Literature DB >> 2649648

Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses.

F W Sunderman1, S M Hopfer, T Swift, W N Rezuke, L Ziebka, P Highman, B Edwards, M Folcik, H R Gossling.   

Abstract

Co, Cr, and Ni concentrations were determined by electrothermal atomic absorption spectrophotometry in serum and urine specimens collected from a group of 28 patients at intervals of from 1 day to 2.5 years after total knee or hip arthroplasty with porous-coated prostheses fabricated of Co-Cr alloy (ASTM F-75-82). Two control groups were also tested: (a) 42 healthy adults and (b) 16 orthopaedic patients after total knee or hip arthroplasty with porous-coated prostheses fabricated predominantly of Ti-Al-V alloy (ASTM F-136-84). All prostheses contained polyethylene components to avoid metal-to-metal contact. Mean Co concentrations in serum and urine were slightly increased in patients with Co-Cr knee implants at 6-120 weeks after surgery, compared with (a) preoperative values, (b) corresponding values in patients with Co-Cr hip implants, and (c) corresponding values in control patients with Ti-Al-V knee and hip prostheses. Substantially increased Co levels were observed in serum and urine of two patients at 7 weeks and 22 months postarthroplasty, associated with loosening of the prostheses; one of the patients also had elevated Cr levels in serum and urine. Although ASTM F-75-82 and F-136-84 alloys contain very little Ni (less than 1.0 and less than 0.2% Ni, respectively, by wt), mean Ni concentrations in serum and urine were greatly increased at 1-2 days after implantation of Ti-Al-V and Co-Cr prostheses, diminishing by 2 weeks. The postoperative hypernickelemia and nickeluresis may reflect contamination of the operative field with Ni-containing particles from the drills, cutting jigs, and drilling jigs, or it may represent a previously unrecognized pathophysiological response to surgery.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2649648     DOI: 10.1002/jor.1100070302

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  22 in total

1.  The imaging appearances of metallosis.

Authors:  E J Heffernan; F O Alkubaidan; T O Nielsen; P L Munk
Journal:  Skeletal Radiol       Date:  2007-09-18       Impact factor: 2.199

2.  Metallic ion release after knee prosthesis implantation: a prospective study.

Authors:  Adrien Lons; Sophie Putman; Gilles Pasquier; Henri Migaud; Elodie Drumez; Julien Girard
Journal:  Int Orthop       Date:  2017-06-14       Impact factor: 3.075

3.  A short-term cross-over study on oral administration of soluble and insoluble cobalt compounds: sex differences in biological levels.

Authors:  J M Christensen; O M Poulsen; M Thomsen
Journal:  Int Arch Occup Environ Health       Date:  1993       Impact factor: 3.015

4.  Mechanically assisted taper corrosion in modular TKA.

Authors:  Christina M Arnholt; Daniel W MacDonald; Mariya Tohfafarosh; Jeremy L Gilbert; Clare M Rimnac; Steven M Kurtz; Gregg Klein; Michael A Mont; Javad Parvizi; Harold E Cates; Gwo-Chin Lee; Arthur Malkani; Mattheuw Kraay
Journal:  J Arthroplasty       Date:  2014-05-28       Impact factor: 4.757

Review 5.  [Metal implant sensitivity: clinical and histological presentation].

Authors:  D Hartmann; V Letulé; J J Schneider; M J Flaig
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

6.  The cytotoxicity of chromium in osteoblasts: effects on macromolecular synthesis.

Authors:  J Ning; C Henderson; M H Grant
Journal:  J Mater Sci Mater Med       Date:  2002-01       Impact factor: 3.896

7.  Serum and urine metal levels in patients with metal-on-metal surface arthroplasty.

Authors:  Anastasia K Skipor; Patricia A Campbell; Leslie M Patterson; Harlan C Anstutz; Thomas P Schmalzried; Joshua J Jacobs
Journal:  J Mater Sci Mater Med       Date:  2002-12       Impact factor: 3.896

8.  Cytotoxic and apoptotic effects of cobalt and chromium ions on J774 macrophages - Implication of caspase-3 in the apoptotic pathway.

Authors:  I Catelas; A Petit; D J Zukor; O L Huk
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

9.  The interaction of the orthopaedic metals, chromium VI and nickel, with hepatocytes.

Authors:  M Gunaratnam; M H Grant
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

10.  [Metal sensitivity in patients with joint replacement arthroplasties before and after surgery].

Authors:  C Rau; P Thomas; M Thomsen
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

View more