Literature DB >> 26454242

Correcting Interdevice Bias of Horizontal White-to-White and Sulcus-to-Sulcus Measures Used for Implantable Collamer Lens Sizing.

Ivo Guber1, Ciara Bergin1, Sylvie Perritaz1, François Majo2.   

Abstract

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection.
DESIGN: Interinstrument reliability and bias assessment study.
METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated.
RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph.
CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26454242     DOI: 10.1016/j.ajo.2015.09.037

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

2.  Inter-Eye Vault Differences of Implantable Collamer Lens Measured Using Anterior Segment Optical Coherence Tomography.

Authors:  Santiago Cerpa Manito; Angel Sánchez Trancón; Oscar Torrado Sierra; António M G Baptista; Pedro Miguel Serra
Journal:  Clin Ophthalmol       Date:  2020-10-29

Review 3.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

4.  Confounding sizing in posterior chamber phakic lens selection due to white-to-white measurement bias.

Authors:  JoaquIn Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; Elisa Hueso; David P Piñero
Journal:  Indian J Ophthalmol       Date:  2019-03       Impact factor: 1.848

5.  Phakic intraocular lens: Getting the right size.

Authors:  Kalyaani Deshpande; Rushad Shroff; Partha Biswas; Kamal Kapur; Naren Shetty; Ann Sarah Koshy; Pooja Khamar
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

6.  Agreement of implantable collamer lens sizes using parameters from different devices.

Authors:  Manachai Nonpassopon; Passara Jongkhajornpong; Prae Phimpho; Nontawat Cheewaruangroj; Kaevalin Lekhanont; Varintorn Chuckpaiwong
Journal:  BMJ Open Ophthalmol       Date:  2022-03-08

7.  Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography.

Authors:  Soyoung Ryu; Sook Hyun Yoon; Ikhyun Jun; Kyoung Yul Seo; Eung Kweon Kim; Tae-Im Kim
Journal:  Korean J Ophthalmol       Date:  2022-05-06

8.  A prediction model for sulcus-to-sulcus diameter in myopic eyes: a 1466-sample retrospective study.

Authors:  Qiu-Jian Zhu; Wei-Jian Zhu; Wen-Jing Chen; Lie Ma; You Yuan
Journal:  BMC Ophthalmol       Date:  2022-07-16       Impact factor: 2.086

9.  Comparison of white-to-white measurements using four devices and their determination of ICL sizing.

Authors:  Robert Edward T Ang; Edward Kenneth F Reyes; Fernando Amado J Ayuyao; Maria Isabel N Umali; Emerson M Cruz
Journal:  Eye Vis (Lond)       Date:  2022-10-02

Review 10.  Nanophthalmos: A Review of the Clinical Spectrum and Genetics.

Authors:  Pedro C Carricondo; Thais Andrade; Lev Prasov; Bernadete M Ayres; Sayoko E Moroi
Journal:  J Ophthalmol       Date:  2018-05-09       Impact factor: 1.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.