Literature DB >> 23195374

Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography.

Niansong Ye1, Fan Jian, Junjie Xue, Sheng Wang, Lina Liao, Wenya Huang, Xing Yang, Yang Zhou, Wenli Lai, Jingtao Li, Jing Wang.   

Abstract

INTRODUCTION: The aims of this study were to determine the accuracy of volumetric measurements of teeth in vitro by cone-beam computed tomography (CBCT) and to analyze the factors affecting their volume measurements from the CBCT data.
METHODS: We used a sample of CBCT-scanned (voxel sizes: 0.125, 0.20, 0.25, 0.30, and 0.40 mm) and laser-scanned crowns (n = 40) and roots (n = 32). The Tukey test was used to assess the differences between the CBCT-scan and the laser-scan volumes.
RESULTS: There was a statistically significant difference between the laser-scan crown volume and each voxel size of CBCT-scan crown volume (P <0.05). CBCT-scan crown volumes at 0.30 and 0.40 mm were statistically significantly distinct from those at 0.125, 0.20, and 0.25 mm (P <0.05). There was a statistically significant difference between the laser-scan root volume and each voxel size of CBCT-scan root volume (P <0.05). The laser-scan root volume at 0.40 mm was statistically significantly distinct from the volumes at 0.125 and 0.20 mm (P <0.05). The in-vitro volume measurements from the CBCT scans were larger than those of the laser scans: from 21.73% to 43.92% in the crown halves, and from 18.27% to 41.58% in the root halves at the different voxel sizes.
CONCLUSIONS: With increasing voxel sizes during scanning, the volume measurements of teeth tended to be larger. The surface surrounding artifacts might lead to larger volumes.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Mesh:

Year:  2012        PMID: 23195374     DOI: 10.1016/j.ajodo.2012.05.020

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  12 in total

1.  Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT: author response.

Authors:  O Peters; D Maret
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

2.  Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT.

Authors:  N Ye; F Jian; W Lai
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  Digital model as an alternative to plaster model in assessment of space analysis.

Authors:  A Anand Kumar; Abraham Phillip; Sathesh Kumar; Anuradha Rawat; Sakthi Priya; V Kumaran
Journal:  J Pharm Bioallied Sci       Date:  2015-08

4.  Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols.

Authors:  Darren Forst; Simrit Nijjar; Carlos Flores-Mir; Jason Carey; Marc Secanell; Manuel Lagravere
Journal:  Prog Orthod       Date:  2014-12-23       Impact factor: 2.750

5.  Integrated three-dimensional digital assessment of accuracy of anterior tooth movement using clear aligners.

Authors:  Xiao-Juan Zhang; Li He; Hong-Ming Guo; Jie Tian; Yu-Xing Bai; Song Li
Journal:  Korean J Orthod       Date:  2015-11-20       Impact factor: 1.372

6.  Detection of alveolar bone defects with three different voxel sizes of cone-beam computed tomography: an in vitro study.

Authors:  Ting Dong; Lingjun Yuan; Lu Liu; Yifeng Qian; Lunguo Xia; Niansong Ye; Bing Fang
Journal:  Sci Rep       Date:  2019-05-31       Impact factor: 4.379

7.  Accuracy of in vitro mandibular volumetric measurements from CBCT of different voxel sizes with different segmentation threshold settings.

Authors:  Ting Dong; Lunguo Xia; Chenglin Cai; Lingjun Yuan; Niansong Ye; Bing Fang
Journal:  BMC Oral Health       Date:  2019-09-04       Impact factor: 2.757

8.  Accuracy of different tooth surfaces on 3D printed dental models: orthodontic perspective.

Authors:  Ting Dong; Xiaoting Wang; Lunguo Xia; Lingjun Yuan; Niansong Ye; Bing Fang
Journal:  BMC Oral Health       Date:  2020-11-25       Impact factor: 2.757

9.  Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts.

Authors:  Faezeh Yousefi; Abbas Shokri; Foozie Zahedi; Maryam Farhadian
Journal:  Imaging Sci Dent       Date:  2021-10-15

10.  Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography.

Authors:  Wael Nabha; Young-Min Hong; Jin-Hyoung Cho; Hyeon-Shik Hwang
Journal:  Korean J Orthod       Date:  2014-09-25       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.