Literature DB >> 26359871

Impact of radiation dose and iterative reconstruction on pulmonary nodule measurements at chest CT: a phantom study.

Hyungjin Kim1, Chang Min Park, Hee Dong Chae, Sang Min Lee, Jin Mo Goo.   

Abstract

PURPOSE: We aimed to identify the impact of radiation dose and iterative reconstruction (IR) on measurement of pulmonary nodules by chest computed tomography (CT).
METHODS: CT scans were performed on a chest phantom containing various nodules (diameters of 3, 5, 8, 10, and 12 mm; +100, -630 and -800 HU for each diameter) at 80, 100, 120 kVp and 10, 20, 50, 100 mAs (a total of 12 radiation dose settings). Each CT was reconstructed using filtered back projection, iDose4, and iterative model reconstruction (IMR). Thereafter, two radiologists measured the diameter and attenuation of the nodules. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. Influence of radiation dose and reconstruction algorithm on measurement error and objective image quality metrics was analyzed using generalized estimating equations.
RESULTS: The 80 kVp, 10 mAs CT scan was not feasible for the measurement of 3 mm sized simulated ground-glass nodule (GGN); otherwise, diameter measurement error was not significantly influenced by radiation dose (P > 0.05). IR did not have a significant impact on diameter measurement error for simulated solid nodules (P > 0.05). However, for simulated GGNs, IMR was associated with significantly decreased relative diameter measurement error (P < 0.001). Attenuation measurement error was not significantly influenced by either radiation dose or reconstruction algorithm (P > 0.05). Objective image quality was significantly better with IMR (P < 0.05).
CONCLUSION: Nodule measurements were not affected by radiation dose except for 3 mm simulated GGN on 80 kVp, 10 mAs dose setting. However, for GGNs, IMR may help reduce diameter measurement error while improving image quality.

Mesh:

Year:  2015        PMID: 26359871      PMCID: PMC4622392          DOI: 10.5152/dir.2015.14541

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  22 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society.

Authors:  Heber MacMahon; John H M Austin; Gordon Gamsu; Christian J Herold; James R Jett; David P Naidich; Edward F Patz; Stephen J Swensen
Journal:  Radiology       Date:  2005-11       Impact factor: 11.105

Review 3.  Radiation dose reduction in chest CT: a review.

Authors:  Takeshi Kubo; Pei-Jan Paul Lin; Wolfram Stiller; Masaya Takahashi; Hans-Ulrich Kauczor; Yoshiharu Ohno; Hiroto Hatabu
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

4.  Linear and volume measurements of pulmonary nodules at different CT dose levels - intrascan and interscan analysis.

Authors:  P A Hein; V C Romano; P Rogalla; C Klessen; A Lembcke; V Dicken; L Bornemann; H-C Bauknecht
Journal:  Rofo       Date:  2008-12-11

5.  Variability of lung tumor measurements on repeat computed tomography scans taken within 15 minutes.

Authors:  Geoffrey R Oxnard; Binsheng Zhao; Camelia S Sima; Michelle S Ginsberg; Leonard P James; Robert A Lefkowitz; Pingzhen Guo; Mark G Kris; Lawrence H Schwartz; Gregory J Riely
Journal:  J Clin Oncol       Date:  2011-07-05       Impact factor: 44.544

6.  Systematic error in lung nodule volumetry: effect of iterative reconstruction versus filtered back projection at different CT parameters.

Authors:  Martin J Willemink; Tim Leiner; Ricardo P J Budde; Freek P L de Kort; Rozemarijn Vliegenthart; Peter M A van Ooijen; Matthijs Oudkerk; Pim A de Jong
Journal:  AJR Am J Roentgenol       Date:  2012-12       Impact factor: 3.959

7.  A concordance correlation coefficient to evaluate reproducibility.

Authors:  L I Lin
Journal:  Biometrics       Date:  1989-03       Impact factor: 2.571

8.  Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography.

Authors:  Yoshinori Funama; Katsuyuki Taguchi; Daisuke Utsunomiya; Seitaro Oda; Yumi Yanaga; Yasuyuki Yamashita; Kazuo Awai
Journal:  J Comput Assist Tomogr       Date:  2011 Jul-Aug       Impact factor: 1.826

9.  Reduced lung-cancer mortality with low-dose computed tomographic screening.

Authors:  Denise R Aberle; Amanda M Adams; Christine D Berg; William C Black; Jonathan D Clapp; Richard M Fagerstrom; Ilana F Gareen; Constantine Gatsonis; Pamela M Marcus; JoRean D Sicks
Journal:  N Engl J Med       Date:  2011-06-29       Impact factor: 91.245

10.  Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

Authors:  Paul D Deak; Yulia Smal; Willi A Kalender
Journal:  Radiology       Date:  2010-10       Impact factor: 11.105

View more
  8 in total

1.  Effect of iterative reconstruction techniques on image quality in low radiation dose chest CT: a phantom study.

Authors:  Yan Xu; Ting-Ting Zhang; Zhi-Hai Hu; Juan Li; Hong-Jun Hou; Zu-Shan Xu; Wen He
Journal:  Diagn Interv Radiol       Date:  2019-11       Impact factor: 2.630

2.  Improved repeatability of subsolid nodule measurement in low-dose lung screening with monoenergetic images: a phantom study.

Authors:  Jihang Kim; Kyung Hee Lee; Junghoon Kim; Yoon Joo Shin; Kyung Won Lee
Journal:  Quant Imaging Med Surg       Date:  2019-02

3.  Quantitative assessment of nonsolid pulmonary nodule volume with computed tomography in a phantom study.

Authors:  Marios A Gavrielides; Benjamin P Berman; Mark Supanich; Kurt Schultz; Qin Li; Nicholas Petrick; Rongping Zeng; Jenifer Siegelman
Journal:  Quant Imaging Med Surg       Date:  2017-12

4.  Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT.

Authors:  Ki Baek Lee; Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

5.  Accuracy of Model-Based Iterative Reconstruction for CT Volumetry of Part-Solid Nodules and Solid Nodules in Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction at Various Dose Settings: An Anthropomorphic Chest Phantom Study.

Authors:  Seung Kwan Kim; Cherry Kim; Ki Yeol Lee; Jaehyung Cha; Hyun Ju Lim; Eun Young Kang; Yu Whan Oh
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

6.  Evaluate the performance of four artificial intelligence-aided diagnostic systems in identifying and measuring four types of pulmonary nodules.

Authors:  Ming-Yue Wu; Yong Li; Bin-Jie Fu; Guo-Shu Wang; Zhi-Gang Chu; Dan Deng
Journal:  J Appl Clin Med Phys       Date:  2020-12-24       Impact factor: 2.102

7.  Diameter of the Solid Component in Subsolid Nodules on Low-Dose Unenhanced Chest Computed Tomography: Measurement Accuracy for the Prediction of Invasive Component in Lung Adenocarcinoma.

Authors:  Hyungwoo Ahn; Kyung Hee Lee; Jihang Kim; Jeongjae Kim; Junghoon Kim; Kyung Won Lee
Journal:  Korean J Radiol       Date:  2018-04-06       Impact factor: 3.500

8.  Nodule Classification on Low-Dose Unenhanced CT and Standard-Dose Enhanced CT: Inter-Protocol Agreement and Analysis of Interchangeability.

Authors:  Kyung Hee Lee; Kyung Won Lee; Ji Hoon Park; Kyunghwa Han; Jihang Kim; Sang Min Lee; Chang Min Park
Journal:  Korean J Radiol       Date:  2018-04-06       Impact factor: 3.500

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.