Literature DB >> 26473536

CT of the Abdomen with Reduced Tube Voltage in Adults: A Practical Approach.

Adeel R Seyal1, Atilla Arslanoglu1, Samir F Abboud1, Azize Sahin1, Jeanne M Horowitz1, Vahid Yaghmai1.   

Abstract

Recent innovations in computed tomographic (CT) hardware and software have allowed implementation of low tube voltage imaging into everyday CT scanning protocols in adults. CT at a low tube voltage setting has many benefits, including (a) radiation dose reduction, which is crucial in young patients and those with chronic medical conditions undergoing serial CT examinations for disease management; and (b) higher contrast enhancement. For the latter, increased attenuation of iodinated contrast material improves the evaluation of hypervascular lesions, vascular structures, intestinal mucosa in patients with bowel disease, and CT urographic images. Additionally, the higher contrast enhancement may provide diagnostic images in patients with renal dysfunction receiving a reduced contrast material load and in patients with suboptimal peripheral intravenous access who require a lower contrast material injection rate. One limitation is that noisier images affect image quality at a low tube voltage setting. The development of denoising algorithms such as iterative reconstruction has made it possible to perform CT at a low tube voltage setting without compromising diagnostic confidence. Other potential pitfalls of low tube voltage CT include (a) photon starvation artifact in larger patients, (b) accentuation of streak artifacts, and (c) alteration of the CT attenuation value, which may affect evaluation of lesions on the basis of conventional enhancement thresholds. CT of the abdomen with a low tube voltage setting is an excellent radiation reduction technique when properly applied to imaging of select patients in the appropriate clinical setting. (©)RSNA, 2015.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26473536     DOI: 10.1148/rg.2015150048

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  18 in total

1.  New method for the assessment of perineural invasion from perihilar cholangiocarcinoma.

Authors:  Hiroshi Tanaka; Tsuyoshi Igami; Yoshie Shimoyama; Tomoki Ebata; Yukihiro Yokoyama; Kensaku Mori; Masato Nagino
Journal:  Surg Today       Date:  2020-07-04       Impact factor: 2.549

2.  Guideline on the use of iodinated contrast media in patients with kidney disease 2018.

Authors:  Yoshitaka Isaka; Hiromitsu Hayashi; Kazutaka Aonuma; Masaru Horio; Yoshio Terada; Kent Doi; Yoshihide Fujigaki; Hideo Yasuda; Taichi Sato; Tomoyuki Fujikura; Ryohei Kuwatsuru; Hiroshi Toei; Ryusuke Murakami; Yoshihiko Saito; Atsushi Hirayama; Toyoaki Murohara; Akira Sato; Hideki Ishii; Tadateru Takayama; Makoto Watanabe; Kazuo Awai; Seitaro Oda; Takamichi Murakami; Yukinobu Yagyu; Nobuhiko Joki; Yasuhiro Komatsu; Takamasa Miyauchi; Yugo Ito; Ryo Miyazawa; Yoshihiko Kanno; Tomonari Ogawa; Hiroki Hayashi; Eri Koshi; Tomoki Kosugi; Yoshinari Yasuda
Journal:  Clin Exp Nephrol       Date:  2020-01       Impact factor: 2.801

3.  Contrast enhancement in abdominal computed tomography: influence of photon energy of different scanners.

Authors:  Narumi Taguchi; Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Yoshinori Funama; Masanori Imuta; Hideaki Yuki; Yasunori Nagayama; Masafumi Kidoh; Kenichiro Hirata; Yuji Iyama; Tomohiro Namimoto; Noriyuki Kai; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2017-11-06       Impact factor: 3.039

4.  Automatic spectral imaging protocol and iterative reconstruction for radiation dose reduction in typical hepatic hemangioma computed tomography with reduced iodine load: a preliminary study.

Authors:  Wei Li; Aiyin Li; Bin Wang; Xiuyuan Niu; Xin Cao; Xinyi Wang; Hao Shi
Journal:  Br J Radiol       Date:  2018-05-17       Impact factor: 3.039

5.  Guideline on the use of iodinated contrast media in patients with kidney disease 2018.

Authors:  Yoshitaka Isaka; Hiromitsu Hayashi; Kazutaka Aonuma; Masaru Horio; Yoshio Terada; Kent Doi; Yoshihide Fujigaki; Hideo Yasuda; Taichi Sato; Tomoyuki Fujikura; Ryohei Kuwatsuru; Hiroshi Toei; Ryusuke Murakami; Yoshihiko Saito; Atsushi Hirayama; Toyoaki Murohara; Akira Sato; Hideki Ishii; Tadateru Takayama; Makoto Watanabe; Kazuo Awai; Seitaro Oda; Takamichi Murakami; Yukinobu Yagyu; Nobuhiko Joki; Yasuhiro Komatsu; Takamasa Miyauchi; Yugo Ito; Ryo Miyazawa; Yoshihiko Kanno; Tomonari Ogawa; Hiroki Hayashi; Eri Koshi; Tomoki Kosugi; Yoshinari Yasuda
Journal:  Jpn J Radiol       Date:  2020-01       Impact factor: 2.374

6.  Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.

Authors:  Fiachra Moloney; Karl James; Maria Twomey; David Ryan; Tyler M Grey; Amber Downes; Richard G Kavanagh; Niamh Moore; Mary Jane Murphy; Jackie Bye; Brian W Carey; Sean E McSweeney; Conor Deasy; Emmett Andrews; Fergus Shanahan; Michael M Maher; Owen J O'Connor
Journal:  Emerg Radiol       Date:  2018-11-17

7.  Impact of low-kVp scan technique on oral contrast density at abdominopelvic CT.

Authors:  Douglas H Sheafor; Mark D Kovacs; Philip Burchett; Melissa M Picard; Brenton Davis; Andrew D Hardie
Journal:  Radiol Med       Date:  2018-08-06       Impact factor: 3.469

8.  Unenhanced computed tomography for non-invasive diagnosis of hepatic steatosis with low tube potential protocol.

Authors:  Dong Kyun Kim; Joon-Il Choi; Yunjung Choi; Seo Yeon Youn; Hokun Kim
Journal:  Quant Imaging Med Surg       Date:  2022-02

9.  Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography.

Authors:  Tianle Zhang; Xue Geng; Dongxue Li; Yize Xu; Yongxia Zhao
Journal:  Dentomaxillofac Radiol       Date:  2021-01-06       Impact factor: 3.525

Review 10.  Computed Tomography Techniques, Protocols, Advancements, and Future Directions in Liver Diseases.

Authors:  Naveen M Kulkarni; Alice Fung; Avinash R Kambadakone; Benjamin M Yeh
Journal:  Magn Reson Imaging Clin N Am       Date:  2021-08       Impact factor: 1.376

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.