Literature DB >> 26479724

Realistic analytical polyhedral MRI phantoms.

Tri M Ngo1, George S K Fung2, Shuo Han1, Min Chen3,4, Jerry L Prince1,5, Benjamin M W Tsui2, Elliot R McVeigh1, Daniel A Herzka1.   

Abstract

PURPOSE: Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedical shapes.
METHODS: The Fourier transform of a polyhedron was implemented and its accuracy in representing faceted and smooth surfaces was characterized. Realistic anthropomorphic polyhedral brain and torso phantoms were constructed and their use in simulated 3D and two-dimensional (2D) MRI acquisitions was described.
RESULTS: Using polyhedra, the Fourier transform of faceted shapes can be computed to within machine precision. Smooth surfaces can be approximated with increasing accuracy by increasing the number of facets in the polyhedron; the additional accumulated numerical imprecision of the Fourier transform of polyhedra with many faces remained small. Simulations of 3D and 2D brain and 2D torso cine acquisitions produced realistic reconstructions free of high frequency edge aliasing compared with equivalent voxelized/rasterized phantoms.
CONCLUSION: Analytical polyhedral phantoms are easy to construct and can accurately simulate shapes of biomedical interest. Magn Reson Med 76:663-678, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  Fourier transform; analytical phantom; magnetic resonance imaging; simulation

Mesh:

Year:  2015        PMID: 26479724      PMCID: PMC4837112          DOI: 10.1002/mrm.25888

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  MRI simulator with object-specific field map calculations.

Authors:  Duane A Yoder; Yansong Zhao; Cynthia B Paschal; J Michael Fitzpatrick
Journal:  Magn Reson Imaging       Date:  2004-04       Impact factor: 2.546

3.  Realistic simulation of cardiac magnetic resonance studies modeling anatomical variability, trabeculae, and papillary muscles.

Authors:  C Tobon-Gomez; F M Sukno; B H Bijnens; M Huguet; A F Frangi
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

4.  CRUISE: cortical reconstruction using implicit surface evolution.

Authors:  Xiao Han; Dzung L Pham; Duygu Tosun; Maryam E Rettmann; Chenyang Xu; Jerry L Prince
Journal:  Neuroimage       Date:  2004-11       Impact factor: 6.556

5.  Three-dimensional analytical magnetic resonance imaging phantom in the Fourier domain.

Authors:  Cheng Guan Koay; Joelle E Sarlls; Evren Ozarslan
Journal:  Magn Reson Med       Date:  2007-08       Impact factor: 4.668

6.  Topology-preserving tissue classification of magnetic resonance brain images.

Authors:  Pierre-Louis Bazin; Dzung L Pham
Journal:  IEEE Trans Med Imaging       Date:  2007-04       Impact factor: 10.048

7.  MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology.

Authors:  W Paul Segars; Benjamin M W Tsui
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2009-12       Impact factor: 10.961

8.  Computerized tomography and nuclear magnetic resonance.

Authors:  L A Shepp
Journal:  J Comput Assist Tomogr       Date:  1980-02       Impact factor: 1.826

9.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

10.  MRXCAT: Realistic numerical phantoms for cardiovascular magnetic resonance.

Authors:  Lukas Wissmann; Claudio Santelli; William P Segars; Sebastian Kozerke
Journal:  J Cardiovasc Magn Reson       Date:  2014-08-20       Impact factor: 5.364

View more
  3 in total

1.  Test-retest repeatability of human speech biomarkers from static and real-time dynamic magnetic resonance imaging.

Authors:  Johannes Töger; Tanner Sorensen; Krishna Somandepalli; Asterios Toutios; Sajan Goud Lingala; Shrikanth Narayanan; Krishna Nayak
Journal:  J Acoust Soc Am       Date:  2017-05       Impact factor: 1.840

Review 2.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11

3.  Improving the Quantification of the Lateral Geniculate Nucleus in Magnetic Resonance Imaging Using a Novel 3D-Edge Enhancement Technique.

Authors:  Mikhail Lipin; Jean Bennett; Gui-Shuang Ying; Yinxi Yu; Manzar Ashtari
Journal:  Front Comput Neurosci       Date:  2021-12-03       Impact factor: 2.380

  3 in total