Literature DB >> 28157909

Experimental evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Tiffany C Kwong, Farouk Nouizi, Yuting Lin, Jaedu Cho, Yue Zhu, Uma Sampathkumaran, Gultekin Gulsen.   

Abstract

Previously, we reported on the spatial resolution and quantitative accuracy of temperature-modulated fluorescence tomography (TM-FT) using simulation studies. TM-FT is a novel fully integrated multimodality imaging technique that combines fluorescence diffuse optical tomography (FT) with focused ultrasound. Utilizing unique thermo-reversible fluorescent nanocapsules (ThermoDots), TM-FT provides high-resolution cross-sectional fluorescence images in thick tissue (up to 6 cm). Focused ultrasound and temperature-sensitive ThermoDots are combined to provide accurate localization of these fluorescent probes and functional a priori information to constrain the conventional FT reconstruction algorithm. Our previous simulation studies evaluated the performance of TM-FT using synthetic phantoms with multiple fluorescence targets of various sizes located at different depths. In this follow-up work, we perform experimental studies to evaluate the performance of this hybrid imaging system, in particular, the effect of size, depth, and concentration of the fluorescence target. While FT alone is unable to accurately locate and resolve the fluorophore target in many cases, TM-FT is able to resolve the size and concentration of the ThermoDots within a thick turbid medium with high accuracy for all cases. The maximum error in the recovered ThermoDots concentration and target sizes with TM-FT are 12% and 25%, respectively.

Entities:  

Year:  2017        PMID: 28157909      PMCID: PMC6855591          DOI: 10.1364/AO.56.000521

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  17 in total

1.  Temperature-modulated fluorescence tomography in a turbid media.

Authors:  Yuting Lin; Linden Bolisay; Michael Ghijsen; Tiffany C Kwong; Gultekin Gulsen
Journal:  Appl Phys Lett       Date:  2012-02-15       Impact factor: 3.791

2.  Implementation of a new scanning method for high-resolution fluorescence tomography using thermo-sensitive fluorescent agents.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jaedu Cho; Yuting Lin; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Opt Lett       Date:  2015-11-01       Impact factor: 3.776

Review 3.  Fluorescence molecular imaging.

Authors:  Vasilis Ntziachristos
Journal:  Annu Rev Biomed Eng       Date:  2006       Impact factor: 9.590

4.  Comparison of imaging geometries for diffuse optical tomography of tissue.

Authors:  B Pogue; T McBride; U Osterberg; K Paulsen
Journal:  Opt Express       Date:  1999-04-12       Impact factor: 3.894

5.  Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

Authors:  Yuting Lin; Tiffany C Kwong; Linden Bolisay; Gultekin Gulsen
Journal:  J Biomed Opt       Date:  2012-05       Impact factor: 3.170

6.  High-resolution imaging in a deep turbid medium based on an ultrasound-switchable fluorescence technique.

Authors:  Baohong Yuan; Seiichi Uchiyama; Yuan Liu; Kytai T Nguyen; George Alexandrakis
Journal:  Appl Phys Lett       Date:  2012-07-17       Impact factor: 3.791

7.  Structural information within regularization matrices improves near infrared diffuse optical tomography.

Authors:  Phaneendra K Yalavarthy; Brian W Pogue; Hamid Dehghani; Colin M Carpenter; Shudong Jiang; Keith D Paulsen
Journal:  Opt Express       Date:  2007-06-25       Impact factor: 3.894

8.  Quantitative fluorescence tomography using a combined tri-modality FT/DOT/XCT system.

Authors:  Yuting Lin; William C Barber; Jan S Iwanczyk; Werner Roeck; Orhan Nalcioglu; Gultekin Gulsen
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

9.  Quantitative fluorescence tomography with functional and structural a priori information.

Authors:  Yuting Lin; Han Yan; Orhan Nalcioglu; Gultekin Gulsen
Journal:  Appl Opt       Date:  2009-03-01       Impact factor: 1.980

Review 10.  Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications.

Authors:  Frederic Leblond; Scott C Davis; Pablo A Valdés; Brian W Pogue
Journal:  J Photochem Photobiol B       Date:  2009-11-26       Impact factor: 6.252

View more
  3 in total

1.  A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jessica Ruiz; Jaedu Cho; Yu-Wen Chan; Kenji Ikemura; Hakan Erkol; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Phys Med Biol       Date:  2019-01-22       Impact factor: 3.609

2.  Feasibility study of high spatial resolution multimodality fluorescence tomography in ex vivo biological tissue.

Authors:  Tiffany C Kwong; Farouk Nouizi; Jaedu Cho; Yuting Lin; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Appl Opt       Date:  2017-10-01       Impact factor: 1.980

3.  Improving sensitivity and imaging depth of ultrasound-switchable fluorescence via an EMCCD-gain-controlled system and a liposome-based contrast agent.

Authors:  Tingfeng Yao; Yang Liu; Liqin Ren; Baohong Yuan
Journal:  Quant Imaging Med Surg       Date:  2021-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.