Literature DB >> 26432124

Effect of tear osmolarity on repeatability of keratometry for cataract surgery planning.

Alice T Epitropoulos1, Cynthia Matossian1, Gregg J Berdy1, Ranjan P Malhotra1, Richard Potvin2.   

Abstract

PURPOSE: To evaluate the effects of tear osmolarity on the repeatability of keratometry (K) measurements in patients presenting for cataract surgery.
SETTING: Three clinical practices.
DESIGN: Observational prospective nonrandomized study.
METHODS: Subjects were prospectively recruited based on tear osmolarity (Tearlab Osmolarity System); that is, osmolarity more than 316 mOsm/L in at least 1 eye (hyperosmolar) and osmolarity less than 308 mOsm/L in both eyes (normal). The baseline K value was measured, and a second measurement was taken on the same instrument (IOLMaster) within 3 weeks of the first. Variability in average K, calculated corneal astigmatism using vector analysis, and intraocular lens (IOL) sphere power calculations were compared between groups.
RESULTS: The hyperosmolar group (50 subjects) had a statistically significantly higher variability in the average K reading (P = .05) than the normal group (25 subjects) and a statistically significantly higher percentage of eyes with a 1.0 diopter (D) or greater difference in the measured corneal astigmatism (P = .02). A statistically significantly higher percentage of eyes in the hyperosmolar group had an IOL power difference of more than 0.5 D (P = .02). No statistically significant differences were present when the subjects were grouped by self-reported dry eye.
CONCLUSIONS: Significantly more variability in average K and anterior corneal astigmatism was observed in the hyperosmolar group, with significant resultant differences in IOL power calculations. Variability was not significantly different when subjects were grouped by self-reported dry eye. Measurement of tear osmolarity at the time of cataract surgery planning can effectively identify patients with a higher likelihood of high unexpected refractive error resulting from inaccurate keratometry. FINANCIAL DISCLOSURE: Drs. Epitropoulos, Matossian, Berdy, and Malhotra received compensation from Tearlab for participating in the study. No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26432124     DOI: 10.1016/j.jcrs.2015.01.016

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  32 in total

1.  Corneal surgically induced astigmatism in resident surgeons.

Authors:  Timothy Sipos; Kendall Bicknell
Journal:  Proc (Bayl Univ Med Cent)       Date:  2021-10-04

2.  Evaluation of the repeatability of optical coherence tomography in patients with age-related cataract associated with dry eye.

Authors:  Fen Yang; Ying Chang; Lu Yang; Zhijie Jia; Jiewei Liu; Yan Wang
Journal:  Int Ophthalmol       Date:  2022-07-22       Impact factor: 2.029

3.  Improving Tolerance and Compliance with Topical Immunomodulators Using Micro-Emulsion Lipid Layer Artificial Tears.

Authors:  Alice T Epitropoulos; Anthony Therattil; Laura M Periman; Eric D Rosenberg
Journal:  Clin Ophthalmol       Date:  2020-07-06

4.  Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator.

Authors:  Kjell G Gundersen; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2016-11-03

5.  Detailed corneal and genetic characteristics of a pediatric patient with macular corneal dystrophy - case report.

Authors:  Anna Nowińska; Edyta Chlasta-Twardzik; Michał Dembski; Ewa Wróblewska-Czajka; Klaudia Ulfik-Dembska; Edward Wylęgała
Journal:  BMC Ophthalmol       Date:  2021-07-23       Impact factor: 2.209

6.  Clinical Outcomes After Femtosecond Laser-Assisted Arcuate Corneal Incisions versus Manual Incisions.

Authors:  Clayton Blehm; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2021-06-23

7.  Impact of tear optics on the repeatability of Pentacam AXL wave and iTrace in measuring anterior segment parameters and aberrations.

Authors:  Gairik Kundu; Rohit Shetty; Pooja Khamar; Sneha Gupta; Ritika Mullick; Vaitheeswaran L Ganesan; Sharon D'Souza
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

8.  Effect of Oral Re-esterified Omega-3 Nutritional Supplementation on Dry Eyes.

Authors:  Alice T Epitropoulos; Eric D Donnenfeld; Zubin A Shah; Edward J Holland; Michael Gross; William J Faulkner; Cynthia Matossian; Stephen S Lane; Melissa Toyos; Frank A Bucci; Henry D Perry
Journal:  Cornea       Date:  2016-09       Impact factor: 2.651

9.  Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

Authors:  Aysun Şanal Doğan; Canan Gürdal; Mehmet Talay Köylü
Journal:  Turk J Ophthalmol       Date:  2018-04-25

10.  Management of Cataract in Patients with Irregular Astigmatism with Regular Central Component by Phacoemulsification Combined with Toric Intraocular Lens Implantation.

Authors:  Yi Gao; Zi Ye; Wenqian Chen; Jinglan Li; Xinlin Yan; Zhaohui Li
Journal:  J Ophthalmol       Date:  2020-04-30       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.