Literature DB >> 26390102

Effect of Sensor-Augmented Pump Treatment Versus Multiple Daily Injections on Albuminuria: A 1-Year Randomized Study.

Signe Rosenlund1, Tine Willum Hansen1, Peter Rossing1, Steen Andersen1.   

Abstract

CONTEXT: The effect of glycemic control on persisting albuminuria remains unclear. Insulin delivery and glucose variability may be important.
OBJECTIVE: This study aimed to investigate the effect of 1-year treatment with sensor-augmented insulin pump (SAP) or multiple daily injections (MDIs) on albuminuria. DESIGN, PATIENTS, AND METHODS: This was a randomized controlled open-label parallel trial composed of 60 patients with type 1 diabetes with a history of albuminuria and on stable renin-angiotensin system inhibition, were randomly assigned to SAP or MDI. Urine albumin creatinine ratio (UACR) was measured in three urine samples at all visits. Glucose variability and glomerular filtration rate ((51)Cr-EDTA-GFR) were measured at beginning and study end. Using linear mixed model, change in UACR between groups was analyzed as intention to treat. MAIN OUTCOME MEASURE: Change in UACR was measured.
RESULTS: Fifty-five patients (SAP, n = 26; MDI, n = 29) completed the study. Diabetes duration (mean ± SD, 33 ± 12 y), UACR (geometric mean, 99 mg/g; interquartile range, 37-233 mg/g), (51)Cr-EDTA-GFR (94 ± 22 mL/min/1.73m(2)), glycosylated hemoglobin (HbA1c) (9.0 ± 1.1%), glucose variability (calculated as SD), 4.0 ± 1.0 mmol/l; no-group differences (P ≥ .06 for all). After 1 year, change in UACR was mean, -13%; 95% confidence interval, -39 to 22 with SAP vs mean, 30%; 95% CI, -12 to 92% on MDI treatment (unadjusted P = .051; adjusted for HbA1c, P = .04). HbA1c decreased 1.3 ± 1.0 vs 0.6 ± 1.0% (P = .013), glucose variability decreased 0.9 ± 1.1 vs 0.3 ± 1.0 mmol/L (P = .04), and (51)Cr-EDTA-GFR declined 5.6 ± 9.6 vs 3.4 ± 13 mL/min/1.73m(2) (P = .50) with SAP vs MDI treatment. There were no changes in blood pressure (P ≥ .27).
CONCLUSION: SAP treatment reduced UACR in a randomized controlled trial in type 1 diabetes patients with a history of albuminuria on stable renin-angiotensin system inhibition. Significance was reached after adjustment. SAP treatment reduced HbA1c and glucose variability (calculated as SD).

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26390102     DOI: 10.1210/jc.2015-2839

Source DB:  PubMed          Journal:  J Clin Endocrinol Metab        ISSN: 0021-972X            Impact factor:   5.958


  8 in total

Review 1.  Continuous subcutaneous insulin infusion versus multiple daily injections in individuals with type 1 diabetes: a systematic review and meta-analysis.

Authors:  Khalid Benkhadra; Fares Alahdab; Shrikant U Tamhane; Rozalina G McCoy; Larry J Prokop; Mohammad Hassan Murad
Journal:  Endocrine       Date:  2016-08-01       Impact factor: 3.633

2.  Continuous Subcutaneous Insulin Infusion Initiation Is Associated With Blood Pressure Reduction in Adults With Type 1 Diabetes.

Authors:  Konstantinos Markakis; Tayiba Alam; Pushpa Jinadev; Alyson Chapman; Andrea Urwin; Hood Thabit; Andrew J M Boulton; Martin K Rutter; Lalantha Leelarathna
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

3.  Association of Insulin Pump Therapy vs Insulin Injection Therapy With Severe Hypoglycemia, Ketoacidosis, and Glycemic Control Among Children, Adolescents, and Young Adults With Type 1 Diabetes.

Authors:  Beate Karges; Anke Schwandt; Bettina Heidtmann; Olga Kordonouri; Elisabeth Binder; Ulrike Schierloh; Claudia Boettcher; Thomas Kapellen; Joachim Rosenbauer; Reinhard W Holl
Journal:  JAMA       Date:  2017-10-10       Impact factor: 56.272

4.  Randomized Cross-Over Study Comparing Two Infusion Sets for CSII in Daily Life.

Authors:  Guido Freckmann; Stephan Arndt; Albrecht Fießelmann; Gerhard Klausmann; Kristina Pralle; Thomas Künsting; Bettina Petersen
Journal:  J Diabetes Sci Technol       Date:  2016-09-25

Review 5.  Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

Authors:  Kazuhiro Hanazaki; Masaya Munekage; Hiroyuki Kitagawa; Tomoaki Yatabe; Eri Munekage; Mai Shiga; Hiromichi Maeda; Tsutomu Namikawa
Journal:  J Artif Organs       Date:  2016-05-03       Impact factor: 1.731

6.  Comparing the effectiveness of continuous subcutaneous insulin infusion with multiple daily insulin injection for patients with type 1 diabetes mellitus evaluated by retrospective continuous glucose monitoring: A real-world data analysis.

Authors:  Guo Keyu; Li Jiaqi; Zhang Liyin; Ye Jianan; Fan Li; Ding Zhiyi; Zhou Qin; Li Xia; Yang Lin; Zhou Zhiguang
Journal:  Front Public Health       Date:  2022-08-25

7.  Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2018-02-21

8.  HbA1c variability in adults with type 1 diabetes on continuous subcutaneous insulin infusion (CSII) therapy compared to multiple daily injection (MDI) treatment.

Authors:  Emma S Scott; Rachel T McGrath; Andrzej S Januszewski; Daniel Calandro; Anandwardhan A Hardikar; David N O'Neal; Gregory Fulcher; Alicia J Jenkins
Journal:  BMJ Open       Date:  2019-12-29       Impact factor: 2.692