Literature DB >> 26431473

Integrated photoacoustic and diffuse optical tomography system for imaging of human finger joints in vivo.

Lei Xi, Huabei Jiang.   

Abstract

In this study, we developed a dual-modality tomographic system that integrated photoacoustic imaging (PAI) and diffuse optical tomography (DOT) into a single platform for imaging human finger joints with fine structures and associated optical properties. In PAI, spherical focused transducers were utilized to collect acoustic signals, and the concept of virtual detector was applied in a conventional back-projection algorithm to improve the image quality. A finite-element based reconstruction algorithm was employed to quantitatively recover optical property distribution in the objects for DOT. The phantom results indicate that PAI has a maximum lateral resolution of 70 µm in resolving structures of targets. DOT was able to recover both optical absorption and reduced scattering coefficients of targets accurately. To validate the potential of this system in clinical diagnosis of joint diseases, the distal interphalangeal (DIP) joints of 4 healthy female volunteers were imaged. We successfully obtained high-resolution images of the phalanx and the surrounding soft tissue via PAI, and recovered both optical absorption and reduced scattering coefficients of phalanx using DOT. The in vivo results suggest that this dual-modality system has the potential for the early diagnosis of joint diseases such as osteoarthritis (OA) and rheumatoid arthritis (RA). Integrated PAI/DOT imaging interface (top) and typical reconstruction of structures and associated optical properties of a female finger joint via PAI and DOT (bottom).
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  diffuse optical tomography; photoacoustic imaging; quantitative reconstruction algorithm

Mesh:

Year:  2015        PMID: 26431473     DOI: 10.1002/jbio.201500197

Source DB:  PubMed          Journal:  J Biophotonics        ISSN: 1864-063X            Impact factor:   3.207


  4 in total

1.  Non-contact dynamic diffuse optical tomography imaging system for evaluating lower extremity vasculature.

Authors:  J W Hoi; H K Kim; C J Fong; L Zweck; A H Hielscher
Journal:  Biomed Opt Express       Date:  2018-10-19       Impact factor: 3.732

2.  Intracerebral haemorrhage-induced injury progression assessed by cross-sectional photoacoustic tomography.

Authors:  Jinge Yang; Dan Wu; Guang Zhang; Yuan Zhao; Max Jiang; Xin Yang; Qiwen Xu; Huabei Jiang
Journal:  Biomed Opt Express       Date:  2017-11-29       Impact factor: 3.732

3.  Back-projection algorithm in generalized form for circular-scanning-based photoacoustic tomography with improved tangential resolution.

Authors:  Bo Wang; Tianning Su; Weiran Pang; Ningning Wei; Jiaying Xiao; Kuan Peng
Journal:  Quant Imaging Med Surg       Date:  2019-03

Review 4.  Role of Contrast-enhanced Ultrasound in the Evaluation of Inflammatory Arthritis.

Authors:  Chen-Yang Zhao; Yu-Xin Jiang; Jian-Chu Li; Zhong-Hui Xu; Qing Zhang; Na Su; Meng Yang
Journal:  Chin Med J (Engl)       Date:  2017-07-20       Impact factor: 2.628

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.