Literature DB >> 26388687

Pentoxifylline and electromagnetic field improved bone fracture healing in rats.

Yusuf Atalay1, Nedim Gunes2, Mehmet Dervis Guner3, Veysi Akpolat4, Mustafa Salih Celik4, Rezzan Guner2.   

Abstract

BACKGROUND: The aim of this study was to evaluate the effects of a phosphodiesterase inhibitor pentoxifylline (PTX), electromagnetic fields (EMFs), and a mixture of both materials on bone fracture healing in a rat model.
MATERIALS AND METHODS: Eighty male Wistar rats were randomly divided into four groups: Group A, femur fracture model with no treatment; Group B, femur fracture model treated with PTX 50 mg/kg/day intraperitoneal injection; Group C, femur fracture model treated with EMF 1.5±0.2 Mt/50 Hz/6 hours/day; and Group D, femur fracture model treated with PTX 50 mg/kg/day intraperitoneal injection and EMF 1.5±0.2 Mt/50 Hz/6 hours/day.
RESULTS: Bone fracture healing was significantly better in Group B and Group C compared to Group A (P<0.05), but Group D did not show better bone fracture healing than Group A (P>0.05).
CONCLUSION: It can be concluded that both a specific EMF and PTX had a positive effect on bone fracture healing but when used in combination, may not be beneficial.

Entities:  

Keywords:  bones; electromagnetic fields; fracture healing; pentoxifylline; phosphodiesterase inhibitor; rats

Mesh:

Substances:

Year:  2015        PMID: 26388687      PMCID: PMC4571933          DOI: 10.2147/DDDT.S89669

Source DB:  PubMed          Journal:  Drug Des Devel Ther        ISSN: 1177-8881            Impact factor:   4.162


Introduction

Successful treatment of maxillofacial fractures depends on reduction and fixation to restore the normal occlusion, function, and proper alignment of bones,1 and the success of a wide variety of surgical procedures such as repairing jaw fractures, orthognathic surgery, and repairing bone defects also depends on the physiological process of bone fracture healing. Despite progressions in maxillofacial surgery, bone fractures do not always heal successfully.2 Therefore, studies in recent years have researched different factors such as growth factors, the applied force values, drug injections, or electrical stimulation, which could be considered to be of benefit in more successful rapid bone remodeling.3 Pentoxifylline (PTX) is a competitive non-selective phosphodiesterase inhibitor (PDEI),4 which reduces inflammation, and enhances microcirculation, blood flow, and tissue oxygenation.5 In addition, PTX improves red blood cell deformability and decreases the potential for platelet aggregation and thrombus formation.6 In a previous study, daily injections of PTX have been shown to stimulate bone formation and to increase systemic bone mass in mice.7 In another study, Labib and Farid suggested that PTX could be regarded as a valid approach in the management of osseointegration.8 In addition, many studies have demonstrated the positive effects of PTX in healing of mandibular.9,10 The efficacy of PTX in treatment is essentially due to its potential to increase blood flow and tissue oxygenation with its hemorheologic effects.11 Since a vascular response is a prerequisite for successful bone healing physiology,12,13 it was hypothesized that in the current research that PTX might also be beneficial for bone fracture healing. A variety of non-invasive bone fracture treatment techniques have been used for biophysical stimulation to accelerate and finalize bone healing.14 One of these methods is electromagnetic field (EMF) stimulation, a method which has been used in cases of bone fracture healing for over three decades.15–18 Although the US Food and Drug Administration have approved EMF therapy as a safe and effective method for treating osteoporosis and as therapy for bone non-union,19,20 there are still some controversial results.21,22 Despite a long history of clinical use of EMFs and research, there is still poor understanding of the underlying action mechanisms of EMFs and the optimal parameters for usage. However, all researchers have emphasized that in the treatment of various diseases, it is necessary to determine the appropriate frequency and level of EMFs to be able to create gold-standard treatment protocols.23,24 To obtain normal functioning of the bone fracture and its surrounding structures, the swift recovery to normal anatomy after reduction is crucial, and an increasing number of studies are researching this subject.25 The purpose of the current study was to undertake histological evaluations of the effects of PTX as a peripheral vasodilator, EMF therapy as a biophysical stimulator, and a combination of both materials on the repair process of a femur fracture in a rat model.

Materials and methods

Study design

The study included 80 male Wistar albino rats (mean age, 12 weeks; weight 300±20 g) and was conducted at the Health Institution Research Centre, Dicle University, Diyarbakır, Turkey. All animals were acclimatized to laboratory conditions for 2 weeks before beginning the experiments. The animals were individually housed in flexiglass cages in a controlled environment (22°C±2°C; 12-hour light–dark cycle) with free access to drinking water and a diet of standard laboratory rat food pellets. The experimental protocol of the study was approved by the Animal Experiment Ethics Committee of Dicle University. The animals were maintained and used in accordance with the animal welfare act and guidance for the care and use of laboratory animals.26 The rats were randomly divided into four groups: Group A (control group), femur fracture model with no treatment (n=20); Group B (PTX group), femur fracture model treated with PTX (50 mg/kg/day) intraperitoneal injection (n=20); Group C (EMF group), femur fracture model treated with EMF (1.5±0.2 Mt/50 Hz/6 hours/day) (n=20); and Group D (PTX + EMF group), femur fracture model treated with PTX (50 mg/kg/day) intraperitoneal injection and EMF (1.5±0.2 Mt/50 Hz/6 hours/day) (n=20). Group A and Group C received a daily intraperitoneal injection in order to simulate any possible influence of psychical trauma or physical stress on bone healing caused by injection.

Chemicals

PTX (Trental®; 100 mg ampoules) was obtained from Sanofi-Aventis, Bridgewater, NJ, USA; cefazolin sodium (1 g vials) was purchased from Astellas Pharma Inc, Tokyo, Japan; ketamine chlorhydrate (10 mL) was acquired from Pfizer Inc, New York, NY, USA; and xylazine chlorhydrate (25 mL) was procured from Bayer AG, Leverkusen, Germany.

Rat femur fracture model and surgical procedure

Surgical procedures were performed under general anesthesia consisting of a combination of ketamine chlorhydrate (0.08 mL/100 g body weight) and xylazine chlorhydrate 2% (0.04 mL/100 g body weight). In the present study, the open surgery model of experimental fracture healing models was used. In this technique, the fracture is created with a hammer osteotomy, Gigli saw, or electric saw. This technique provides a transverse fracture line and in this respect, is more controlled than closed models.27 However, in a previous study of different gap sizes, the callus geometry, tissue differentiation patterns, and fracture stiffness predicted by the model were similar to experimental observations for every analyzed situation.28 After positioning the right and left legs in flexion, a longitudinal cutaneous, subcutaneous, and periosteal incision was made 20–25 mm in length to reach the medial surface of the left femur. Exposing the medial surface of the femur with blunt dissection, the soft tissue was then retracted. Before making the bone incision, a four-holed microplate was adapted to the bone. After fixing the microplate, a bicortical bone incision was made with a 1 mm diameter fissure and a size 12 stainless steel dental burr (Meisinger, Nuess, Germany) on a low-speed handpiece, under constant sterile saline irrigation starting from the buccal cortical bone. A gap was left between the bone segments up to the thickness of the burr (1 mm) (Figure 1). Then, the rigid stabilization of the fracture segments with the microplate and screws was checked again. Subcutaneous tissue layers were sutured with resorbable sutures, and the skin was sutured with silk. Upon completion of the surgical procedure, each animal received a single dose of 100 mg/kg cefazolin sodium antibiotic by intramuscular injection. Following surgery, ten rats per study group were killed at Day 21 and at Day 30 using high-dose ketamine.
Figure 1

A photographic image of the surgical procedure showing the gap between the bone segments after fixing the microplate.

EMF and PTX administration

Published data on the affirmative efficacy of EMF and PTX in rats are in agreement with the daily doses of 50 Hz29 and 50 mg/kg,30 respectively, that animals received in the present study. To avoid any outside interference to the magnetic field (MF) during the application of the EMF, the experimental mechanism was placed inside an installed Faraday cage. For the EMF to reach the groups without hindrance, flexiglass cages were used. The EMF was produced by a pair of Helmholtz coils with a wrap-around number of 125, with internal diameter of 47 cm, and at distance intervals of 70 cm, placed vertically in a Faraday cage. Two identical Helmholtz coils inside the Faraday cage were attached to two identical power sources producing the same voltage and current (48 V, 40 A). Throughout the application of the EMF to the rats, measurements were regularly taken with a digital teslameter (FW Bell Corporation, Orlando, FL, USA) at 15 different points within the flexiglass cage. As a result of the measurements, the mean peak force was determined as 1.5±0.2 mT. After the pulse generator was switched off, the EMF measured in the cage environment, ie, the background, was found to be 1.5±0.2 mT, 50 Hz frequency and peak duration 1.3 ms. The application of the EMF was started on postoperative Day 1, and was continued once a day every day at 1.5±0.2 mT intensity and at a frequency of 50 Hz for 6 hours. Throughout all the applications, an observer visited the study room regularly each hour, and the procedures were continued without interruption. The application of PTX was started on postoperative Day 1, was applied intraperitoneally at 50 mg/kg/day as a single dose of PTX (Trental® ampoule [100 mg]) once a day every day.

Histopathological evaluations

Bone regeneration and fibrotic healing were evaluated histopathologically. The rat femurs were fixed in 10% formaldehyde solution for 48 hours and were decalcified with 5% nitric acid. The specimens were washed with distilled water, dehydrated with increasing increments of concentrations of ethyl alcohol, cleaned in xylene, and were then embedded in paraffin. Beginning from the center of each specimen, sequential parts were cut parallel to the mid-sagittal defect using a microtome. Transverse sections of 4–5 μm thickness were prepared for each tibia defect and were stained with hematoxylin and eosin. The tissue samples were assessed by a pathologist using a light microscope. The pathologist was blinded to the treatment group that each specimen came from. A 10-point scale31 was used for evaluation of bone healing, where tissue was scored according to the histopathological findings in the healing zone, as follows: 1 point, only fibrous tissue; 2 points, predominantly fibrous tissue; 3 points, equal amounts of fibrous and cartilage tissue; 4 points, predominantly cartilage tissue with little fibrous tissue; 5 points, only cartilage tissue; 6 points, predominantly cartilage tissue with little immature bone; 7 points, equal amounts of cartilage and immature bone tissue; 8 points, predominantly immature bone with little cartilage tissue; 9 points, healing with immature bone; and 10 points, healing with mature bone. Four slides were examined from each fracture. The mean histological score was calculated for each treatment group.

Statistical analysis

The data obtained for all the parameters to be evaluated were transferred to SPSS for Windows, version 15.0 (SPSS Inc, Chicago, IL, USA) program for statistical analysis. For the comparison of paired parameters for independent variables, the Mann–Whitney U-test was used as a two-way nonparametric test. In all tests, a value of P<0.05 was accepted as statistically significant.

Results

None of the rats died in any of the groups during the course of the experiment. No unwanted condition developed in any rat, and none of the rats was excluded from the study. All of the animals tolerated the procedure well and demonstrated good homeostasis and rapid recovery from anesthesia.

Histopathological results

Comparison of histopathological bone fracture healing scores among all groups at Day 21 and Day 30 is shown in Table 1 and Figure 2. In all groups ten of the rats were sacrificed at day 21 and other ten rats were sacrificed at day 30. In the histological examination, a larger increase was observed in the cartilage and bone volumes in the EMF and PTX groups than in the control groups (Figures 3–5). Using pairwise comparisons, there was no statistically significant difference between Group B (PTX) at Day 21 and Day 30 and Group C (EMF) at Day 21 and Day 30 (P>0.05). The level of bone healing in Group B (PTX) and Group C (EMF) was significantly higher than that of Group A (control) at Day 21 (P<0.05). There was also significantly better healing in Group B (PTX) and Group C (EMF) than in Group A (control) at Day 30 (P<0.05).
Table 1

Statistical analysis of bone healing at Day 21 and Day 30

Study groupsGroup AGroup BGroup CGroup D
Day 21 (n=10)6.30±1.0597.20±0.6327.60±1.0755.40±1.265
P-value0.009a,*0.006b,*0.144c
Day 30 (n=10)6.50±0.8437.80±1.3177.80±0.9195.90±1.101
P-value0.038a,*0.011b,*0.160c
P-value0.203d0.250e0.622f

Notes:

Statistically significant between-group difference (P<0.05, Mann–Whitney U-test). Data are shown as mean ± standard deviation.

Group B compared with group A.

Group C compared with group A.

Group D compared with group A.

Group B compared at Day 21 and Day 30.

Group C compared at Day 21 and Day 30.

Group D compared at Day 21 and Day 30.

Figure 2

Comparison of histopathological bone-healing scores among groups according to the Huo scale.

Notes: *Contradictory values; – median value of control 21 group.

Abbreviations: EMF, electromagnetic field; PTX, pentoxifylline; MIX, both EMF and PTX treatment.

Figure 3

Histopathological sample of bone tissue. The sample shows mostly cartilage and a little newly formed, immature bone tissue.

Notes: The sample is stained with hematoxylin and eosin; magnification, 200×.

Figure 4

Histopathological sample of bone tissue. The sample shows mostly immature bone tissue.

Notes: The sample is stained with hematoxylin and eosin; magnification, 200×.

Figure 5

Histopathological sample of bone tissue. The sample is mostly mature bone tissue.

Notes: The sample is stained with hematoxylin and eosin; magnification, 200×.

Discussion

Swift bone fracture healing after traumas and surgical procedures is crucial in order to regain normal functioning of the bone and its surrounding structures.32 There have been an increasing number of studies on this subject.25,32 Although the outcome of various clinical and surgical procedures in bone healing is affected by several factors, which may be patient-, defect-, or surgery-related variables,32 blood flow and circulation play a significant role in the process of bone remodeling and the reparative regeneration of bone tissue.33,34 After the third day of the fracture in our current study, there was a significant rise in local blood flow, which is associated with vascular proliferation in the formation of fracture callus. Such changes in flow are likely to be secondary to locally controlled vasoreactivity of pre-existing vessels, as opposed to that of newly formed angiogenic vessels.34 The present study aimed to evaluate the possible effects of PTX as a PDEI and EMFs on bone fracture healing. The efficacy of PTX and a specific EMF on the bone-healing stage of a femoral fracture model in rats was evaluated through histopathological analyses. PDEIs provides increased blood flow via the nitric oxide (NO) pathway in the process of bone healing.34 NO is a highly reactive free radical involved in inflammation, arthritis, and bone fracture healing. It is known that NO has a regulatory role in blood flow and perfusion pressure to isolate vascular beds in response to appropriate physiological stimuli.35 Therefore, treatment modalities applied to improve the blood circulation may improve the outcomes of bone healing. Thus, the current study focused on the impact of PTX as a peripheral vasodilator on bone fracture healing. The results of this study have shown that PTX had a positive effect on bone fracture healing. Studies that have examined the role of PDEIs involved in vascular response related to bone healing have reported results comparable to the findings of the present investigation. The administration of two PDEIs, tadalafil and vardenafil, have been shown to result in reduced bone mass, evidenced by in vitro cell culture and in vivo animal models,36,37 and the beneficial effects of the PDEI sildenafil on bone healing have been previously shown.34,37 In a study by Aydın et al30 in which the same dose of PTX was applied as in the current study, it was suggested that the hematoma stage of fracture healing, which is the first phase, might be promoted by PTX. At Day 21, it was thought that the anti-inflammatory effects of PTX might have delayed fracture healing.30 However, in the current study, in complete contrast, positive results of bone healing were obtained at Day 21. Despite the numerous studies on the subject, there is insufficient knowledge about the effects of PDEI use on bone healing metabolism. For many years, EMFs have been researched as a stimulation method to enhance bone regeneration in maxillofacial surgery, including dental implants, distraction osteogenesis, and bone grafts.21,38,39 The knowledge from recent studies40,41 has conclusively demonstrated that the contribution of EMFs to the bone healing process is based on stimulating the expression of growth factors, such as vascular endothelial growth factor and bone morphogenetic protein. EMFs also induce angiogenesis, migration, proliferation, and differentiation of stem cells from the surrounding mesenchymal tissues into cartilage and bone-forming cells in an area of injury.40,41 The beneficial effects of the methods of electromagnetic stimulation have been widely documented. Selecting the parameters (intensity, frequency, etc) likely to have maximum benefits in EMF therapy has been especially complicated,42 because EMFs may influence bone healing through a variety of pathways. In addition, EMF therapy has been reported to have benefits in fracture healing,22 and healing of osteotomies,43 pseudoarthrosis,43 osteoporosis, and the deleterious effects of poor bone mineral density.44 Most published studies suggest that EMFs have a positive effect on bone healing,22,43,45–48 while some studies have reported different results.21,49–51 The scientific evidence regarding the efficacy and efficiency of EMFs is still controversial. However, in a study by Fredericks et al38 it was claimed that low-frequency and low-intensity EMFs are powerful in the acceleration and finalization of bone fracture healing. Similarly, in the present study, it was observed that low-frequency and low-intensity EMF (1.5±0.2 mT, 50 Hz) significantly improved fracture healing in rats treated with EMF in the remodeling phase following treatment, compared with the control group. Controversial results regarding the effectiveness of EMFs on bone and other tissues may partly be due to the wide variations in type, frequency, duration, magnetic intensity, stimulation period length, and dose.52 Differences in the results of the studies might also be related to the study design. There are limited data about experimental studies that use the PTX and EMF combination for the treatment of bone fracture healing. In the current study, in all the groups to which combined therapy was applied, negative results were evident in bone fracture healing. These results may have arisen due to the unfavorable effects of MFs on NO metabolites. A study by Okano et al53 demonstrated that MF decreased plasma levels of NO metabolites. From the results of this study, it could be considered that the regulatory role of NO on the blood flow was suppressed by the EMF, and therefore the bone fracture healing was not successful. There are some limitations to this study. A single dose of PTX (50 mg/kg/day) and EMF (1.5±0.2 Mt/50 Hz/6 hours/day) was applied to the rats, and therefore there can be speculation as the effects on bone fracture healing of different dosages. However, due to ethical restrictions, a larger number of animals could not be used. Other limitations were that histopathological results could not be supported by biochemical and radiological findings; the monitoring period was relatively short; and there was no hemodynamic monitoring of the animals during the experiment. There is a need for further studies to clarify the mechanism of the effect of EMFs and PTX on bone remodeling.

Conclusion

It can be concluded that separate application of both PTX as a peripheral vasodilator and a specific EMF as a biophysical stimulator had a positive effect on bone fracture healing, but when used in combination, there may be no benefits. However, the efficacy of both treatments was modest, and the overall bone healing process could not be completely explained.
  50 in total

Review 1.  Electromagnetic fields and magnets. Investigational treatment for musculoskeletal disorders.

Authors:  D H Trock
Journal:  Rheum Dis Clin North Am       Date:  2000-02       Impact factor: 2.670

2.  The preventive effects of pulsed electromagnetic fields on diabetic bone loss in streptozotocin-treated rats.

Authors:  D Jing; J Cai; G Shen; J Huang; F Li; J Li; L Lu; E Luo; Q Xu
Journal:  Osteoporos Int       Date:  2010-10-26       Impact factor: 4.507

3.  Electromagnetic enhancement of a culture of human SAOS-2 osteoblasts seeded onto titanium fiber-mesh scaffolds.

Authors:  Lorenzo Fassina; Enrica Saino; Livia Visai; Giulia Silvani; Maria Gabriella Cusella De Angelis; Giuliano Mazzini; Francesco Benazzo; Giovanni Magenes
Journal:  J Biomed Mater Res A       Date:  2008-12-01       Impact factor: 4.396

4.  Influence of 1800 MHz GSM-like electromagnetic radiation exposure on fracture healing.

Authors:  Ahmet Aslan; Vecihi Kırdemır; Ahmet Kocak; Tolga Atay; Metin Lütfi Baydar; Remzi Arif Özerdemoglu; Nevres Hürriyet Aydogan
Journal:  Arch Med Res       Date:  2014-02-04       Impact factor: 2.235

5.  The influence of ibuprofen on fracture repair: biomechanical, biochemical, histologic, and histomorphometric parameters in rats.

Authors:  M H Huo; N W Troiano; R R Pelker; C M Gundberg; G E Friedlaender
Journal:  J Orthop Res       Date:  1991-05       Impact factor: 3.494

6.  Pulsed electromagnetic fields and low intensity pulsed ultrasound in bone tissue.

Authors:  Leo Massari; Gaetano Caruso; Vincenzo Sollazzo; Stefania Setti
Journal:  Clin Cases Miner Bone Metab       Date:  2009-05

7.  Kinetics of response to long-term treatment combining pentoxifylline and tocopherol in patients with superficial radiation-induced fibrosis.

Authors:  Sylvie Delanian; Raphaël Porcher; Jérémie Rudant; Jean-Louis Lefaix
Journal:  J Clin Oncol       Date:  2005-10-31       Impact factor: 44.544

8.  Sildenafil accelerates fracture healing in mice.

Authors:  Tina Histing; Kerstin Marciniak; Claudia Scheuer; Patric Garcia; Joerg H Holstein; Moritz Klein; Romano Matthys; Tim Pohlemann; Michael D Menger
Journal:  J Orthop Res       Date:  2011-01-18       Impact factor: 3.494

Review 9.  Biophysical stimulation of bone fracture repair, regeneration and remodelling.

Authors:  Edmund Y S Chao; Nozomu Inoue
Journal:  Eur Cell Mater       Date:  2003-12-31       Impact factor: 3.942

10.  Electromagnetic fields do not affect bone micro-architecture in osteoporotic rats.

Authors:  O P van der Jagt; J C van der Linden; J H Waarsing; J A N Verhaar; H Weinans
Journal:  Bone Joint Res       Date:  2014-07       Impact factor: 5.853

View more
  8 in total

Review 1.  Electrical stimulation-based bone fracture treatment, if it works so well why do not more surgeons use it?

Authors:  Mit Balvantray Bhavsar; Zhihua Han; Thomas DeCoster; Liudmila Leppik; Karla Mychellyne Costa Oliveira; John H Barker
Journal:  Eur J Trauma Emerg Surg       Date:  2019-04-06       Impact factor: 3.693

Review 2.  Electrical Stimulation of Acute Fractures: A Narrative Review of Stimulation Protocols and Device Specifications.

Authors:  Peter J Nicksic; D'Andrea T Donnelly; Nishant Verma; Allison J Setiz; Andrew J Shoffstall; Kip A Ludwig; Aaron M Dingle; Samuel O Poore
Journal:  Front Bioeng Biotechnol       Date:  2022-06-02

3.  [Effect of low-frequency pulsed electromagnetic fields on activity of rat calvarial osteoblasts through IGF-1R/NO signaling pathway].

Authors:  Jiale Shao; Zhizhong Li; Jian Zhou; Kai Li; Rong Qin; Keming Chen
Journal:  Zhejiang Da Xue Xue Bao Yi Xue Ban       Date:  2019-04-25

4.  Comparative effects of systemic administration of levofloxacin and cephalexin on fracture healing in rats.

Authors:  Shayan Golestani; Arash Golestaneh; Atousa Aminzadeh Gohari
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2022-04-30

5.  The effects of pentoxifylline adminstration on fracture healing in a postmenopausal osteoporotic rat model.

Authors:  Mohammad Mahdi Vashghani Farahani; Reza Ahadi; Mohammadamin Abdollahifar; Mohammad Bayat
Journal:  Lab Anim Res       Date:  2017-03-27

6.  Extremely low frequency electromagnetic fields promote mesenchymal stem cell migration by increasing intracellular Ca2+ and activating the FAK/Rho GTPases signaling pathways in vitro.

Authors:  Yingchi Zhang; Jiyuan Yan; Haoran Xu; Yong Yang; Wenkai Li; Hua Wu; Chaoxu Liu
Journal:  Stem Cell Res Ther       Date:  2018-05-21       Impact factor: 6.832

7.  Emerging medical applications based on non-ionizing electromagnetic fields from 0 Hz to 10 THz.

Authors:  Mats-Olof Mattsson; Myrtill Simkó
Journal:  Med Devices (Auckl)       Date:  2019-09-12

Review 8.  Electronic Bone Growth Stimulators for Augmentation of Osteogenesis in In Vitro and In Vivo Models: A Narrative Review of Electrical Stimulation Mechanisms and Device Specifications.

Authors:  Peter J Nicksic; D'Andrea T Donnelly; Madison Hesse; Simran Bedi; Nishant Verma; Allison J Seitz; Andrew J Shoffstall; Kip A Ludwig; Aaron M Dingle; Samuel O Poore
Journal:  Front Bioeng Biotechnol       Date:  2022-02-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.