Literature DB >> 26385911

The consistency between measurements of the femoral neck anteversion angle in DDH on three-dimensional CT and MRI.

Cunhua Mao1, Yanchen Liang2, Chengzong Ding2, Lingfei Guo3, Yanbing Wang4, Qingjuan Zeng2, Guangbin Wang5.   

Abstract

BACKGROUND: Three-dimensional computed tomography (3D CT) has been regarded by some investigators as the gold standard for measurements of the femoral neck anteversion angle (FNA) in developmental dysplasia of the hip (DDH), although a simple and reliable imaging method using a non-ionizing technique is needed.
PURPOSE: To determine the consistency between measurements of the FNA in DDH using 3D CT and magnetic resonance imaging (MRI) and to estimate the precision, reliability, and reproducibility of MRI for the measurement of the FNA and assess whether MRI could replace 3D CT.
MATERIAL AND METHODS: 3D CT and MRI were used to measure the FNA in 22 patients, including 18 girls and four boys, with a mean age of 3 years (age range, 1-7 years). All of the measurements were performed independently by two radiologists at different times. This exercise was repeated 2 weeks later by one of the radiologists.
RESULTS: High consistency was found between the MRI and 3D CT measurements (intraclass correlation coefficient [ICC] of 0.906, P < 0.05). The mean inter-observer and intra-observer agreements were high for MRI (ICC = 0.948 and 0.964, respectively, P < 0.05 for both) and for 3D CT (ICC = 0.942 and 0.966, respectively, P < 0.05 for both).
CONCLUSION: Compared with 3D CT, MRI provided a precise, reliable and reproducible method of measuring the FNA in DDH. MRI is recommended as an appropriate technique for measurement of the FNA in DDH, and this approach could replace 3D CT because it delivers no ionizing radiation and offers a better display of soft tissue pathological changes. © The Foundation Acta Radiologica 2015.

Entities:  

Keywords:  Computed tomography (CT); femoral neck anteversion; magnetic resonance imaging (MRI)

Mesh:

Year:  2015        PMID: 26385911     DOI: 10.1177/0284185115603244

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  8 in total

1.  Pre- and postoperative offset and femoral neck version measurements and validation using 3D computed tomography in total hip arthroplasty.

Authors:  Mats Geijer; Sverrir Kiernan; Martin Sundberg; Gunnar Flivik
Journal:  Acta Radiol Open       Date:  2020-10-08

2.  Does 3DMR provide equivalent information as 3DCT for the pre-operative evaluation of adult Hip pain conditions of femoroacetabular impingement and Hip dysplasia?

Authors:  Kevin Yan; Yin Xi; Chayanit Sasiponganan; Joseph Zerr; Joel E Wells; Avneesh Chhabra
Journal:  Br J Radiol       Date:  2018-08-07       Impact factor: 3.039

3.  Measurement of operative femoral anteversion during cementless total hip arthroplasty and influencing factors for using neck-adjustable femoral stem.

Authors:  Jingyang Sun; Bohan Zhang; Lei Geng; Qingyuan Zheng; Juncheng Li; Wenzhe Cao; Ming Ni; Guoqiang Zhang
Journal:  J Orthop Surg Res       Date:  2021-05-31       Impact factor: 2.359

4.  The radiological research for pelvis asymmetry of unilateral developmental dysplasia of the hip in adult.

Authors:  Ya-Min Li; Jue-Hong Li; Bin Li; Jia-Xing Wang; Yun-Su Chen
Journal:  Saudi Med J       Date:  2016-12       Impact factor: 1.484

5.  Application of three-dimensional reconstruction to improve the preoperative measurement accuracy and applicability of femoral neck torsion angle.

Authors:  Qing Han; Aobo Zhang; Chenyu Wang; Kerong Yang; Jincheng Wang
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

6.  Geometrical restoration during total hip arthroplasty is related to change in gait pattern - a study based on computed tomography and three-dimensional gait analysis.

Authors:  A-C Esbjörnsson; S Kiernan; L Mattsson; G Flivik
Journal:  BMC Musculoskelet Disord       Date:  2021-04-20       Impact factor: 2.362

7.  Coronal and sagittal spinopelvic alignment in the patients with unilateral developmental dysplasia of the hip: a prospective study.

Authors:  Guangyang Zhang; Mufan Li; Hang Qian; Xu Wang; Xiaoqian Dang; Ruiyu Liu
Journal:  Eur J Med Res       Date:  2022-08-27       Impact factor: 4.981

Review 8.  Magnetic Resonance Imaging Versus Computed Tomography for Three-Dimensional Bone Imaging of Musculoskeletal Pathologies: A Review.

Authors:  Mateusz C Florkow; Koen Willemsen; Vasco V Mascarenhas; Edwin H G Oei; Marijn van Stralen; Peter R Seevinck
Journal:  J Magn Reson Imaging       Date:  2022-01-19       Impact factor: 5.119

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.