Literature DB >> 26456631

Combination of a Sample Pretreatment Microfluidic Device with a Photoluminescent Graphene Oxide Quantum Dot Sensor for Trace Lead Detection.

Minsu Park1, Hyun Dong Ha1, Yong Tae Kim1, Jae Hwan Jung1, Shin-Hyun Kim1, Do Hyun Kim1, Tae Seok Seo1.   

Abstract

A novel trace lead ion (Pb(2+)) detection platform by combining a microfluidic sample pretreatment device with a DNA aptamer linked photoluminescent graphene oxide quantum dot (GOQD) sensor was proposed. The multilayered microdevice included a microchamber which was packed with cation exchange resins for preconcentrating metal ions. The sample loading and recovery were automatically actuated by a peristaltic polydimethylsiloxane micropump with a flow rate of 84 μL/min. Effects of the micropump actuation time, metal ion concentration, pH, and the volumes of the sample and eluent on the metal ion capture and preconcentration efficiency were investigated on a chip. The Pb(2+) samples whose concentrations ranged from 0.48 nM to 1.2 μM were successfully recovered with a preconcentration factor value between 4 and 5. Then, the preconcentrated metal ions were quantitatively analyzed with a DNA aptamer modified GOQD. The DNA aptamer on the GOQD specifically captured the target Pb(2+) which can induce electron transfer from GOQD to Pb(2+) upon UV irradiation, thereby resulting in the fluorescence quenching of the GOQD. The disturbing effect of foreign anions on the Pb(2+) detection and the spiked Pb(2+) real samples were also analyzed. The proposed GOQD metal ion sensor exhibited highly sensitive Pb(2+) detection with a detection limit of 0.64 nM and a dynamic range from 1 to 1000 nM. The on-chip preconcentration of the trace metal ions from a large-volume sample followed by the metal ion detection by the fluorescent GOQD sensor can provide an advanced platform for on-site water pollution screening.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26456631     DOI: 10.1021/acs.analchem.5b02907

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Rapid Enrichment and Sensitive Detection of Multiple Metal Ions Enabled by Macroporous Graphene Foam.

Authors:  Xiaoni Fang; Yang Liu; Luis Jimenez; Yaokai Duan; Gary Brent Adkins; Liang Qiao; Baohong Liu; Wenwan Zhong
Journal:  Anal Chem       Date:  2017-10-27       Impact factor: 6.986

Review 2.  Recent Microdevice-Based Aptamer Sensors.

Authors:  Donny Nugraha Mazaafrianto; Masatoshi Maeki; Akihiko Ishida; Hirofumi Tani; Manabu Tokeshi
Journal:  Micromachines (Basel)       Date:  2018-04-25       Impact factor: 2.891

Review 3.  Bio-Recognition in Spectroscopy-Based Biosensors for *Heavy Metals-Water and Waterborne Contamination Analysis.

Authors:  Alessandra Aloisi; Antonio Della Torre; Angelantonio De Benedetto; Rosaria Rinaldi
Journal:  Biosensors (Basel)       Date:  2019-07-30

Review 4.  Affinity biosensors developed with quantum dots in microfluidic systems.

Authors:  Sultan Şahin; Caner Ünlü; Levent Trabzon
Journal:  Emergent Mater       Date:  2021-03-10

5.  Laser wavelength modulated pulsed laser ablation for selective and efficient production of graphene quantum dots.

Authors:  Sukhyun Kang; Jeong Ho Ryu; Byoungsoo Lee; Kyung Hwan Jung; Kwang Bo Shim; Hyuksu Han; Kang Min Kim
Journal:  RSC Adv       Date:  2019-05-03       Impact factor: 3.361

6.  Interband Absorption in Few-Layer Graphene Quantum Dots: Effect of Heavy Metals.

Authors:  Ivan Shtepliuk; Rositsa Yakimova
Journal:  Materials (Basel)       Date:  2018-07-16       Impact factor: 3.623

Review 7.  Practical Application of Aptamer-Based Biosensors in Detection of Low Molecular Weight Pollutants in Water Sources.

Authors:  Wei Zhang; Qing Xiu Liu; Zhi Hou Guo; Jun Sheng Lin
Journal:  Molecules       Date:  2018-02-07       Impact factor: 4.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.