Literature DB >> 26443975

Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study.

Leila Rahnama1, Asghar Rezasoltani2, Minoo Khalkhali-Zavieh3, Behnam Rahnama4, Farhang Noori-Kochi5.   

Abstract

OBJECTIVES: This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals.
METHOD: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter-session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively.
RESULTS: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects.
CONCLUSIONS: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain.

Entities:  

Mesh:

Year:  2015        PMID: 26443975      PMCID: PMC4620976          DOI: 10.1590/bjpt-rbf.2014.0097

Source DB:  PubMed          Journal:  Braz J Phys Ther        ISSN: 1413-3555            Impact factor:   3.377


  27 in total

1.  Muscle activity onset in the lumbar multifidus muscle recorded simultaneously by ultrasound imaging and intramuscular electromyography.

Authors:  Ottar Vasseljen; Haldis Haug Dahl; Paul Jarle Mork; Hans G Torp
Journal:  Clin Biomech (Bristol, Avon)       Date:  2006-07-05       Impact factor: 2.063

2.  Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults.

Authors:  Jo-Ping Lee; Wen-Yih I Tseng; Yio-Wha Shau; Chung-Li Wang; Hsing-Kuo Wang; Shwu-Fen Wang
Journal:  Man Ther       Date:  2006-09-20

3.  MRI study of the cross-sectional area for the cervical extensor musculature in patients with persistent whiplash associated disorders (WAD).

Authors:  James Elliott; Gwendolen Jull; Jon Timothy Noteboom; Graham Galloway
Journal:  Man Ther       Date:  2007-03-26

4.  Intrarater and interrater reliability of assessment of lumbar multifidus muscle thickness using rehabilitative ultrasound imaging.

Authors:  Tracy L Wallwork; Julie A Hides; Warren R Stanton
Journal:  J Orthop Sports Phys Ther       Date:  2007-10       Impact factor: 4.751

5.  Ultrasound imaging assessment of abdominal muscle function during drawing-in of the abdominal wall: an intrarater reliability study.

Authors:  Julie A Hides; Tanja Miokovic; Daniel L Belavý; Warren R Stanton; Carolyn A Richardson
Journal:  J Orthop Sports Phys Ther       Date:  2007-08       Impact factor: 4.751

6.  Validity and reliability of ultrasonography for the longus colli in asymptomatic subjects.

Authors:  Barbara Cagnie; Erwin Derese; Leen Vandamme; Koenraad Verstraete; Dirk Cambier; Lieven Danneels
Journal:  Man Ther       Date:  2008-09-30

7.  The effects of isometric contraction of shoulder muscles on cervical multifidus muscle dimensions in healthy office workers.

Authors:  Leila Rahnama; Asghar Rezasoltani; Minoo Khalkhali Zavieh; Farhang Noori Kochi; Alireza Akbarzadeh Baghban
Journal:  J Bodyw Mov Ther       Date:  2013-11-10

8.  Reliability of thickness measurements of the dorsal muscles of the upper cervical spine: an ultrasonographic study.

Authors:  Ya-Jung Lin; Huei-Ming Chai; Shwu-Fen Wang
Journal:  J Orthop Sports Phys Ther       Date:  2009-12       Impact factor: 4.751

9.  Measurement of cervical multifidus contraction pattern with ultrasound imaging.

Authors:  Jo-Ping Lee; Chung-Li Wang; Yio-Wha Shau; Shwu-Fen Wang
Journal:  J Electromyogr Kinesiol       Date:  2008-01-22       Impact factor: 2.368

10.  Reliability of rehabilitative ultrasound imaging of the transversus abdominis and lumbar multifidus muscles.

Authors:  Shane L Koppenhaver; Jeffrey J Hebert; Julie M Fritz; Eric C Parent; Deydre S Teyhen; John S Magel
Journal:  Arch Phys Med Rehabil       Date:  2009-01       Impact factor: 3.966

View more
  1 in total

1.  Comparison of cervical muscle thickness between asymptomatic women with and without forward head posture.

Authors:  Fateme Bokaee; Asghar Rezasoltani; Farideh D Manshadi; Sedigheh S Naimi; Alireza A Baghban; Hadi Azimi
Journal:  Braz J Phys Ther       Date:  2017-04-19       Impact factor: 3.377

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.