  Susanne Wriedt; Moritz Foersch; Jan Daniel Muhle; Irene Schmidtmann; Heinrich Wehrbein
Journal:  Clin Oral Investig       Date:  2015-06-24       Impact factor: 3.573

3.  Accuracy of stereolithographically printed digital models compared to plaster models.

Authors:  Leonardo Tavares Camardella; Oswaldo V Vilella; Marleen M van Hezel; Karel H Breuning
Journal:  J Orofac Orthop       Date:  2017-03-30       Impact factor: 1.938

Review 4.  Accuracy and reproducibility of dental measurements on tomographic digital models: a systematic review and meta-analysis.

Authors:  Jamille B Ferreira; Ilana O Christovam; David S Alencar; Andréa F J da Motta; Claudia T Mattos; Adriana Cury-Saramago
Journal:  Dentomaxillofac Radiol       Date:  2017-04-26       Impact factor: 2.419

5.  Correlation and agreement of a digital and conventional method to measure arch parameters.

Authors:  Nes Nawi; Alizae Marny Mohamed; Murshida Marizan Nor; Nor Atika Ashar
Journal:  J Orofac Orthop       Date:  2017-11-07       Impact factor: 1.938

6.  Dimensional accuracy of jaw scans performed on alginate impressions or stone models: A practice-oriented study.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-07       Impact factor: 1.938

7.  Digital model as an alternative to plaster model in assessment of space analysis.

Authors:  A Anand Kumar; Abraham Phillip; Sathesh Kumar; Anuradha Rawat; Sakthi Priya; V Kumaran
Journal:  J Pharm Bioallied Sci       Date:  2015-08

Review 8.  Linear measurements using virtual study models.

Authors:  Nghe S Luu; Liliya G Nikolcheva; Jean-Marc Retrouvey; Carlos Flores-Mir; Tarek El-Bialy; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2012-04-24       Impact factor: 2.079

9.  Technique comparison for efficient orthodontic tooth measurements using digital models.

Authors:  Heather M I Horton; James R Miller; Philippe R Gaillard; Brent E Larson
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

10.  Accuracy and reliability of palatal superimposition of three-dimensional digital models.

Authors:  Dong-Soon Choi; Young-Mok Jeong; Insan Jang; Paul George Jost-Brinkmann; Bong-Kuen Cha
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.