Backscatter-difference Measurements of Cancellous Bone Using an Ultrasonic Imaging System.

Brent K Hoffmeister1, Morgan R Smathers2, Catherine J Miller2, Joseph A McPherson2, Cameron R Thurston2, P Luke Spinolo2, Sang-Rok Lee3.   

Abstract

Backscatter-difference measurements may be used to detect changes in bone caused by osteoporosis. The backscatter-difference technique measures the power difference between two portions of an ultrasonic backscatter signal. The goal of this study is to evaluate the feasibility of using an ultrasonic imaging system to perform backscatter-difference measurements of bone. Ultrasonic images and backscatter signals were acquired from 24 specimens of human cancellous bone. The signals were analyzed in the frequency domain to determine the normalized mean backscatter-difference (nMBD) and in the time domain to determine the normalized backscatter amplitude ratio (nBAR). The images were analyzed to determine the normalized pixel value difference (nPVD), which measures the difference in average pixel brightness between regions of interest placed at two different depths in the image. All three parameters were found to increase with bone mineral density. The signal-based parameters, nMBD and nBAR, correlated well with bone mineral density, yielding linear correlation coefficients that ranged from 0.74 to 0.87. The image based parameter, nPVD, performed somewhat less well, yielding correlation coefficients that ranged from 0.42 to 0.81. These results suggest that ultrasonic imaging systems may be used to perform backscatter-difference measurements for the purpose of ultrasonic bone assessment.
© The Author(s) 2015.

Entities:  

Keywords:  backscatter; cancellous bone; osteoporosis; ultrasound

Mesh:

Year:  2015        PMID: 26416839      PMCID: PMC4809788          DOI: 10.1177/0161734615603703

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  21 in total

1.  Dual-frequency ultrasound technique minimizes errors induced by soft tissue in ultrasound bone densitometry.

Authors:  J Karjalainen; J Toyras; T Rikkonen; J S Jurvelin; O Riekkinen
Journal:  Acta Radiol       Date:  2008-11       Impact factor: 1.990

2.  Dual-frequency ultrasound--new pulse-echo technique for bone densitometry.

Authors:  O Riekkinen; M A Hakulinen; J Töyräs; J S Jurvelin
Journal:  Ultrasound Med Biol       Date:  2008-06-04       Impact factor: 2.998

Review 3.  Ultrasonic scattering from cancellous bone: a review.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-07       Impact factor: 2.725

4.  A backscatter difference technique for ultrasonic bone assessment.

Authors:  Brent K Hoffmeister; Anne R Wilson; Matthew J Gilbert; Mark E Sellers
Journal:  J Acoust Soc Am       Date:  2012-12       Impact factor: 1.840

5.  A narrowband pulse-echo technique for in vivo ultrasonic attenuation estimation.

Authors:  J Ophir; R E McWhirt; N F Maklad; P M Jaeger
Journal:  IEEE Trans Biomed Eng       Date:  1985-03       Impact factor: 4.538

6.  Clinical application of an ultrasound attenuation coefficient estimation technique for liver pathology characterization.

Authors:  R Kuc
Journal:  IEEE Trans Biomed Eng       Date:  1980-06       Impact factor: 4.538

7.  Effect of the cortex on ultrasonic backscatter measurements of cancellous bone.

Authors:  Brent K Hoffmeister; Andrew P Holt; Sue C Kaste
Journal:  Phys Med Biol       Date:  2011-09-06       Impact factor: 3.609

8.  In-vivo measurements of ultrasound attenuation in normal or diseased liver.

Authors:  K J Parker; M S Asztely; R M Lerner; E A Schenk; R C Waag
Journal:  Ultrasound Med Biol       Date:  1988       Impact factor: 2.998

9.  Measurements of ultrasonic backscattered spectral centroid shift from spine in vivo: methodology and preliminary results.

Authors:  Brian S Garra; Melanie Locher; Steven Felker; Keith A Wear
Journal:  Ultrasound Med Biol       Date:  2008-08-23       Impact factor: 2.998

10.  Characterization of trabecular bone using the backscattered spectral centroid shift.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-04       Impact factor: 3.267

View more
  4 in total

1.  Ultrasonic backscatter difference measurements of cancellous bone from the human femur: Relation to bone mineral density and microstructure.

Authors:  Brent K Hoffmeister; Ann M Viano; Jinsong Huang; Luke C Fairbanks; Sheldon C Ebron; Joshua T Moore; Jordan P Ankersen; Matthew T Huber; Abel A Diaz
Journal:  J Acoust Soc Am       Date:  2018-06       Impact factor: 1.840

2.  Characterization of a polymer, open-cell rigid foam that simulates the ultrasonic properties of cancellous bone.

Authors:  Brent K Hoffmeister; Matthew T Huber; Ann M Viano; Jinsong Huang
Journal:  J Acoust Soc Am       Date:  2018-02       Impact factor: 1.840

3.  Effect of gate choice on backscatter difference measurements of cancellous bone.

Authors:  Brent K Hoffmeister; Ann M Viano; Luke C Fairbanks; Sheldon C Ebron; Joseph A McPherson; Matthew T Huber
Journal:  J Acoust Soc Am       Date:  2017-08       Impact factor: 1.840

4.  Scattering in Cancellous Bone.

Authors:  Keith Wear
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.