Blackout and other artefacts in computed tomography caused by fillings in teeth.

P Svendsen, L Quiding, I Landahl.   

Abstract

The disturbing artefacts from fillings in teeth were experimentally studied. Pins of amalgam and composite with different diameters were scanned in 10 mm and 5 mm slices. Amalgam gave five different artefacts: (1) blackout, (2) tuning fork artefact, (3) star-burst, (4) collimation artefact in the narrow slice and (5) connecting line artefact. The composite material with an attenuation of about 5000 HU gave no blackout and mild degree of the other artefacts except for the collimation artefact, which was equal to that with amalgam.

Mesh:

Substances:

Year:  1980        PMID: 7393446     DOI: 10.1007/bf00347800

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  3 in total

1.  Studies on physical phantoms in the EMI scanner.

Authors:  S Aronow
Journal:  J Can Assoc Radiol       Date:  1976-09

2.  New American Dental Association specification no. 27 for direct filling resins. Council on Dental Materials and Devices.

Authors: 
Journal:  J Am Dent Assoc       Date:  1977-06       Impact factor: 3.634

3.  Computed frontal tomography (CFT) of the orbit using the EMI CT 1010 head scanner.

Authors:  L Frisén; L Kjällman; P Svendsen
Journal:  Neuroradiology       Date:  1978-10-02       Impact factor: 2.804

  3 in total
  6 in total

1.  A comparative study of Magnetic Resonance (MR) and Computed Tomography (CT) in the pre-implant evaluation.

Authors:  Valentina Pompa; Sabrina Galasso; Michele Cassetta; Giorgio Pompa; Francesca De Angelis; Stefano Di Carlo
Journal:  Ann Stomatol (Roma)       Date:  2011-02-13

2.  Metal and motion artifacts by cone beam computed tomography (CBCT) in dental and maxillofacial study.

Authors:  Cosimo Nardi; Claudia Borri; Francesco Regini; Linda Calistri; Alessandro Castellani; Chiara Lorini; Stefano Colagrande
Journal:  Radiol Med       Date:  2015-01-30       Impact factor: 3.469

3.  Prior Image Constrained Compressed Sensing Metal Artifact Reduction (PICCS-MAR): 2D and 3D Image Quality Improvement with Hip Prostheses at CT Colonography.

Authors:  Peter Bannas; Yinsheng Li; Utaroh Motosugi; Ke Li; Meghan Lubner; Guang-Hong Chen; Perry J Pickhardt
Journal:  Eur Radiol       Date:  2015-10-31       Impact factor: 5.315

4.  Artefacts of PET/CT images.

Authors:  C Pettinato; C Nanni; M Farsad; P Castellucci; A Sarnelli; S Civollani; R Franchi; S Fanti; M Marengo; C Bergamini
Journal:  Biomed Imaging Interv J       Date:  2006-10-01

5.  Influence of dental metallic artifact from multislice CT in the assessment of simulated mandibular lesions.

Authors:  Andréia Perrella; Patricia M L Lopes; Rodney G Rocha; Marlene Fenyo-Pereira; Marcelo G P Cavalcanti
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

6.  A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model.

Authors:  Tae-Joon Park; Sang-Hyun Lee; Ki-Soo Lee
Journal:  Korean J Orthod       Date:  2012-08-28       Impact factor: 1.372

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.