Literature DB >> 2653036

Accuracy of total bladder volume and residual urine measurements: comparison between real-time ultrasonography and catheterization.

T C Mainprize1, H P Drutz.   

Abstract

The practical value of ultrasonography as a rapid means to accurately determine total bladder volumes and residual urine volume was assessed. Transverse and sagittal bladder diameters were measured with real-time ultrasonography in 50 women: (1) before uroflowmetry, (2) before supine-postvoiding catheterization, (3) before standing catheterization, and (4) after standing catheterization. Calculated bladder volumes, by use of the measured diameters, for each of eight formulas from the literature were compared with their corresponding measured total urine volume, total residual volume, and standing residual volume. The lower limit of ultrasonographic visualization of urine in the bladder was approximately 42 ml. No correlation existed between calculated ultrasound bladder volumes and measured urine volumes for any of the eight formulas. Standing residual volumes were measured in 96% of cases. Ultrasonography cannot as yet rapidly measure bladder volumes accurately. Catheterization remains the best method of assessing postvoid residuals: supine measurements, the gold standard, should be augmented by standing measurements when more accurate volumes are required.

Entities:  

Mesh:

Year:  1989        PMID: 2653036     DOI: 10.1016/0002-9378(89)90327-x

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  7 in total

1.  Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: a comparison with the BladderScan BVI 3000.

Authors:  Jin Ho Choe; Ji Yeon Lee; Kyu-Sung Lee
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-11-07

2.  Determination of postvoid residual by translabial ultrasound.

Authors:  H P Dietz; D Velez; K L Shek; A Martin
Journal:  Int Urogynecol J       Date:  2012-05-10       Impact factor: 2.894

Review 3.  A comprehensive survey on non-invasive wearable bladder volume monitoring systems.

Authors:  Morteza Zakeri Nasrabadi; Hamideh Tabibi; Mahsa Salmani; Mahdieh Torkashvand; Eisa Zarepour
Journal:  Med Biol Eng Comput       Date:  2021-07-14       Impact factor: 2.602

4.  Portable ultrasound determination of urinary residual volume.

Authors:  A E Bent; D E Nahhas; M T McLennan
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  1997

Review 5.  Pelvic ultrasound evaluation for benign prostatic hyperplasia: prediction of obstruction.

Authors:  Daniel B Rukstalis
Journal:  Curr Urol Rep       Date:  2014-05       Impact factor: 3.092

6.  Ultrasonographic evaluation of bladder volume in young children.

Authors:  M Hiraoka; C Hori; S Tsuchida; M Sudo
Journal:  Pediatr Nephrol       Date:  1995-06       Impact factor: 3.714

7.  Improvement in bladder volume reproducibility using A-mode portable ultrasound bladder scanner in moderate-hypofractionated volumetric modulated arc therapy for prostate cancer patients.

Authors:  Shingo Ohira; Riho Komiyama; Naoyuki Kanayama; Kayo Sakai; Takero Hirata; Kento Yoshikata; Yoshihiro Ueda; Masayoshi Miyazaki; Masashi Nakayama; Masahiko Koizumi; Koji Konishi
Journal:  J Appl Clin Med Phys       Date:  2022-02-02       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.