Literature DB >> 24344621

Impact of inferior glenoid tilt, humeral retroversion, bone grafting, and design parameters on muscle length and deltoid wrapping in reverse shoulder arthroplasty.

Christopher P Roche, Phong Diep, Matthew Hamilton, Lynn A Crosby, Pierre-Henri Flurin, Thomas W Wright, Joseph D Zuckerman, Howard D Routman.   

Abstract

PURPOSE: This study quantifies the ability of humeral retroversion, glenoid tilt, bone graft, and varying prosthesis design parameters to restore anatomic muscle length and deltoid wrapping with reverse shoulder arthroplasty.
METHODS: A computer model simulated abduction and internal and external rotation for a normal shoulder, the RSP reverse shoulder, the Equinoxe reverse shoulder, and the Grammont reverse shoulder when implanted using various implantation methods. The length of eight different muscles and the deltoid wrapping angle were quantified to evaluate the ability of each implantation method and design to restore anatomic muscle tensioning.
RESULTS: Each reverse shoulder shifted the center of rotation medially and inferiorly relative to the normal shoulder and caused a corresponding shift in the position of the humerus. Each reverse shoulder elongated each head of the deltoid and shortened the internal and external rotators relative to the normal shoulder. The surgical techniques and prosthesis designs, which resulted in a more lateral humeral position, were associated with more deltoid wrapping and better tensioning of the anterior and posterior shoulder muscles.
CONCLUSIONS: Muscle tensioning and deltoid wrapping can be substantially altered by surgical implantation meth- ods using the Grammont reverse shoulder. However, the results of this study demonstrate that more anatomic muscle tensioning and improved deltoid wrapping are achieved using alternative prosthesis designs that better restore the lateral position of the humerus.

Entities:  

Mesh:

Year:  2013        PMID: 24344621

Source DB:  PubMed          Journal:  Bull Hosp Jt Dis (2013)        ISSN: 2328-4633


  18 in total

1.  CORR Insights(®): implant design variations in reverse total shoulder arthroplasty influence the required deltoid force and resultant joint load.

Authors:  Robert Z Tashjian
Journal:  Clin Orthop Relat Res       Date:  2015-09-22       Impact factor: 4.176

2.  Radiographic parameters associated with excellent versus poor range of motion outcomes following reverse shoulder arthroplasty.

Authors:  Georges Haidamous; Alexandre Lädermann; Robert U Hartzler; Bradford O Parsons; Evan S Lederman; John M Tokish; Patrick J Denard
Journal:  Shoulder Elbow       Date:  2020-07-09

3.  Risk factors of instability following reverse total shoulder arthroplasty in patients with no history of shoulder surgery.

Authors:  Margaret A Sinkler; Joshua D Dolan; Drew Henderson; Michael J Steflik; Frank D Lewis; Stephen A Parada; Lynn A Crosby
Journal:  J Orthop       Date:  2022-09-29

4.  Grammont versus lateralizing reverse shoulder arthroplasty for proximal humerus fracture: functional and radiographic outcomes.

Authors:  M A Verdano; D Aliani; C Galavotti; C Maroun; E Vaienti; F Ceccarelli
Journal:  Musculoskelet Surg       Date:  2018-10-20

Review 5.  Prosthesis design and placement in reverse total shoulder arthroplasty.

Authors:  David C Ackland; Minoo Patel; David Knox
Journal:  J Orthop Surg Res       Date:  2015-07-02       Impact factor: 2.359

Review 6.  A Critical Review on Prosthetic Features Available for Reversed Total Shoulder Arthroplasty.

Authors:  Bart Middernacht; Alexander Van Tongel; Lieven De Wilde
Journal:  Biomed Res Int       Date:  2016-12-25       Impact factor: 3.411

7.  The influence of preoperative external rotation weakness or stiffness on reverse total shoulder arthroplasty.

Authors:  Brad Carofino; Howard Routman; Chris Roche
Journal:  JSES Int       Date:  2020-05-06

8.  Revision of reversed shoulder arthroplasty: Is a reoperation possible?

Authors:  Stijn Casier; Bart Middernacht; Alexander Van Tongel; Lieven De Wilde
Journal:  Obere Extrem       Date:  2017-03-07

9.  Achilles tendon allograft for an irreparable massive rotator cuff tear with bony deficiency of the greater tuberosity.

Authors:  Alexandre Lädermann; Patrick J Denard; Sophie Abrassart; Adrien J-P Schwitzguébel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-25       Impact factor: 4.342

10.  Humeral bone resorption after reverse shoulder arthroplasty using uncemented stem.

Authors:  Kazuya Inoue; Naoki Suenaga; Naomi Oizumi; Hiroshi Yamaguchi; Naoki Miyoshi; Noboru Taniguchi; Shuzo Morita; Mitsuru Munemoto; Shimpei Kurata; Yasuhito Tanaka
Journal:  JSES Int       Date:  2020-01-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.