Literature DB >> 26435941

Evaluation of LAMP Assay Using Phenotypic Tests and Conventional PCR for Detection of nuc and mecA genes Among Clinical Isolates of Staphylococcus spp.

Sukanya Sudhaharan1, Lavanya Vanjari2, Neeraja Mamidi2, Nagapriyanka Ede2, Lakshmi Vemu3.   

Abstract

INTRODUCTION: The purpose of this study is to develop a nuc and mecA gene specific Loop-mediated isothermal Amplification (LAMP) assay for rapid identification and detection of methicillin resistant Staphylococcus aureus among clinical isolates.
MATERIALS AND METHODS: A total of 100 (70 from pus and 30 from blood), clinical isolates of Staphylococcus spp were screened for the nuc gene to differentiate between S.aureus and Coagulase negative Staphylococci (CONS) by a nuc gene specific LAMP assay. The isolates were also screened for the presence of the mec Agene by the mecA specific LAMP assay. The results were compared with the phenotypic identification and methicillin resistance by Vitek-2 system (bioMérieux, Marcy l'Etoile, France) and conventional PCR.
RESULTS: Among 100 Staphylococcus isolates, there were 82 (82%) Staphylococcus aureus isolates and 18 (18%) coagulase negative Staphylococcus as detected by the Vitek 2, conventional PCR and the LAMP assay using the nuc gene. The mecA gene was detected by the LAMP assay in 56(56%) isolates (44 Methicillin resistant Staphylococcus aureus (MRSA) and 12 Methicillin resistant coagulase negative Staphylococcus (MRCONS), which were also identified by the Vitek 2 and conventional PCR as methicillin resistant. The results of the LAMP assay were available within 90min as compared to the Vitek 2 results (18- 24hours) and conventional PCR (3-4 hours).
CONCLUSION: The present study proved that LAMP assay can be used for the simultaneous differentiation of Staphylococcal spp and detection of methicillin resistance.

Entities:  

Keywords:  Benchside assay; Methicillin resistance; Turnaround time; Vitek 2

Year:  2015        PMID: 26435941      PMCID: PMC4576532          DOI: 10.7860/JCDR/2015/13962.6315

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  20 in total

1.  Loop-mediated isothermal amplification of DNA.

Authors:  T Notomi; H Okayama; H Masubuchi; T Yonekawa; K Watanabe; N Amino; T Hase
Journal:  Nucleic Acids Res       Date:  2000-06-15       Impact factor: 16.971

2.  Development of a triplex real-time PCR assay for detection of Panton-Valentine leukocidin toxin genes in clinical isolates of methicillin-resistant Staphylococcus aureus.

Authors:  Ryan R McDonald; Nick A Antonishyn; Toni Hansen; Laelie A Snook; Evelyn Nagle; Michael R Mulvey; Paul N Levett; Greg B Horsman
Journal:  J Clin Microbiol       Date:  2005-12       Impact factor: 5.948

3.  Structural comparison of three types of staphylococcal cassette chromosome mec integrated in the chromosome in methicillin-resistant Staphylococcus aureus.

Authors:  T Ito; Y Katayama; K Asada; N Mori; K Tsutsumimoto; C Tiensasitorn; K Hiramatsu
Journal:  Antimicrob Agents Chemother       Date:  2001-05       Impact factor: 5.191

4.  Loop-mediated isothermal amplification assay targeting the femA gene for rapid detection of Staphylococcus aureus from clinical and food samples.

Authors:  Xihong Zhao; Yanmei Li; Myoungsu Park; Jun Wang; Youhong Zhang; Xiaowei He; Fereidoun Forghani; Li Wang; Guangchao Yu; Deog-Hwan Oh
Journal:  J Microbiol Biotechnol       Date:  2013-02       Impact factor: 2.351

5.  Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products.

Authors:  Norihiro Tomita; Yasuyoshi Mori; Hidetoshi Kanda; Tsugunori Notomi
Journal:  Nat Protoc       Date:  2008       Impact factor: 13.491

6.  New real-time PCR assay for rapid detection of methicillin-resistant Staphylococcus aureus directly from specimens containing a mixture of staphylococci.

Authors:  A Huletsky; R Giroux; V Rossbach; M Gagnon; M Vaillancourt; M Bernier; F Gagnon; K Truchon; M Bastien; F J Picard; A van Belkum; M Ouellette; P H Roy; M G Bergeron
Journal:  J Clin Microbiol       Date:  2004-05       Impact factor: 5.948

7.  Application of loop-mediated isothermal amplification technique to rapid and direct detection of methicillin-resistant Staphylococcus aureus (MRSA) in blood cultures.

Authors:  Yoshiki Misawa; Atsushi Yoshida; Ryoichi Saito; Honami Yoshida; Katsuko Okuzumi; Nobue Ito; Mitsumasa Okada; Kyoji Moriya; Kazuhiko Koike
Journal:  J Infect Chemother       Date:  2007-06-21       Impact factor: 2.211

8.  A comparison of PCR detection of mecA with oxacillin disk susceptibility testing in different media and sceptor automated system for both Staphylococcus aureus and coagulase-negative staphylococci isolates.

Authors:  S Ercis; B Sancak; G Hasçelik
Journal:  Indian J Med Microbiol       Date:  2008 Jan-Mar       Impact factor: 0.985

9.  Rapid and simple detection of methicillin-resistance Staphylococcus aureus by orfX loop-mediated isothermal amplification assay.

Authors:  Jianyu Su; Xiaochen Liu; Hemiao Cui; Yanyan Li; Dingqiang Chen; Yanmei Li; Guangchao Yu
Journal:  BMC Biotechnol       Date:  2014-01-24       Impact factor: 2.563

10.  Loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus aureus.

Authors:  King Ting Lim; Cindy Shuan Ju Teh; Kwai Lin Thong
Journal:  Biomed Res Int       Date:  2013-01-15       Impact factor: 3.411

View more
  7 in total

1.  Facile silicification of plastic surface for bioassays.

Authors:  Seonki Hong; Ki Soo Park; Ralph Weissleder; Cesar M Castro; Hakho Lee
Journal:  Chem Commun (Camb)       Date:  2017-02-09       Impact factor: 6.222

2.  Identification of Methicillin-Resistant Staphylococcus aureus (MRSA) Using Simultaneous Detection of mecA, nuc, and femB by Loop-Mediated Isothermal Amplification (LAMP).

Authors:  Changguo Chen; Qiangyuan Zhao; Jianwei Guo; Yanjun Li; Qiuyuan Chen
Journal:  Curr Microbiol       Date:  2017-06-02       Impact factor: 2.188

3.  Fluorescent Detection of Methicillin Resistant Staphylococcus aureus by Loop-mediated Isothermal Amplification Assisted with Streptavidin-coated Quantum Dots.

Authors:  Aily Aliasgharian; Pooria Gill; Mohammad Ahanjan; Adele Rafati
Journal:  Avicenna J Med Biotechnol       Date:  2022 Jan-Mar

4.  Direct loop-mediated isothermal amplification assay for on-site detection of Staphylococcus aureus.

Authors:  Xiaolan Tian; Junli Feng; Yi Wang
Journal:  FEMS Microbiol Lett       Date:  2018-06-01       Impact factor: 2.742

5.  Antibiogram and phylogenetic diversity of enterotoxigenic Staphylococcus aureus strains from milk products and public health implications.

Authors:  Eman E Abdeen; Walid S Mousa; Sarah Y Abdel Salam; Khalid S Al-Maary; Ayman S Mubarak; Ihab M Moussa; Hassan A Hemeg; Abdulaziz M Almuzaini; Ahmed I Alajaji; Roua Abdullah Alsubki; Ayman Elbehiry
Journal:  Saudi J Biol Sci       Date:  2020-06-24       Impact factor: 4.219

6.  A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection.

Authors:  Veronica L Fowler; Bryony Armson; Jose L Gonzales; Emma L Wise; Emma L A Howson; Zoe Vincent-Mistiaen; Sarah Fouch; Connor J Maltby; Seden Grippon; Simon Munro; Lisa Jones; Tom Holmes; Claire Tillyer; Joanne Elwell; Amy Sowood; Oliver de Peyer; Sophie Dixon; Thomas Hatcher; Helen Patrick; Shailen Laxman; Charlotte Walsh; Michael Andreou; Nick Morant; Duncan Clark; Nathan Moore; Rebecca Houghton; Nicholas J Cortes; Stephen P Kidd
Journal:  J Infect       Date:  2020-11-30       Impact factor: 6.072

7.  The application of the loop-mediated isothermal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus.

Authors:  A D Khosravi; S Khoshnood; E Abbasi Montazeri; N Jomehzadeh; M Moradi; F Shahi
Journal:  New Microbes New Infect       Date:  2022-01-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.