Literature DB >> 26368884

Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Yuting Lin, Farouk Nouizi, Tiffany C Kwong, Gultekin Gulsen.   

Abstract

Conventional fluorescence tomography (FT) can recover the distribution of fluorescent agents within a highly scattering medium. However, poor spatial resolution remains its foremost limitation. Previously, we introduced a new fluorescence imaging technique termed "temperature-modulated fluorescence tomography" (TM-FT), which provides high-resolution images of fluorophore distribution. TM-FT is a multimodality technique that combines fluorescence imaging with focused ultrasound to locate thermo-sensitive fluorescence probes using a priori spatial information to drastically improve the resolution of conventional FT. In this paper, we present an extensive simulation study to evaluate the performance of the TM-FT technique on complex phantoms with multiple fluorescent targets of various sizes located at different depths. In addition, the performance of the TM-FT is tested in the presence of background fluorescence. The results obtained using our new method are systematically compared with those obtained with the conventional FT. Overall, TM-FT provides higher resolution and superior quantitative accuracy, making it an ideal candidate for in vivo preclinical and clinical imaging. For example, a 4 mm diameter inclusion positioned in the middle of a synthetic slab geometry phantom (D:40  mm×W:100  mm) is recovered as an elongated object in the conventional FT (x=4.5  mm; y=10.4  mm), while TM-FT recovers it successfully in both directions (x=3.8  mm; y=4.6  mm). As a result, the quantitative accuracy of the TM-FT is superior because it recovers the concentration of the agent with a 22% error, which is in contrast with the 83% error of the conventional FT.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26368884      PMCID: PMC4896397          DOI: 10.1364/AO.54.007612

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  40 in total

Review 1.  A multi-view time-domain non-contact diffuse optical tomography scanner with dual wavelength detection for intrinsic and fluorescence small animal imaging.

Authors:  Eric Lapointe; Julien Pichette; Yves Bérubé-Lauzière
Journal:  Rev Sci Instrum       Date:  2012-06       Impact factor: 1.523

2.  Ultrasound-modulated fluorescence from rhodamine B aqueous solution.

Authors:  Baohong Yuan; Yuan Liu
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

3.  Simultaneous fluorescence yield and lifetime tomography from time-resolved transmittances of small-animal-sized phantom.

Authors:  Feng Gao; Jiao Li; Limin Zhang; Patrick Poulet; Huijuan Zhao; Yukio Yamada
Journal:  Appl Opt       Date:  2010-06-01       Impact factor: 1.980

Review 4.  Applications of thermo-reversible pluronic F-127 gels in pharmaceutical formulations.

Authors:  J J Escobar-Chávez; M López-Cervantes; A Naïk; Y N Kalia; D Quintanar-Guerrero; A Ganem-Quintanar
Journal:  J Pharm Pharm Sci       Date:  2006       Impact factor: 2.327

5.  Near infrared dyes as lifetime solvatochromic probes for micropolarity measurements of biological systems.

Authors:  Mikhail Y Berezin; Hyeran Lee; Walter Akers; Samuel Achilefu
Journal:  Biophys J       Date:  2007-06-15       Impact factor: 4.033

6.  A time domain fluorescence tomography system for small animal imaging.

Authors:  Anand T N Kumar; Scott B Raymond; Andrew K Dunn; Brian J Bacskai; David A Boas
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

7.  Fluorescence diffuse optical tomography for free-space and multifluorophore studies.

Authors:  Anne Koenig; Lionel Hervé; Georges Gonon; Véronique Josserand; Michel Berger; Jean-Marc Dinten; Jérome Boutet; Philippe Peltié; Jean-Luc Coll; Philippe Rizo
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

8.  Multispectral optoacoustic tomography (MSOT) scanner for whole-body small animal imaging.

Authors:  Rui Ma; Adrian Taruttis; Vasilis Ntziachristos; Daniel Razansky
Journal:  Opt Express       Date:  2009-11-23       Impact factor: 3.894

9.  A microcomputed tomography guided fluorescence tomography system for small animal molecular imaging.

Authors:  Dax Kepshire; Niculae Mincu; Michael Hutchins; Josiah Gruber; Hamid Dehghani; Justin Hypnarowski; Frederic Leblond; Mario Khayat; Brian W Pogue
Journal:  Rev Sci Instrum       Date:  2009-04       Impact factor: 1.523

10.  Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans.

Authors:  Alper Corlu; Regine Choe; Turgut Durduran; Mark A Rosen; Martin Schweiger; Simon R Arridge; Mitchell D Schnall; Arjun G Yodh
Journal:  Opt Express       Date:  2007-05-28       Impact factor: 3.894

View more
  2 in total

1.  Experimental evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Authors:  Tiffany C Kwong; Farouk Nouizi; Yuting Lin; Jaedu Cho; Yue Zhu; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Appl Opt       Date:  2017-01-20       Impact factor: 1.980

2.  A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jessica Ruiz; Jaedu Cho; Yu-Wen Chan; Kenji Ikemura; Hakan Erkol; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Phys Med Biol       Date:  2019-01-22       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.