Literature DB >> 26394637

CORR Insights(®): implant design variations in reverse total shoulder arthroplasty influence the required deltoid force and resultant joint load.

Robert Z Tashjian1.   

Abstract

Mesh:

Year:  2015        PMID: 26394637      PMCID: PMC4626494          DOI: 10.1007/s11999-015-4551-z

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


× No keyword cloud information.
  6 in total

1.  Effect of lateral offset center of rotation in reverse total shoulder arthroplasty: a biomechanical study.

Authors:  Heath B Henninger; Alexej Barg; Andrew E Anderson; Kent N Bachus; Robert T Burks; Robert Z Tashjian
Journal:  J Shoulder Elbow Surg       Date:  2011-10-29       Impact factor: 3.019

2.  Effect of reverse shoulder design philosophy on muscle moment arms.

Authors:  Matthew A Hamilton; Phong Diep; Chris Roche; Pierre Henri Flurin; Thomas W Wright; Joseph D Zuckerman; Howard Routman
Journal:  J Orthop Res       Date:  2015-02-12       Impact factor: 3.494

3.  Impact of inferior glenoid tilt, humeral retroversion, bone grafting, and design parameters on muscle length and deltoid wrapping in reverse shoulder arthroplasty.

Authors:  Christopher P Roche; Phong Diep; Matthew Hamilton; Lynn A Crosby; Pierre-Henri Flurin; Thomas W Wright; Joseph D Zuckerman; Howard D Routman
Journal:  Bull Hosp Jt Dis (2013)       Date:  2013

4.  Effect of prosthesis design on muscle length and moment arms in reverse total shoulder arthroplasty.

Authors:  Matthew A Hamilton; Christopher P Roche; Phong Diep; Pierre-Henri Flurin; Howard D Routman
Journal:  Bull Hosp Jt Dis (2013)       Date:  2013

5.  Reverse total shoulder arthroplasty: a biomechanical evaluation of humeral and glenosphere hardware configuration.

Authors:  Robert Z Tashjian; Robert T Burks; Yue Zhang; Heath B Henninger
Journal:  J Shoulder Elbow Surg       Date:  2014-10-22       Impact factor: 3.019

6.  Reverse prostheses in arthropathies with cuff tear: are survivorship and function maintained over time?

Authors:  Luc Favard; Christophe Levigne; Cécile Nerot; Christian Gerber; Lieven De Wilde; Daniel Mole
Journal:  Clin Orthop Relat Res       Date:  2011-09       Impact factor: 4.176

  6 in total
  1 in total

1.  Does Humeral Component Lateralization in Reverse Shoulder Arthroplasty Affect Rotator Cuff Torque? Evaluation in a Cadaver Model.

Authors:  Kevin Chan; G Daniel G Langohr; Matthew Mahaffy; James A Johnson; George S Athwal
Journal:  Clin Orthop Relat Res       Date:  2017-06-14       Impact factor: 4.176

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.