Literature DB >> 23838062

Microbial quality of drinking water from microfiltered water dispensers.

R Sacchetti1, G De Luca2, A Dormi2, E Guberti3, F Zanetti2.   

Abstract

A comparison was made between the microbial quality of drinking water obtained from Microfiltered Water Dispensers (MWDs) and that of municipal tap water. A total of 233 water samples were analyzed. Escherichia coli (EC), enterococci (ENT), total coliforms (TC), Staphylococcus aureus, Pseudomonas aeruginosa and heterotrophic plate count (HPC) at 22 °C and 37 °C were enumerated. In addition, information was collected about the principal structural and functional characteristics of each MWD in order to study the various factors that might influence the microbial quality of the water. EC and ENT were not detected in any of the samples. TC were never detected in the tap water but were found in 5 samples taken from 5 different MWDs. S. aureus was found in a single sample of microfiltered water. P. aeruginosa was found more frequently and at higher concentrations in the samples collected from MWDs. The mean HPCs at 22 °C and 37 °C were significantly higher in microfiltered water samples compared to those of the tap water. In conclusion, the use of MWDs may increase the number of bacteria originally present in tap water. It is therefore important to monitor the quality of the dispensed water over time, especially if it is destined for vulnerable users.
Copyright © 2013 Elsevier GmbH. All rights reserved.

Entities:  

Keywords:  Drinking water; Heterotrophic plate count; P. aeruginosa; Water dispenser

Mesh:

Substances:

Year:  2013        PMID: 23838062     DOI: 10.1016/j.ijheh.2013.06.002

Source DB:  PubMed          Journal:  Int J Hyg Environ Health        ISSN: 1438-4639            Impact factor:   5.840


  8 in total

1.  A comparative study of microbial contamination between public institutional and private residential bottled water dispensers.

Authors:  Lucy Semerjian; Mariyam M Ibrahim; Bakhita M Alkhateri
Journal:  Environ Monit Assess       Date:  2020-04-02       Impact factor: 2.513

2.  Bacteriological Quality of Drinking Water and Hygienic Assessment of Water Cooler Dispensers in Higher Education Institution.

Authors:  Nopadol Precha; Chayada Rattanaphan; Tanyaporn Galiga; Presert Makkaew; Nutcha Narom; Siriuma Jawjit
Journal:  Int J Prev Med       Date:  2022-04-27

3.  Assessment of Drinking Water Quality from Bottled Water Coolers.

Authors:  Marzieh Farhadkhani; Mahnaz Nikaeen; Behrouz Akbari Adergani; Maryam Hatamzadeh; Bibi Fatemeh Nabavi; Akbar Hassanzadeh
Journal:  Iran J Public Health       Date:  2014-05       Impact factor: 1.429

4.  Quality of Drinking Water Treated at Point of Use in Residential Healthcare Facilities for the Elderly.

Authors:  Rossella Sacchetti; Giovanna De Luca; Emilia Guberti; Franca Zanetti
Journal:  Int J Environ Res Public Health       Date:  2015-09-09       Impact factor: 3.390

5.  Qualitative and health-related evaluation of point-of-use water treatment equipment performance in three cities of Iran.

Authors:  Salimeh Rezaeinia; Simin Nasseri; Masoud Binesh; Farid Ghalambor Dezfuli; Safieh Abdolkhani; Mitra Gholami; Neamat Jaafarzadeh
Journal:  J Environ Health Sci Eng       Date:  2018-09-19

6.  Drinking Water Source and Intake Are Associated with Distinct Gut Microbiota Signatures in US and UK Populations.

Authors:  Tiphaine Vanhaecke; Oriane Bretin; Marion Poirel; Julien Tap
Journal:  J Nutr       Date:  2022-01-11       Impact factor: 4.798

7.  Isolation, identification and reviewing the health effect of HPC bacteria in household point-of-use (PoU) water treatment devices: a case study, Ahvaz, Iran.

Authors:  Nastaran Talepour; Mahdi Hadi; Simin Nasseri; Neamat Jaafarzadeh Haghighi Fard; Alireza Mesdaghinia; Saeedeh Hemmati Borji
Journal:  J Environ Health Sci Eng       Date:  2021-02-16

8.  Infant diet and maternal gestational weight gain predict early metabolic maturation of gut microbiomes.

Authors:  Aimee M Baumann-Dudenhoeffer; Alaric W D'Souza; Phillip I Tarr; Barbara B Warner; Gautam Dantas
Journal:  Nat Med       Date:  2018-10-29       Impact factor: 53.440

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.