Ultrasound imaging assessment of abdominal muscle function during drawing-in of the abdominal wall: an intrarater reliability study.

Julie A Hides1, Tanja Miokovic, Daniel L Belavý, Warren R Stanton, Carolyn A Richardson.   

Abstract

STUDY
DESIGN: Test-retest intrarater reliability study.
OBJECTIVE: To examine reliability of abdominal musculature measurements across a broad range of conditions for a physical therapist newly trained in assessment using rehabilitative ultrasound imaging (RUSI).
BACKGROUND: RUSI has previously been used to assess abdominal muscle function during a drawing-in maneuver of the anterior abdominal wall, and measurements conducted by an experienced assessor have been validated by comparison with magnetic resonance imaging. Few studies have examined the reliability of less experienced operators, and only in isolated measurement conditions. METHODS AND MEASURES: Nineteen subjects (11 female, 8 male) without a history of low back pain performed the abdominal drawing-in maneuver in a supine hook-lying position. RUSI was used bilaterally to assess the thickness of the internal oblique (IO) and transversus abdominis (TrA) muscles at rest and on contraction, as well as changes in the length of the TrA muscle (indicated by slide of the anterior abdominal fascia). The reliability of a novice rater who received 8 hours of training was examined (a) across 3 measurements of the same ultrasound image, (b) across 3 separate ultrasound images (averaged for days and sides of abdomen), and (c) across 2 days (averaged for images and sides).
RESULTS: Reliability of assessing muscle thickness was very high across 3 measurements of the sale image (intrarater correlation coefficients [ICC3.1] were all greater than 0.97), fair to high across 3 images (ICC(3,4) = 0.62-0.82), and fair to high across 2 days (ICC(3,6) = 0.63-0.85). Reliability of measuring the slide of the anterior abdominal fascia was very high across measurements from the same image (ICC(3,1) = 0.98) but very low across images (ICC(3,4) = 0.44) and across 2 days (ICC(3,6) = 0.36).
CONCLUSIONS: High reliability of a novice rater was demonstrated for some measurement conditions. Measures of reliability for recapturing the image and repetition across days ranged from low to high. Inconsistencies in the pattern of results suggest that for a novice assessor using RUSI, training should be performed and reliability assessed for each abdominal muscle and measurement condition intended to be used for research and clinical practice.

Entities:  

Mesh:

Year:  2007        PMID: 17877284     DOI: 10.2519/jospt.2007.2416

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  30 in total

1.  Reliability of real-time ultrasound measurement of transversus abdominis thickness in healthy trained subjects.

Authors:  Rafael Gnat; Edward Saulicz; Barbara Miądowicz
Journal:  Eur Spine J       Date:  2012-02-12       Impact factor: 3.134

2.  Changes in multifidus and abdominal muscle size in response to microgravity: possible implications for low back pain research.

Authors:  J A Hides; G Lambrecht; W R Stanton; V Damann
Journal:  Eur Spine J       Date:  2015-11-18       Impact factor: 3.134

3.  Differences in transverse abdominis activation with stable and unstable bridging exercises in individuals with low back pain.

Authors:  Susan A Saliba; Ted Croy; Rebecca Guthrie; Dustin Grooms; Arthur Weltman; Terry L Grindstaff
Journal:  N Am J Sports Phys Ther       Date:  2010-06

4.  The Effect of Additional External Resistance on Inter-Set Changes in Abdominal Muscle Thickness during Bridging Exercise.

Authors:  Kostantinos Dafkou; Eleftherios Kellis; Athanasios Ellinoudis; Chrysostomos Sahinis
Journal:  J Sports Sci Med       Date:  2020-02-24       Impact factor: 2.988

5.  Transversus Abdominis and Lumbar Multifidus Thickness Among Three Dance Positions in Argentine Tango Dancers.

Authors:  Eleni Gouridou; Eleftherios Kellis; Ermioni Katartzi; Nikolaos Kofotolis
Journal:  Int J Exerc Sci       Date:  2021-04-01

6.  The effect of food consumption on the thickness of abdominal muscles, employing ultrasound measurements.

Authors:  Ramin Kordi; Mohsen Rostami; Pardis Noormohammadpour; Mohammad Ali Mansournia
Journal:  Eur Spine J       Date:  2011-02-12       Impact factor: 3.134

7.  Reliability and Validity of Standing Back Extension Test for Detecting Motor Control Impairment in Subjects with Low Back Pain.

Authors:  Gauri A Gondhalekar; Senthil P Kumar; Charu Eapen; Ajit Mahale
Journal:  J Clin Diagn Res       Date:  2016-01-01

8.  [Functional diagnostics of mobility control, mobility stabilization and hypermobility. Reliability of clinical tests - results of a multicenter study].

Authors:  K Niemier; S Schmidt; K Engel; A Steinmetz; K Herms; Ka Herms; V Liefring; A Maulhardt; T Wetterling; S Kosup; R Casser; G Jäger; S Törkott; K Bieneck; G Rotter; U Marnitz; A Klein; S Jahr; A Reishauer; W Seidel
Journal:  Orthopade       Date:  2009-07-18       Impact factor: 1.087

9.  Cocontraction of ankle dorsiflexors and transversus abdominis function in patients with low back pain.

Authors:  Seung-Chul Chon; Joshua H You; Susan A Saliba
Journal:  J Athl Train       Date:  2012 Jul-Aug       Impact factor: 2.860

10.  Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study.

Authors:  Leila Rahnama; Asghar Rezasoltani; Minoo Khalkhali-Zavieh; Behnam Rahnama; Farhang Noori-Kochi
Journal:  Braz J Phys Ther       Date:  2015-09-01       Impact factor: 3.377

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.