| Literature DB >> 26499875 |
Miao He1, Wenyong Huang2, Xingwu Zhong3,4.
Abstract
BACKGROUND: The aim of this study was to evaluate central corneal sensitivity after small incision lenticule extraction (SMILE) versus femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for myopia.Entities:
Mesh:
Year: 2015 PMID: 26499875 PMCID: PMC4619500 DOI: 10.1186/s12886-015-0129-5
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Flow diagram of the study selection
Characteristics of prospective comparative studies included in the meta-analysis
| First author | Year | Location | Design | Follow-up | Intervention | No. of eyes | Mean age(y) | Preoperative central corneal sensitivity | Preoperative SE(D) |
|---|---|---|---|---|---|---|---|---|---|
| Li(a) | 2014 | China | Non-randomized | 6 m | FS-LASIK | 33 | 27.33 ± 6.58 | 57.27 ± 6.26 | NA |
| SMILE | 38 | 28.21 ± 7.04 | 58.16 ± 3.37 | NA | |||||
| Wei | 2013 | China | Non-randomized | 3 m | FS-LASIK | 54 | 25.44 ± 7.15 | 58.1 ± 4.3 | NA |
| SMILE | 61 | 27.44 ± 6.52 | 56.6 ± 4.5 | NA | |||||
| Demirok | 2013 | Turkey | Randomized | 6 m | FS-LASIK | 28 | 26.2 ± 4.4 | 56.2 ± 5.0 | 4.00 ± 1.40 |
| SMILE | 28 | 26.2 ± 4.4 | 56.8 ± 4.7 | 3.90 ± 1.50 | |||||
| Gao | 2014 | China | Non-randomized | 3 m | FS-LASIK | 32 | 22.75 ± 4.28 | 57.66 ± 3.25 | NA |
| SMILE | 15 | 24.53 ± 4.05 | 58.48 ± 2.84 | NA | |||||
| Li(b) | 2013 | China | Non-randomized | 6 m | FS-LASIK | 42 | 28.3 ± 5.5 | 58.06 ± 3.8 | 8.46 ± 2.15 |
| SMILE | 32 | 27.1 ± 4.0 | 58.26 ± 4.5 | 6.56 ± 1.28 |
The results were performed as Mean ± SD
FS-LASIK femtosecond laser-assisted laser in situ keratomileusis, SMILE small incision lenticule extraction, y year, SE spherical equivalent, D diopter, m month, NA not available
Evaluation of the quality of the included studies in this meta-analysis using Quality Index
| First author | Year | Quality score component | Score | ||||
|---|---|---|---|---|---|---|---|
| I | II | III | IV | V | Over all | ||
| Li(a) | 2014 | 10 | 3 | 4 | 3 | 5 | 25 |
| Wei | 2013 | 9 | 3 | 4 | 2 | 5 | 23 |
| Demirok | 2013 | 9 | 3 | 4 | 4 | 5 | 25 |
| Gao | 2014 | 9 | 3 | 4 | 2 | 5 | 23 |
| Li(b) | 2013 | 10 | 3 | 4 | 3 | 5 | 25 |
I: Reporting; II: External Validity; III: Bias; IV: Confounding; V: Power
The results of the meta-analysis for central corneal sensitivity after FS-LASIK and SMILE
| Time points | WMD (95 % CI) | Test for heterogeneity | Test for overall effect | |||||
|---|---|---|---|---|---|---|---|---|
| Estimate | Lower | Up |
| I2 |
| Z |
| |
| Pre-operation | 0.00 | −0.23 | 0.23 | 4.78 | 16.30 % | 0.310 | 0.00 | 0.998 |
| One week after surgery | −17.35 | −26.54 | −8.16 | 59.08 | 93.20 % | <0.001 | 3.70 | <0.001 |
| One month after surgery | −17.52 | −25.10 | −9.94 | 41.67 | 90.40 % | <0.001 | 4.53 | <0.001 |
| Three months after surgery | −14.64 | −20.08 | −9.21 | 23.35 | 82.90 % | <0.001 | 5.28 | <0.001 |
| Six months after surgery | −2.02 | −4.23 | 0.19 | 12.72 | 68.60 % | 0.013 | 1.79 | 0.074 |
FS-LASIK femtosecond laser-assisted laser in situ keratomileusis, SMILE small incision lenticule extraction, WMD Weighted mean differences which were computed by using a random effects model
Results of leave-one-out analysis in central corneal sensitivity after FS-LASIK and SMILE
| Study excluded | WMD (95 %) | Test for heterogeneity | Test for overall effect | |||||
|---|---|---|---|---|---|---|---|---|
| Estimate | Lower | Up |
| I2 |
| Z |
| |
| One week after surgery | ||||||||
| Li(a) | −19.56 | −29.72 | −9.40 | 48.21 | 93.80 % | <0.001 | 3.77 | <0.001 |
| Wei | −14.85 | −25.08 | −4.63 | 37.04 | 91.90 % | <0.001 | 2.85 | <0.001 |
| Demirok | −17.97 | −29.26 | −6.69 | 56.87 | 94.70 % | <0.001 | 3.12 | 0.002 |
| Gao | −14.47 | −24.74 | −4.20 | 44.12 | 93.20 % | <0.001 | 2.76 | 0.006 |
| Li(b) | −19.90 | −28.96 | −10.84 | 32.36 | 90.70 % | <0.001 | 4.13 | <0.001 |
| One month after surgery | ||||||||
| Li(a) | −19.85 | −27.61 | −12.09 | 28.97 | 89.60 % | <0.001 | 5.01 | <0.001 |
| Wei | −15.24 | −23.63 | −6.86 | 28.78 | 89.60 % | <0.001 | 3.56 | <0.001 |
| Demirok | −18.49 | −27.62 | −9.36 | 37.52 | 92.00 % | <0.001 | 3.97 | <0.001 |
| Gao | −15.15 | −23.34 | −6.96 | 27.49 | 89.10 % | <0.001 | 3.63 | <0.001 |
| Li(b) | −18.81 | −27.702 | −9.91 | 33.19 | 91.90 % | <0.001 | 4.14 | <0.001 |
| Three months after surgery | ||||||||
| Li(a) | −15.77 | −21.61 | −9.94 | 18.34 | 83.60 % | <0.001 | 5.30 | <0.001 |
| Wei | −12.80 | −19.34 | −6.25 | 16.45 | 81.80 % | 0.001 | 3.83 | <0.001 |
| Demirok | −15.45 | −21.60 | −9.30 | 18.89 | 84.10 % | <0.001 | 4.92 | <0.001 |
| Gao | −12.85 | −19.65 | −6.06 | 18.34 | 83.60 % | <0.001 | 3.71 | <0.001 |
| Li(b) | −16.16 | −21.61 | −10.71 | 15.45 | 80.60 % | 0.001 | 5.81 | <0.001 |
| Six months after surgery | ||||||||
| Li(a) | −14.64 | −20.08 | −9.21 | 23.35 | 82.90 % | <0.001 | 5.28 | <0.001 |
| Wei | −2.75 | −6.20 | 0.69 | 12.34 | 75.70 % | 0.006 | 1.57 | 0.117 |
| Demirok | −2.45 | −5.40 | 0.51 | 12.56 | 76.10 % | 0.006 | 1.62 | 0.105 |
| Gao | −2.93 | −5.29 | −0.58 | 6.26 | 52.10 % | 0.100 | 2.44 | 0.015 |
| Li(b) | −1.29 | −3.29 | 0.72 | 8.26 | 63.70 % | 0.041 | 1.26 | 0.208 |
WMD Weighted mean differences which were computed by using a random effects model, FS-LASIK femtosecond laser-assisted laser in situ keratomileusis, SMILE small incision lenticule extraction