Literature DB >> 16987692

Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults.

Jo-Ping Lee1, Wen-Yih I Tseng, Yio-Wha Shau, Chung-Li Wang, Hsing-Kuo Wang, Shwu-Fen Wang.   

Abstract

The deep muscles that play significant roles in maintaining segmental stability have been measured using ultrasonography (US). However, few studies have been carried out to determine the reliability and validity of US for measuring the cervical multifidus during contraction. The aims of this investigation were to evaluate the reliability of the dimensions of the cervical multifidus as measured using US and compare the US measurements with those determined with magnetic resonance imaging (MRI), the gold standard. Ten asymptomatic adult subjects (age, 28.5+/-3.5 years) participated in testing-retesting of muscle dimensions at rest and during isometric head extension with the cranio-cervical spine maintained in a flexed position against individual maximum resistance. Ten asymptomatic adult subjects (age, 28.1+/-4.1 years) participated in testing to compare US and MRI measurements of the thickness, width, area, and shape ratio of the cervical multifidus at the C4, C5, and C6 levels. US measurements of muscle thickness at the C4, C5, and C6 levels at rest were 0.67+/-0.14, 0.70+/-0.20 and 0.73+/-0.09 cm, respectively; the corresponding measurements as determined by MRI were 0.70+/-0.12, 0.67+/-0.15 and 0.70+/-0.06 cm. The within-subject coefficient of variation (CV(w)) for thickness at rest and during contraction was less than 10%, indicating acceptable reliability. US measurement of thickness had better reliability and validity. The range of limit of agreement for muscle thickness at the C4, C5, and C6 levels was -0.20 to 0.20 cm, and the range of R(2) was 0.42-0.64. The thickness of the cervical multifidus muscle increased significantly during contraction (1.13+/-0.20, 1.19+/-0.20 and 1.17+/-0.12 cm for the C4, C5, and C6 levels, P<0.05). However, no significant differences were noted among the three levels. The results indicate that US can detect changes in segmental cervical multifidus during contraction.

Mesh:

Year:  2006        PMID: 16987692     DOI: 10.1016/j.math.2006.07.008

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  12 in total

1.  Recruitment of motor units in two fascicles of the semispinalis cervicis muscle.

Authors:  Jochen Schomacher; Jakob Lund Dideriksen; Dario Farina; Deborah Falla
Journal:  J Neurophysiol       Date:  2012-03-07       Impact factor: 2.714

2.  Ultrasonographic measurement of neck muscle recruitment: a preliminary investigation.

Authors:  Fabianna M R Jesus; Paulo H Ferreira; Manuela L Ferreira
Journal:  J Man Manip Ther       Date:  2008

Review 3.  Ultrasound diagnosis and therapeutic intervention in the spine.

Authors:  Adil S Ahmed; Raahul Ramakrishnan; Vignesh Ramachandran; Shyam S Ramachandran; Kevin Phan; Erik L Antonsen
Journal:  J Spine Surg       Date:  2018-06

4.  Validity of Ultrasound Imaging Versus Magnetic Resonance Imaging for Measuring Anterior Thigh Muscle, Subcutaneous Fat, and Fascia Thickness.

Authors:  Filippo Mechelli; Lars Arendt-Nielsen; Maria Stokes; Sandra Agyapong-Badu
Journal:  Methods Protoc       Date:  2019-07-10

5.  Ultrasonography for the assessment of the upper trapezius properties in healthy females: a reliability study.

Authors:  Hakimeh Adigozali; Azadeh Shadmehr; Esmail Ebrahimi; Asghar Rezasoltani; Farrokh Naderi
Journal:  Muscles Ligaments Tendons J       Date:  2016-05-19

6.  THE COMPARISON OF THE LUMBAR MULTIFIDUS MUSCLES FUNCTION BETWEEN GYMNASTIC ATHLETES WITH SWAY-BACK POSTURE AND NORMAL POSTURE.

Authors:  Elnaz Mahdavie; Asghar Rezasoltani; Leila Simorgh
Journal:  Int J Sports Phys Ther       Date:  2017-08

Review 7.  Human skeletal muscle size with ultrasound imaging: a comprehensive review.

Authors:  Masatoshi Naruse; Scott Trappe; Todd A Trappe
Journal:  J Appl Physiol (1985)       Date:  2022-03-31

8.  Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study.

Authors:  Leila Rahnama; Asghar Rezasoltani; Minoo Khalkhali-Zavieh; Behnam Rahnama; Farhang Noori-Kochi
Journal:  Braz J Phys Ther       Date:  2015-09-01       Impact factor: 3.377

9.  Musculoskeletal diagnostic ultrasound imaging for thickness measurement of four principal muscles of the cervical spine -a reliability and agreement study.

Authors:  Cecilie Krage Øverås; Birgitte Lawaetz Myhrvold; Gro Røsok; Eli Magnesen
Journal:  Chiropr Man Therap       Date:  2017-01-04

10.  Comparison of the Abdominal Wall Muscle Thickness in Female Rugby Players Versus Non-Athletic Women: A Cross-Sectional Study.

Authors:  Vanesa Abuín-Porras; Mónica de la Cueva-Reguera; Pedro Benavides-Morales; Rocío Ávila-Pérez; Blanca de la Cruz-Torres; Helios Pareja-Galeano; María Blanco-Morales; Carlos Romero-Morales
Journal:  Medicina (Kaunas)       Date:  2019-12-25       Impact factor: 2.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.