Literature DB >> 25829548

An acoustic filter based on layered structure.

Jianguo Ma, Michael B Steer1, Xiaoning Jiang2.   

Abstract

Acoustic filters (AFs) are key components to control wave propagation in multi-frequency systems. We present a design which selectively achieves acoustic filtering with a stop band and passive amplification at the high- and low-frequencies, respectively. Measurement results from the prototypes closely match the design predictions. The AF suppresses the high frequency aliasing echo by 14.5 dB and amplifies the low frequency transmission by 8.0 dB, increasing an axial resolution from 416 to 86 μm in imaging. The AF design approach is proved to be effective in multi-frequency systems.

Entities:  

Year:  2015        PMID: 25829548      PMCID: PMC4368588          DOI: 10.1063/1.4915100

Source DB:  PubMed          Journal:  Appl Phys Lett        ISSN: 0003-6951            Impact factor:   3.791


  12 in total

1.  Super harmonic imaging: a new imaging technique for improved contrast detection.

Authors:  Ayache Bouakaz; Sigmund Frigstad; Folkert J Ten Cate; Nico de Jong
Journal:  Ultrasound Med Biol       Date:  2002-01       Impact factor: 2.998

2.  Anisotropic metamaterials for full control of acoustic waves.

Authors:  Johan Christensen; F Javier García de Abajo
Journal:  Phys Rev Lett       Date:  2012-03-23       Impact factor: 9.161

3.  Dual-frequency ultrasound imaging and therapeutic bilaminar array using frequency selective isolation layer.

Authors:  Takashi Azuma; Makoto Ogihara; Jun Kubota; Akira Sasaki; Shin-ichiro Umemura; Hiroshi Furuhata
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-05       Impact factor: 2.725

4.  An acoustic rectifier.

Authors:  B Liang; X S Guo; J Tu; D Zhang; J C Cheng
Journal:  Nat Mater       Date:  2010-10-24       Impact factor: 43.841

5.  Design of ultrasonic transducers with multiple acoustic matching layers for medical application.

Authors:  T Inoue; M Ohta; S Takahashi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1987       Impact factor: 2.725

6.  Tunable unidirectional sound propagation through a sonic-crystal-based acoustic diode.

Authors:  Xue-Feng Li; Xu Ni; Liang Feng; Ming-Hui Lu; Cheng He; Yan-Feng Chen
Journal:  Phys Rev Lett       Date:  2011-02-23       Impact factor: 9.161

7.  Ultrasonic two-dimensional visualization for medical diagnosis.

Authors:  G Kossoff; D E Robinson; W J Garrett
Journal:  J Acoust Soc Am       Date:  1968-11       Impact factor: 1.840

8.  Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography.

Authors:  Jianguo Ma; K Heath Martin; Yang Li; Paul A Dayton; K Kirk Shung; Qifa Zhou; Xiaoning Jiang
Journal:  Phys Med Biol       Date:  2015-04-09       Impact factor: 3.609

9.  A preliminary engineering design of intravascular dual-frequency transducers for contrast-enhanced acoustic angiography and molecular imaging.

Authors:  Jianguo Ma; K Martin; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-05       Impact factor: 2.725

10.  Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Mike Lee; Sibo Li; F Stuart Foster; Xiaoning Jiang; Paul A Dayton
Journal:  Sensors (Basel)       Date:  2014-11-04       Impact factor: 3.576

View more
  10 in total

1.  Design of matching layers for high-frequency ultrasonic transducers.

Authors:  Chunlong Fei; Jianguo Ma; Chi Tat Chiu; Jay A Williams; Wayne Fong; Zeyu Chen; BenPeng Zhu; Rui Xiong; Jing Shi; Tzung K Hsiai; K Kirk Shung; Qifa Zhou
Journal:  Appl Phys Lett       Date:  2015-09-24       Impact factor: 3.791

2.  Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography.

Authors:  Jianguo Ma; K Heath Martin; Yang Li; Paul A Dayton; K Kirk Shung; Qifa Zhou; Xiaoning Jiang
Journal:  Phys Med Biol       Date:  2015-04-09       Impact factor: 3.609

3.  Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

Authors:  Brooks D Lindsey; Jinwook Kim; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-08       Impact factor: 2.725

4.  Ultrasonic Transducer-Guided Electrochemical Impedance Spectroscopy to Assess Lipid-Laden Plaques.

Authors:  Jianguo Ma; Yuan Luo; René R Sevag Packard; Teng Ma; Yichen Ding; Parinaz Abiri; Yu-Chong Tai; Qifa Zhou; Kirk K Shung; Rongsong Li; Tzung Hsiai
Journal:  Sens Actuators B Chem       Date:  2016-05-07       Impact factor: 7.460

5.  Contrast Enhanced Superharmonic Imaging for Acoustic Angiography Using Reduced Form-Factor Lateral Mode Transmitters for Intravascular and Intracavity Applications.

Authors:  Zhuochen Wang; K Heath Martin; Wenbin Huang; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-10-20       Impact factor: 2.725

6.  A Dual-Frequency Colinear Array for Acoustic Angiography in Prostate Cancer Evaluation.

Authors:  Sibo Li; Jinwook Kim; Zhuochen Wang; Sandeep Kasoji; Brooks D Lindsey; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

7.  Ultrafast broadband nonlinear optical properties and excited-state dynamics of two bis-chalcone derivatives.

Authors:  Lei Shen; Zhongguo Li; Xingzhi Wu; Wenfa Zhou; Junyi Yang; Yinglin Song
Journal:  RSC Adv       Date:  2020-04-17       Impact factor: 4.036

8.  Ex Vivo Porcine Arterial and Chorioallantoic Membrane Acoustic Angiography Using Dual-Frequency Intravascular Ultrasound Probes.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Timothy C Nichols; Xiaoning Jiang; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2016-05-31       Impact factor: 2.998

Review 9.  Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.

Authors:  Chang Peng; Huaiyu Wu; Seungsoo Kim; Xuming Dai; Xiaoning Jiang
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.847

10.  3D Smith charts scattering parameters frequency-dependent orientation analysis and complex-scalar multi-parameter characterization applied to Peano reconfigurable vanadium dioxide inductors.

Authors:  Andrei A Muller; Alin Moldoveanu; Victor Asavei; Riyaz A Khadar; Esther Sanabria-Codesal; Anna Krammer; Montserrat Fernandez-Bolaños; Matteo Cavalieri; Junrui Zhang; Emanuele Casu; Andreas Schuler; Adrian M Ionescu
Journal:  Sci Rep       Date:  2019-12-04       Impact factor: 4.379

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.