Min Young Lee1, Se Young Ahn1, Hyun Ju Lee1, Jae Yun Jung1, Chung-Ku Rhee1, Myung-Whan Suh2. 1. Department of Otorhinolaryngology-Head & Neck Surgery, Dankook University, College of Medicine, Cheonan, Republic of Korea. 2. Department of Otorhinolaryngology-Head & Neck Surgery, Seoul National University Hospital, Seoul, Republic of Korea. Electronic address: drmung@naver.com.
Abstract
OBJECTIVE: We evaluated conventional ASSR (Bio-logic MASTER II) and NB CE-Chirp ASSR thresholds as objective hearing measures in both normal and hearing loss subjects. METHODS: Patients with sensorineural hearing loss and volunteer normal hearing subjects were enrolled. Pure tone thresholds at 0.5, 1, 2 and 4 kHz were compared with the corresponding thresholds measured using Bio-logic MASTER II and the Eclipse ASSR systems. The threshold differences and correlation with pure tone were measured and reliability was evaluated with Cronbach's α. In part I of the study, all subjects were included, in part II of the study, only mild hearing loss and normal hearing subjects were included. RESULTS: In part I, NB CE-Chirp ASSR revealed a significantly smaller difference in threshold than conventional ASSR, a better correlation and better reliability. However, lower frequencies of NB CE-Chirp tended to be less reliable than higher frequencies. In part II, NB CE-Chirp revealed smaller threshold differences than conventional ASSR. Both correlation scores and reliability values were generally lower in the part II results. CONCLUSION: NB CE-Chirp ASSR generally revealed more favorable outcomes. However, its reliability was reduced at lower frequencies and in patients with milder hearing loss.
OBJECTIVE: We evaluated conventional ASSR (Bio-logic MASTER II) and NB CE-Chirp ASSR thresholds as objective hearing measures in both normal and hearing loss subjects. METHODS:Patients with sensorineural hearing loss and volunteer normal hearing subjects were enrolled. Pure tone thresholds at 0.5, 1, 2 and 4 kHz were compared with the corresponding thresholds measured using Bio-logic MASTER II and the Eclipse ASSR systems. The threshold differences and correlation with pure tone were measured and reliability was evaluated with Cronbach's α. In part I of the study, all subjects were included, in part II of the study, only mild hearing loss and normal hearing subjects were included. RESULTS: In part I, NB CE-Chirp ASSR revealed a significantly smaller difference in threshold than conventional ASSR, a better correlation and better reliability. However, lower frequencies of NB CE-Chirp tended to be less reliable than higher frequencies. In part II, NB CE-Chirp revealed smaller threshold differences than conventional ASSR. Both correlation scores and reliability values were generally lower in the part II results. CONCLUSION: NB CE-Chirp ASSR generally revealed more favorable outcomes. However, its reliability was reduced at lower frequencies and in patients with milder hearing loss.
Authors: Katharina Eder; Daniel Polterauer; Sebastian Semmelbauer; Maria Schuster; Tobias Rader; Eva Hoster; Wilhelm Flatz Journal: Eur Arch Otorhinolaryngol Date: 2021-07-27 Impact factor: 2.503