Literature DB >> 20517387

Simultaneous fluorescence yield and lifetime tomography from time-resolved transmittances of small-animal-sized phantom.

Feng Gao1, Jiao Li, Limin Zhang, Patrick Poulet, Huijuan Zhao, Yukio Yamada.   

Abstract

There has been recently a considerable interest in simultaneously reconstructing yield and lifetime distributions of fluorescent imaging agents inside a bulky tissue, since combined monitoring of these two parameters provides a potential means of in vivo interrogating quantitative and environmental information of specific molecules, as well as accessing interactions among them. It is widely accepted that an advantageous way of accomplishing the task in the context of small-animal imaging is to use a time-domain (TD) modality. In this paper, we present a full three-dimensional, featured-data algorithm for TD diffuse fluorescence tomography, which inverts the Laplace-transformed TD coupled photon diffusion equations and employs a pair of real-domain transform-factors to effectively separate the fluorescent yield and lifetime parameters. By use of a specifically designed 16x16 channel time-correlated single photon counting system and a normalized Born formulation for the inversion, the proposed scheme in a transmission mode is experimentally validated to achieve simultaneous reconstruction of the fluorescent yield and lifetime distributions with reasonable accuracy.

Mesh:

Year:  2010        PMID: 20517387     DOI: 10.1364/AO.49.003163

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  13 in total

1.  A photo-multiplier tube-based hybrid MRI and frequency domain fluorescence tomography system for small animal imaging.

Authors:  Y Lin; M T Ghijsen; H Gao; N Liu; O Nalcioglu; G Gulsen
Journal:  Phys Med Biol       Date:  2011-07-13       Impact factor: 3.609

2.  A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jessica Ruiz; Jaedu Cho; Yu-Wen Chan; Kenji Ikemura; Hakan Erkol; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Phys Med Biol       Date:  2019-01-22       Impact factor: 3.609

3.  Shape-parameterized diffuse optical tomography holds promise for sensitivity enhancement of fluorescence molecular tomography.

Authors:  Linhui Wu; Wenbo Wan; Xin Wang; Zhongxing Zhou; Jiao Li; Limin Zhang; Huijuan Zhao; Feng Gao
Journal:  Biomed Opt Express       Date:  2014-09-16       Impact factor: 3.732

4.  Region-based diffuse optical tomography with registered atlas: in vivo acquisition of mouse optical properties.

Authors:  Wenbo Wan; Yihan Wang; Jin Qi; Lingling Liu; Wenjuan Ma; Jiao Li; Limin Zhang; Zhongxing Zhou; Huijuan Zhao; Feng Gao
Journal:  Biomed Opt Express       Date:  2016-11-14       Impact factor: 3.732

5.  Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Authors:  Yuting Lin; Farouk Nouizi; Tiffany C Kwong; Gultekin Gulsen
Journal:  Appl Opt       Date:  2015-09-01       Impact factor: 1.980

6.  Combined hemoglobin and fluorescence diffuse optical tomography for breast tumor diagnosis: a pilot study on time-domain methodology.

Authors:  Wei Zhang; Linhui Wu; Jiao Li; Xi Yi; Xin Wang; Yiming Lu; Weiting Chen; Zhongxing Zhou; Limin Zhang; Huijuan Zhao; Feng Gao
Journal:  Biomed Opt Express       Date:  2013-01-25       Impact factor: 3.732

7.  Fluorescence time-resolved imaging system embedded in an ultrasound prostate probe.

Authors:  Aurélie Laidevant; Lionel Hervé; Mathieu Debourdeau; Jérôme Boutet; Nicolas Grenier; Jean-Marc Dinten
Journal:  Biomed Opt Express       Date:  2010-12-22       Impact factor: 3.732

8.  Fluorescence lifetime optical tomography with Discontinuous Galerkin discretisation scheme.

Authors:  Vadim Y Soloviev; Cosimo D'Andrea; P Surya Mohan; Gianluca Valentini; Rinaldo Cubeddu; Simon R Arridge
Journal:  Biomed Opt Express       Date:  2010-09-20       Impact factor: 3.732

9.  Imaging workflow and calibration for CT-guided time-domain fluorescence tomography.

Authors:  Kenneth M Tichauer; Robert W Holt; Fadi El-Ghussein; Qun Zhu; Hamid Dehghani; Frederic Leblond; Brian W Pogue
Journal:  Biomed Opt Express       Date:  2011-10-05       Impact factor: 3.732

10.  Phantom and mouse experiments of time-domain fluorescence tomography using total light approach.

Authors:  Shinpei Okawa; Akira Yano; Kazuki Uchida; Yohei Mitsui; Masaki Yoshida; Masashi Takekoshi; Andhi Marjono; Feng Gao; Yoko Hoshi; Ikuhiro Kida; Kazuto Masamoto; Yukio Yamada
Journal:  Biomed Opt Express       Date:  2013-03-28       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.