Literature DB >> 26455556

A fast cross-validation method for alignment of electron tomography images based on Beer-Lambert law.

Rui Yan1, Thomas J Edwards1, Logan M Pankratz1, Richard J Kuhn1, Jason K Lanman1, Jun Liu2, Wen Jiang3.   

Abstract

In electron tomography, accurate alignment of tilt series is an essential step in attaining high-resolution 3D reconstructions. Nevertheless, quantitative assessment of alignment quality has remained a challenging issue, even though many alignment methods have been reported. Here, we report a fast and accurate method, tomoAlignEval, based on the Beer-Lambert law, for the evaluation of alignment quality. Our method is able to globally estimate the alignment accuracy by measuring the goodness of log-linear relationship of the beam intensity attenuations at different tilt angles. Extensive tests with experimental data demonstrated its robust performance with stained and cryo samples. Our method is not only significantly faster but also more sensitive than measurements of tomogram resolution using Fourier shell correlation method (FSCe/o). From these tests, we also conclude that while current alignment methods are sufficiently accurate for stained samples, inaccurate alignments remain a major limitation for high resolution cryo-electron tomography.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Alignment accuracy; Beer–Lambert law; Cross validation; Electron tomography; Inelastic scattering; Least square fitting

Mesh:

Year:  2015        PMID: 26455556      PMCID: PMC4633358          DOI: 10.1016/j.jsb.2015.10.004

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  16 in total

1.  Efficiency of 2D alignment methods.

Authors:  Laurent Joyeux; Pawel A Penczek
Journal:  Ultramicroscopy       Date:  2002-07       Impact factor: 2.689

2.  A resolution criterion for electron tomography based on cross-validation.

Authors:  Giovanni Cardone; Kay Grünewald; Alasdair C Steven
Journal:  J Struct Biol       Date:  2005-08       Impact factor: 2.867

3.  Automatic TEM image alignment by trifocal geometry.

Authors:  S S Brandt; U Ziese
Journal:  J Microsc       Date:  2006-04       Impact factor: 1.758

4.  Quantifying resolution limiting factors in subtomogram averaged cryo-electron tomography using simulations.

Authors:  Lenard M Voortman; Miloš Vulović; Massimiliano Maletta; Andreas Voigt; Erik M Franken; Angelita Simonetti; Peter J Peters; Lucas J van Vliet; Bernd Rieger
Journal:  J Struct Biol       Date:  2014-07-03       Impact factor: 2.867

5.  Local thickness measurement through scattering contrast and electron energy-loss spectroscopy.

Authors:  Huai-Ruo Zhang; Ray F Egerton; Marek Malac
Journal:  Micron       Date:  2011-07-14       Impact factor: 2.251

6.  A marker-free automatic alignment method based on scale-invariant features.

Authors:  Renmin Han; Fa Zhang; Xiaohua Wan; Jose-Jesus Fernández; Fei Sun; Zhiyong Liu
Journal:  J Struct Biol       Date:  2014-02-27       Impact factor: 2.867

7.  EELS log-ratio technique for specimen-thickness measurement in the TEM.

Authors:  T Malis; S C Cheng; R F Egerton
Journal:  J Electron Microsc Tech       Date:  1988-02

8.  Protein secondary structure determination by constrained single-particle cryo-electron tomography.

Authors:  Alberto Bartesaghi; Federico Lecumberry; Guillermo Sapiro; Sriram Subramaniam
Journal:  Structure       Date:  2012-12-05       Impact factor: 5.006

Review 9.  The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological molecules.

Authors:  R Henderson
Journal:  Q Rev Biophys       Date:  1995-05       Impact factor: 5.318

10.  A dose-rate effect in single-particle electron microscopy.

Authors:  James Z Chen; Carsten Sachse; Chen Xu; Thorsten Mielke; Christian M T Spahn; Nikolaus Grigorieff
Journal:  J Struct Biol       Date:  2007-10-01       Impact factor: 2.867

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.