Literature DB >> 26407962

Accuracy of residual apnea-hypopnea index obtained using the continuous positive airway pressure device: application of new version 2.0 scoring rules for respiratory events during sleep.

Doh-Eui Kim1, Young Hwangbo2, Ji Hyun Bae1, Kwang Ik Yang3.   

Abstract

PURPOSE: Continuous positive airway pressure (CPAP) devices can estimate apnea-hypopnea index (AHI) using respiratory event detection algorithms. In 2012, rules for manually scoring respiratory events during sleep were updated to version 2.0. The purpose of the present study was to compare residual AHI determined using the Sleepstyle HC608 CPAP device (HC) with those determined by the new manual scoring (NM) rules during CPAP titration in patients with obstructive sleep apnea (OSA).
METHODS: Fifty-seven patients underwent CPAP titration with HC. Correlations were assessed between AHI determined by NM and HC. The AHI, the apnea index (AI), and the hypopnea index (HI) were evaluated separately.
RESULTS: The mean AHI as assessed using diagnostic polysomnography (PSG) was 53.9 ± 22.4. During CPAP titration, respiratory events were effectively suppressed (HC-AHI, 4.2 ± 6.0; NM-AHI, 6.0 ± 5.8). Lower HI and AHI were obtained using HC compared to NM (HC-HI, 2.9 ± 3.6 and NM-HI, 5.2 ± 4.2, p < 0.001; HC-AHI, 4.2 ± 6.0 and NM-AHI, 6.0 ± 5.8, p < 0.001). Additionally, HC reported higher AI compared to NM (HC-AI, 1.3 ± 2.8; NM-AI, 0.9 ± 2.2, p = 0.002). NM-AI (ß = 1.017, p < 0.001), NM-HI (ß = -0.599, p < 0.001), and NM-arousal index (ß = -0.058, p = 0.042) were associated with greater differences between HC-AHI and NM-AHI in multivariate regression analysis.
CONCLUSIONS: Our findings indicate differences in scoring respiratory events between our CPAP device and new version 2.0 manual scoring and suggest that residual AHI values should be carefully interpreted.

Entities:  

Keywords:  Continuous positive airway pressure; Obstructive sleep apnea; Residual apnea-hypopnea index; Smart card

Mesh:

Year:  2015        PMID: 26407962     DOI: 10.1007/s11325-015-1257-0

Source DB:  PubMed          Journal:  Sleep Breath        ISSN: 1520-9512            Impact factor:   2.816


  14 in total

Review 1.  Sleep apnea and cardiovascular disease.

Authors:  R S Leung; T D Bradley
Journal:  Am J Respir Crit Care Med       Date:  2001-12-15       Impact factor: 21.405

2.  Reliability and validity testing of automated scoring in obstructive sleep apnea diagnosis with the Embletta X100.

Authors:  Do Y Park; Hyun J Kim; Chang-Hoon Kim; Yoo S Kim; Ji H Choi; Sang Y Hong; Jin J Jung; Kang I Lee; Han S Lee
Journal:  Laryngoscope       Date:  2014-08-14       Impact factor: 3.325

3.  Sleep-disordered breathing and cardiovascular disease: cross-sectional results of the Sleep Heart Health Study.

Authors:  E Shahar; C W Whitney; S Redline; E T Lee; A B Newman; F J Nieto; G T O'Connor; L L Boland; J E Schwartz; J M Samet
Journal:  Am J Respir Crit Care Med       Date:  2001-01       Impact factor: 21.405

4.  Evaluation of the apnea-hypopnea index determined by the S8 auto-CPAP, a continuous positive airway pressure device, in patients with obstructive sleep apnea-hypopnea syndrome.

Authors:  Kanako Ueno; Takatoshi Kasai; Gregory Brewer; Hisashi Takaya; Ken-ichi Maeno; Satoshi Kasagi; Fusae Kawana; Sugao Ishiwata; Koji Narui
Journal:  J Clin Sleep Med       Date:  2010-04-15       Impact factor: 4.062

5.  Comparison between the apnea-hypopnea indices determined by the REMstar Auto M series and those determined by standard in-laboratory polysomnography in patients with obstructive sleep apnea.

Authors:  Yukiko Ikeda; Takatoshi Kasai; Fusae Kawana; Satoshi Kasagi; Hisashi Takaya; Sugao Ishiwata; Koji Narui
Journal:  Intern Med       Date:  2012-10-15       Impact factor: 1.271

6.  Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography.

Authors:  Bharati Prasad; David W Carley; James J Herdegen
Journal:  Sleep Breath       Date:  2009-10-14       Impact factor: 2.816

7.  Comparison of polysomnography with ResCare Autoset in the diagnosis of the sleep apnoea/hypopnoea syndrome.

Authors:  P A Bradley; I L Mortimore; N J Douglas
Journal:  Thorax       Date:  1995-11       Impact factor: 9.139

8.  Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea.

Authors:  Clete A Kushida; Alejandro Chediak; Richard B Berry; Lee K Brown; David Gozal; Conrad Iber; Sairam Parthasarathy; Stuart F Quan; James A Rowley
Journal:  J Clin Sleep Med       Date:  2008-04-15       Impact factor: 4.062

9.  Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders.

Authors:  Clete A Kushida; Michael R Littner; Max Hirshkowitz; Timothy I Morgenthaler; Cathy A Alessi; Dennis Bailey; Brian Boehlecke; Terry M Brown; Jack Coleman; Leah Friedman; Sheldon Kapen; Vishesh K Kapur; Milton Kramer; Teofilo Lee-Chiong; Judith Owens; Jeffrey P Pancer; Todd J Swick; Merrill S Wise
Journal:  Sleep       Date:  2006-03       Impact factor: 5.849

10.  Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

Authors:  Timothy I Morgenthaler; R Nisha Aurora; Terry Brown; Rochelle Zak; Cathy Alessi; Brian Boehlecke; Andrew L Chesson; Leah Friedman; Vishesh Kapur; Rama Maganti; Judith Owens; Jeffrey Pancer; Todd J Swick
Journal:  Sleep       Date:  2008-01       Impact factor: 5.849

View more
  3 in total

1.  A longitudinal study of the accuracy of positive airway pressure therapy machine-detected apnea-hypopnea events.

Authors:  Yue-Nan Ni; Robert Joseph Thomas
Journal:  J Clin Sleep Med       Date:  2022-04-01       Impact factor: 4.062

2.  Interpreting CPAP device respiratory indices in children.

Authors:  Rebecca Mihai; Kirsten Ellis; Margot J Davey; Gillian M Nixon
Journal:  J Clin Sleep Med       Date:  2020-10-15       Impact factor: 4.062

3.  Quantitative Changes in Muscular and Capillary Oxygen Desaturation Measured by Optical Sensors during Continuous Positive Airway Pressure Titration for Obstructive Sleep Apnea.

Authors:  Zhongxing Zhang; Ming Qi; Gordana Hügli; Ramin Khatami
Journal:  Biosensors (Basel)       Date:  2021-12-21
  3 in total