Literature DB >> 26499998

Femoral rotation in total knee arthroplasty: a comparison of patient individualized jigs with gap balancing in relation to anatomic landmarks.

W Fitz1, S Jäger2, J S Rieger2, E Seebach3, R G Bitsch4.   

Abstract

PURPOSE: The purpose of our study was to compare the accuracy of the rotational position of the femoral component in total knee arthroplasty aligned with patient individualized jigs (PSJ) to a gap balancing technique (GBT).
METHODS: A consecutive series of 21 osteoarthritic patients were treated with 22 cruciate-retaining total knee prostheses. During surgery, the rotation of the femoral component pinholes was recorded for all knees using PSJ and GBT and transferred to computer tomograms (CT). The rotational differences between PSJ and GBT relative to the transepicondylar axis were analysed.
RESULTS: The medium rotation of the femoral component pinholes was 1.3° ± 5.1° (min = -6.3°; max = 14.4°) for PSJ and 0.1 ± 1.4° (min = -1.6°; max = 3.4°) for GBT. Outliers of more than 3° were found more frequently with PSJ in 12 cases but only in one for GBT.
CONCLUSION: Based on our study, we would not recommend relying intra-operatively solely on the CT-based PSJ without the option to adjust or control femoral rotation. LEVEL OF EVIDENCE: II.

Entities:  

Keywords:  Femoral rotation; Gap balancing; Patient-specific jigs; Total knee arthroplasty; Transepicondylar axis

Mesh:

Year:  2015        PMID: 26499998     DOI: 10.1007/s00167-015-3836-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  36 in total

1.  Early revision for component malrotation in total knee arthroplasty.

Authors:  Stephen J Incavo; John J Wild; Kathryn M Coughlin; Bruce D Beynnon
Journal:  Clin Orthop Relat Res       Date:  2007-05       Impact factor: 4.176

2.  How precise can bony landmarks be determined on a CT scan of the knee?

Authors:  J Victor; D Van Doninck; L Labey; B Innocenti; P M Parizel; J Bellemans
Journal:  Knee       Date:  2009-02-05       Impact factor: 2.199

3.  The variability of femoral rotational alignment in total knee arthroplasty.

Authors:  Robert A Siston; Jay J Patel; Stuart B Goodman; Scott L Delp; Nicholas J Giori
Journal:  J Bone Joint Surg Am       Date:  2005-10       Impact factor: 5.284

Review 4.  Rotational alignment of the distal femur: a literature review.

Authors:  J Victor
Journal:  Orthop Traumatol Surg Res       Date:  2009-07-09       Impact factor: 2.256

5.  Does a modified gap-balancing technique result in medial-pivot knee kinematics in cruciate-retaining total knee arthroplasty? A pilot study.

Authors:  Wolfgang Fitz; Sonal Sodha; William Reichmann; Tom Minas
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

6.  Do patient-specific guides improve coronal alignment in total knee arthroplasty?

Authors:  Ryan M Nunley; Bradley S Ellison; Jinjun Zhu; Erin L Ruh; Stephen M Howell; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2011-12-20       Impact factor: 4.176

7.  The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens.

Authors:  Y S Anouchi; L A Whiteside; A D Kaiser; M T Milliano
Journal:  Clin Orthop Relat Res       Date:  1993-02       Impact factor: 4.176

8.  The correction of knee alignment in 225 consecutive total condylar knee replacements.

Authors:  R W Hood; M Vanni; J N Insall
Journal:  Clin Orthop Relat Res       Date:  1981-10       Impact factor: 4.176

9.  Rotational alignment of the distal femur: anthropometric measurements with CT-based patient-specific instruments planning show high variability of the posterior condylar angle.

Authors:  Emmanuel Thienpont; Pierre-Emmanuel Schwab; Frederic Paternostre; Peter Koch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-03       Impact factor: 4.342

10.  The medial trivector approach in total knee arthroplasty.

Authors:  D A Fisher; S M Trimble; K Breedlove
Journal:  Orthopedics       Date:  1998-01       Impact factor: 1.390

View more
  4 in total

1.  Improving radiographic patello-femoral tracking in total knee arthroplasty with the use of a flexion spacer: a case-control study.

Authors:  Davide Giuseppe D'Elicio; Marco Attanasio; Gaetano Ruffo; Stefan Mogos; Nicola Ursino; Riccardo D'Ambrosi; Franco Parente
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-11       Impact factor: 4.342

Review 2.  [Total knee arthroplasty. Patient-specific instruments and implants].

Authors:  Andre F Steinert; Boris M Holzapfel; Lukas Sefrin; Jörg Arnholdt; Maik Hoberg; Maximilian Rudert
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

3.  Kinematic femoral alignment with gap balancing and patient-specific instrumentation in total knee arthroplasty: a randomized clinical trial.

Authors:  Hagen Hommel; Matthew P Abdel; Carsten Perka
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-06

Review 4.  Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty.

Authors:  Henricus J T A M Huijbregts; Riaz J K Khan; Emma Sorensen; Daniel P Fick; Samantha Haebich
Journal:  Acta Orthop       Date:  2016-06-01       Impact factor: 3.717

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.