Literature DB >> 26457072

A novel acoustically quiet coil for neonatal MRI system.

Christopher M Ireland1, Randy O Giaquinto2, Wolfgang Loew2, Jean A Tkach2, Ronald G Pratt2, Beth M Kline-Fath3, Stephanie L Merhar4, Charles L Dumoulin2.   

Abstract

MRI acoustic exposure has the potential to elicit physiological distress and impact development in preterm and term infants. To mitigate this risk, a novel acoustically quiet coil was developed to reduce the sound pressure level experienced by neonates during MR procedures. The new coil has a conventional high-pass birdcage RF design, but is built on a framework of sound abating material. We evaluated the acoustic and MR imaging performance of the quiet coil and a conventional body coil on two small footprint NICU MRI systems. Sound pressure level and frequency response measurements were made for six standard clinical MR imaging protocols. The average sound pressure level, reported for all six imaging pulse sequences, was 82.2 dBA for the acoustically quiet coil, and 91.1 dBA for the conventional body coil. The sound pressure level values measured for the acoustically quiet coil were consistently lower, 9 dBA (range 6-10 dBA) quieter on average. The acoustic frequency response of the two coils showed a similar harmonic profile for all imaging sequences. However, the amplitude was lower for the quiet coil, by as much as 20 dBA.

Entities:  

Keywords:  Acoustic noise; Magnetic resonance imaging (MRI); Neonates

Year:  2015        PMID: 26457072      PMCID: PMC4594852          DOI: 10.1002/cmr.b.21287

Source DB:  PubMed          Journal:  Concepts Magn Reson Part B Magn Reson Eng        ISSN: 1552-5031            Impact factor:   1.176


  9 in total

Review 1.  Acoustic noise and functional magnetic resonance imaging: current strategies and future prospects.

Authors:  Edson Amaro; Steve C R Williams; Sukhi S Shergill; Cynthia H Y Fu; Mairead MacSweeney; Marco M Picchioni; Michael J Brammer; Philip K McGuire
Journal:  J Magn Reson Imaging       Date:  2002-11       Impact factor: 4.813

Review 2.  Early neurosensory visual development of the fetus and newborn.

Authors:  Stanley N Graven
Journal:  Clin Perinatol       Date:  2004-06       Impact factor: 3.430

3.  Preliminary report: changes in vital signs of term newborns during MR.

Authors:  M K Philbin; K H Taber; L A Hayman
Journal:  AJNR Am J Neuroradiol       Date:  1996 Jun-Jul       Impact factor: 3.825

4.  An MRI system for imaging neonates in the NICU: initial feasibility study.

Authors:  Jean A Tkach; Noah H Hillman; Alan H Jobe; Wolfgang Loew; Ron G Pratt; Barret R Daniels; Suhas G Kallapur; Beth M Kline-Fath; Stephanie L Merhar; Randy O Giaquinto; Patrick M Winter; Yu Li; Machiko Ikegami; Jeffrey A Whitsett; Charles L Dumoulin
Journal:  Pediatr Radiol       Date:  2012-06-27

5.  Cardiovascular MRI without sedation or general anesthesia using a feed-and-sleep technique in neonates and infants.

Authors:  Jonathan Windram; Lars Grosse-Wortmann; Masoud Shariat; Mary-Louise Greer; Mark W Crawford; Shi-Joon Yoo
Journal:  Pediatr Radiol       Date:  2011-08-23

6.  Transport, monitoring, and successful brain MR imaging in unsedated neonates.

Authors:  Amit M Mathur; Jeffrey J Neil; Robert C McKinstry; Terrie E Inder
Journal:  Pediatr Radiol       Date:  2007-12-19

7.  The acoustic hood: a patient-independent device improving acoustic noise protection during neonatal magnetic resonance imaging.

Authors:  Anders Nordell; Marcus Lundh; Sandra Horsch; Boubou Hallberg; Ulrika Aden; Bo Nordell; Mats Blennow
Journal:  Acta Paediatr       Date:  2009-05-08       Impact factor: 2.299

8.  Characterization of acoustic noise in a neonatal intensive care unit MRI system.

Authors:  Jean A Tkach; Yu Li; Ronald G Pratt; Kelly A Baroch; Wolfgang Loew; Barret R Daniels; Randy O Giaquinto; Stephanie L Merhar; Beth M Kline-Fath; Charles L Dumoulin
Journal:  Pediatr Radiol       Date:  2014-03-05

9.  MRI in the neonatal ICU: initial experience using a small-footprint 1.5-T system.

Authors:  Jean A Tkach; Stephanie L Merhar; Beth M Kline-Fath; Ronald G Pratt; Wolfgang M Loew; Barret R Daniels; Randy O Giaquinto; Mantosh S Rattan; Blaise V Jones; Michael D Taylor; Janice M Tiefermann; Lisa M Tully; E Colleen Murphy; Rachel N Wolf-Severs; Angela A LaRuffa; Charles L Dumoulin
Journal:  AJR Am J Roentgenol       Date:  2014-01       Impact factor: 3.959

  9 in total
  1 in total

1.  Software-based noise reduction in cranial magnetic resonance imaging: Influence on image quality.

Authors:  Philipp Fuelkell; Soenke Langner; Nele Friedrich; Marie-Luise Kromrey; Christoph G Radosa; Ivan Platzek; Birger Mensel; Jens-Peter Kühn
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

  1 in total