| Literature DB >> 26371025 |
Rossella Sacchetti1, Giovanna De Luca2, Emilia Guberti3, Franca Zanetti4.
Abstract
Municipal tapEntities:
Keywords: drinking water; healthcare facilities for the elderly; mineral content of drinking water; opportunistic pathogens; point-of-use devices
Mesh:
Substances:
Year: 2015 PMID: 26371025 PMCID: PMC4586667 DOI: 10.3390/ijerph120911163
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Description of some characteristics of the devices in the residential healthcare facilities for the elderly.
| Healthcare Facilities for the Elderly | Kind of Devices | Number of Devices | Number of Individuals Served | Age of Devices (in Months) | |
|---|---|---|---|---|---|
| 1 | C.M. | MWD | 4 | 102 | 54 |
| 2 | L.U. | MWD | 3 | 58 | 36, 36, 13 |
| 3 | S.N. | MWD | 2 | 25 | 12, 8 |
| 4 | M. | MWD | 1 | 20 | 20 |
| 5 | V.C. | MWD | 1 | 22 | 120 |
| 6 | G. | MWD | 1 | 10 | 8 |
| 7 | A. | MWD | 2 | 50 | 29 |
| 8 | F. | MWD | 1 | 31 | 101 |
| 9 | S.G. | MWD | 1 | 22 | 41 |
| 10 | M.T. | MWD | 1 | 15 | 10 |
| 11 | R.M. | MWD | 1 | 18 | 45 |
| 12 | B. | MWD | 2 | 32 | 41, 50 |
| 13 | V.O. | ROWD | 1 | 47 | 119 |
| 14 | S. | ROWD | 4 | 82 | 108 |
| 15 | P. | ROWD | 5 | 45 | 12 |
| 16 | R.A. | ROWD | 3 | 100 | 98 |
| 17 | R. | ROWD | 1 | 21 | 98 |
| 18 | V.F. | ROWD | 1 | 20 | 54 |
| 19 | S.B. | ROWD | 3 | 60 | 41, 91, 91 |
MWD = microfiltered water dispenser; ROWD = reverse osmosis water dispenser.
Bacteriological parameters determinated in water samples.
| Bacteriological Parameters | Microbial Criteria for Unbottled Water (Italian Regulation for Drinking Water) |
|---|---|
| 0/100 mL | |
| Enterococci (ENT) | 0/100 mL |
| Total coliforms (TC) | 0/100 mL |
| Heterotrophic plate count (HPC) 22 °C | “no abnormal change” |
| Heterotrophic plate count (HPC) 37 °C * | |
| 0/250 mL | |
| Coagulase-negative staphylococci (CoNS) ** |
* The determination of this parameter is not required for unbottled drinking water by the Italian regulation. ** The determination of these parameters is not required by the Italian regulation for drinking water; NF, non -fermentative.
Mean values and standard deviation of HPCs.
| 22 °C HPC (Log cfu/mL) | 37 °C HPC (Log cfu/mL) | |||
|---|---|---|---|---|
| Mean | SD | Mean | SD | |
| MWDs | ||||
| municipal tap water | 0.53 | 0.48 | 0.95 | 0.53 |
| still unchilled water | 0.91 | 0.54 | 1.57 | 0.54 |
| still chilled water | 0.71 | 0.51 | 1.37 | 0.50 |
| ROWDs | ||||
| municipal tap water | 0.42 | 0.48 | 0.74 | 0.32 |
| still unchilled water | 1.45 | 0.46 | 1.58 | 0.52 |
| still chilled water | 1.44 | 0.50 | 1.32 | 0.59 |
Figure 1Average log increases (bars showing the 95% confidence intervals) of the HPCs. M = municipal tap water; SU = still unchilled water; SC = still chilled water.
Prevalence of NF-GNB and staphylococci species and the range of isolates.
| NF-GNB | Staphylococci (SA + CoNS) | |||||
|---|---|---|---|---|---|---|
| Species | Number of Positive Samples | Range (cfu/250 mL) | Species | Number of Positive Samples | Range (cfu/250 mL) | |
| M | 2 | 1–2. | 1 | 1 | ||
| 1 | 2 | 1 | 1 | |||
| 1 | 4 | 1 | 1 | |||
| 1 | 50 | 6 | 1–1. | |||
| 1 | 2 | 1 | 2 | |||
| SU | 5 | 19–550 | 1 | 1 | ||
| 1 | 24 | 1 | 1 | |||
| 2 | 5–7. | 1 | 1 | |||
| 1 | 1 | 1 | 1 | |||
| 2 | 2–28. | 2 | 1–1. | |||
| 1 | 9 | |||||
| SC | 7 | 1–573 | 2 | 1–1. | ||
| 1 | 22 | 1 | 1 | |||
| 1 | 64 | 1 | 2 | |||
| 2 | 10–1350 | |||||
| M | 2 | 1–19. | 1 | 2 | ||
| 1 | 633 | |||||
| 1 | 4 | |||||
| 1 | 850 | |||||
| 1 | 1 | |||||
| SU | 1 | 5 | ||||
| 1 | 2 | |||||
| SC | 3 | 4–10. | 2 | 1–2. | ||
| 4 | 1–298 | 1 | 1 | |||
| 1 | 2 | 2 | 1–3. | |||
| 1 | 16 | 1 | 34 | |||
M = municipal tap water; SU = still unchilled water; SC = still chilled water.
Mean values and standard deviation of physical-chemical parameters.
| MWDs | ROWDs | |||
|---|---|---|---|---|
| mean | SD | Mean | SD | |
| Water temperature (°C) | ||||
| municipal tap water | 17.7 | 3.8 | 15.0 | 4.8 |
| still unchilled water | 21.8 | 4.0 | 17.8 | 3.5 |
| still chilled water | 7.9 | 3.9 | 8.2 | 2.6 |
| Residual chlorine (mg/L) | ||||
| municipal tap water | 0.14 | 0.11 | 0.22 | 0.10 |
| still unchilled water | 0.07 | 0.07 | 0.10 | 0.10 |
| still chilled water | 0.06 | 0.06 | 0.10 | 0.10 |
| pH value | ||||
| municipal tap water | 7.42 | 0.33 | 8.07 | 0.17 |
| still unchilled water | 7.40 | 0.27 | 6.87 | 0.44 |
| still chilled water | 7.42 | 0.27 | 6.83 | 0.42 |
| Conductivity (mS/cm) | ||||
| municipal tap water | 600 | 157 | 493 | 52 |
| still unchilled water | 602 | 153 | 69 | 63 |
| still chilled water | 597 | 150 | 67 | 62 |
| Calcium (mg/L) | ||||
| municipal tap water | 93.0 | 28.1 | 71.9 | 7.5 |
| still unchilled water | 90.8 | 26.7 | 7.0 | 8.9 |
| still chilled water | 92.4 | 30.8 | 6.1 | 7.2 |
| Sodium (mg/L) | ||||
| municipal tap water | 26.6 | 9.0 | 20.4 | 4.4 |
| still unchilled water | 26.2 | 11.5 | 4.0 | 3.4 |
| still chilled water | 25.5 | 8.2 | 3.8 | 3.7 |
| Total hardness (°F) | ||||
| municipal tap water | 29.1 | 8.9 | 23.5 | 2.9 |
| still unchilled water | 28.8 | 8.6 | 2.3 | 3.0 |
| still chilled water | 29.7 | 10.3 | 2.4 | 2.7 |
| Total dissolved solids at 180 °C (mg/L) | ||||
| municipal tap water | 406 | 115 | 311 | 45 |
| still unchilled water | 409 | 114 | 43 | 38 |
| still chilled water | 404 | 111 | 46 | 36 |