Literature DB >> 26371854

Biomechanical response to ankle-foot orthosis stiffness during running.

Elizabeth Russell Esposito1, Harmony S Choi2, Johnny G Owens2, Ryan V Blanck2, Jason M Wilken2.   

Abstract

BACKGROUND: The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is an ankle-foot orthosis developed to address the high rates of delayed amputation in the military. Its use has enabled many wounded Service Members to run again. During running, stiffness is thought to influence an orthosis' energy storage and return mechanical properties. This study examined the effect of orthosis stiffness on running biomechanics in patients with lower limb impairments who had undergone unilateral limb salvage.
METHODS: Ten patients with lower limb impairments underwent gait analysis at a self-selected running velocity. 1. Nominal (clinically-prescribed), 2. Stiff (20% stiffer than nominal), and 3. Compliant (20% less stiff than nominal) ankle-foot orthosis stiffnesses were tested.
FINDINGS: Ankle joint stiffness was greatest in the stiffest strut and lowest in the compliant strut, however ankle mechanical work remained unchanged. Speed, stride length, cycle time, joint angles, moments, powers, and ground reaction forces were not significantly different among stiffness conditions. Ankle joint kinematics and ankle, knee and hip kinetics were different between limbs. Ankle power, in particular, was lower in the injured limb.
INTERPRETATION: Ankle-foot orthosis stiffness affected ankle joint stiffness but did not influence other biomechanical parameters of running in individuals with unilateral limb salvage. Foot strike asymmetries may have influenced the kinetics of running. Therefore, a range of stiffness may be clinically appropriate when prescribing ankle-foot orthoses for active individuals with limb salvage. Published by Elsevier Ltd.

Entities:  

Keywords:  IDEO; Joint stiffness; Kinematics; Kinetics; Limb salvage; Mechanical work; Military

Mesh:

Year:  2015        PMID: 26371854     DOI: 10.1016/j.clinbiomech.2015.08.014

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  5 in total

Review 1.  How New Technology Is Improving Physical Therapy.

Authors:  Johnny G Owens; Michelle R Rauzi; Andrew Kittelson; Jeremy Graber; Michael J Bade; Julia Johnson; Dustin Nabhan
Journal:  Curr Rev Musculoskelet Med       Date:  2020-04

2.  Step time asymmetry increases metabolic energy expenditure during running.

Authors:  Owen N Beck; Eric N Azua; Alena M Grabowski
Journal:  Eur J Appl Physiol       Date:  2018-07-19       Impact factor: 3.078

Review 3.  Impact of Traumatic Lower Extremity Injuries Beyond Acute Care: Movement-Based Considerations for Resultant Longer Term Secondary Health Conditions.

Authors:  Courtney M Butowicz; Christopher L Dearth; Brad D Hendershot
Journal:  Adv Wound Care (New Rochelle)       Date:  2017-08-01       Impact factor: 4.730

4.  Characterizing the Mechanical Stiffness of Passive-Dynamic Ankle-Foot Orthosis Struts.

Authors:  Kara R Ashcraft; Alena M Grabowski
Journal:  Front Rehabil Sci       Date:  2022-04-15

5.  Multiplanar Stiffness of Commercial Carbon Composite Ankle-Foot Orthoses.

Authors:  Benjamin R Shuman; Elizabeth Russell Esposito
Journal:  J Biomech Eng       Date:  2022-01-01       Impact factor: 2.097

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.