Literature DB >> 19085687

Linear and volume measurements of pulmonary nodules at different CT dose levels - intrascan and interscan analysis.

P A Hein1, V C Romano, P Rogalla, C Klessen, A Lembcke, V Dicken, L Bornemann, H-C Bauknecht.   

Abstract

PURPOSE: To compare the interobserver variability of the unidimensional diameter and volume measurements of pulmonary nodules in an intrascan and interscan analysis using semi-automated segmentation software on ultra-low-dose computed tomography (ULD-CT) and standard dose CT (SD-CT) data.
MATERIALS AND METHODS: In 33 patients with pulmonary nodules, two chest multi-slice CT (MSCT) datasets (1 mm slice thickness; 20 % reconstruction overlap) had been consecutively acquired with an ultra-low dose (120 kV, 5 mAs) and standard dose technique (120 kV, 75 mAs). MSCT data was retrospectively analyzed using the segmentation software OncoTREAT (MeVis, Bremen, Germany, version 1.3). The volume of 229 solid pulmonary nodules included in the analysis as well as the largest diameter according to RECIST (Response Evaluation Criteria for Solid Tumors) were measured by two radiologists. Interobserver variability was calculated and SD-CT and ULD-CT data compared in an intrascan and interscan analysis.
RESULTS: The median nodule diameter (n = 229 nodules) was registered with 8.2 mm (range: 2.8 to 43.6 mm, mean: 10.8 mm). The nodule volume ranged between 0.01 and 49.1 ml (median 0.1 ml, mean 1.5 ml). With respect to interobserver variability, the intrascan analysis did not reveal statistically significant differences (p > 0.05) between ULD-CT and SD-CT with broader limits of agreement for relative differences of RECIST measurements (-31.0 % + 27.0 % mean -2.0 % for SD-CT; -27.0 % + 38.6 %, mean 5.8 % for ULD-CT) than for volume measurements (-9.4 %, 8.0 %, mean 0.7 % for SD-CT; -13 %, 13 %, mean 0.0 % for ULD-CT). The interscan analysis showed broadened 95 % confidence intervals for volume measurements (-26.5 % 29.1 % mean 1.3 %, and -25.2 %, 29.6 %, mean 2.2 %) but yielded comparable limits of agreement for RECIST measurements.
CONCLUSION: The variability of nodule volumetry assessed by semi-automated segmentation software as well as nodule size determination by RECIST appears to be independent of the acquisition dose in the CT source dataset. This is particularly important regarding size determination of pulmonary nodules in screening trials using low-dose CT data for follow-up imaging.

Entities:  

Mesh:

Year:  2008        PMID: 19085687     DOI: 10.1055/s-2008-1027874

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  10 in total

1.  Semi-automated volumetric analysis of lymph node metastases during follow-up--initial results.

Authors:  Michael Fabel; H Bolte; H von Tengg-Kobligk; L Bornemann; V Dicken; S Delorme; H-U Kauczor; M Heller; J Biederer
Journal:  Eur Radiol       Date:  2010-10-17       Impact factor: 5.315

2.  Impact of radiation dose and iterative reconstruction on pulmonary nodule measurements at chest CT: a phantom study.

Authors:  Hyungjin Kim; Chang Min Park; Hee Dong Chae; Sang Min Lee; Jin Mo Goo
Journal:  Diagn Interv Radiol       Date:  2015 Nov-Dec       Impact factor: 2.630

3.  Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study.

Authors:  X Xie; M J Willemink; Y Zhao; P A de Jong; P M A van Ooijen; M Oudkerk; M J W Greuter; R Vliegenthart
Journal:  Br J Radiol       Date:  2013-07-24       Impact factor: 3.039

4.  Accuracy of two deep learning-based reconstruction methods compared with an adaptive statistical iterative reconstruction method for solid and ground-glass nodule volumetry on low-dose and ultra-low-dose chest computed tomography: A phantom study.

Authors:  Cherry Kim; Thomas Kwack; Wooil Kim; Jaehyung Cha; Zepa Yang; Hwan Seok Yong
Journal:  PLoS One       Date:  2022-06-23       Impact factor: 3.752

Review 5.  Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology.

Authors:  Douglas E Wood; Ella A Kazerooni; Scott L Baum; George A Eapen; David S Ettinger; Lifang Hou; David M Jackman; Donald Klippenstein; Rohit Kumar; Rudy P Lackner; Lorriana E Leard; Inga T Lennes; Ann N C Leung; Samir S Makani; Pierre P Massion; Peter Mazzone; Robert E Merritt; Bryan F Meyers; David E Midthun; Sudhakar Pipavath; Christie Pratt; Chakravarthy Reddy; Mary E Reid; Arnold J Rotter; Peter B Sachs; Matthew B Schabath; Mark L Schiebler; Betty C Tong; William D Travis; Benjamin Wei; Stephen C Yang; Kristina M Gregory; Miranda Hughes
Journal:  J Natl Compr Canc Netw       Date:  2018-04       Impact factor: 11.908

6.  Diagnostic study on clinical feasibility of an AI-based diagnostic system as a second reader on mobile CT images: a preliminary result.

Authors:  Kaiyue Diao; Yuntian Chen; Ying Liu; Bo-Jiang Chen; Wan-Jiang Li; Lin Zhang; Ya-Li Qu; Tong Zhang; Yun Zhang; Min Wu; Kang Li; Bin Song
Journal:  Ann Transl Med       Date:  2022-06

7.  The effects of computed tomography with iterative reconstruction on solid pulmonary nodule volume quantification.

Authors:  Martin J Willemink; Jaap Borstlap; Richard A P Takx; Arnold M R Schilham; Tim Leiner; Ricardo P J Budde; Pim A de Jong
Journal:  PLoS One       Date:  2013-02-27       Impact factor: 3.240

8.  Changes of lung tumour volume on CT - prediction of the reliability of assessments.

Authors:  Hubert Beaumont; Simon Souchet; Jean Marc Labatte; Antoine Iannessi; Anthony William Tolcher
Journal:  Cancer Imaging       Date:  2015-10-31       Impact factor: 3.909

9.  Diameter of the Solid Component in Subsolid Nodules on Low-Dose Unenhanced Chest Computed Tomography: Measurement Accuracy for the Prediction of Invasive Component in Lung Adenocarcinoma.

Authors:  Hyungwoo Ahn; Kyung Hee Lee; Jihang Kim; Jeongjae Kim; Junghoon Kim; Kyung Won Lee
Journal:  Korean J Radiol       Date:  2018-04-06       Impact factor: 3.500

10.  Application of artificial intelligence in the diagnosis of multiple primary lung cancer.

Authors:  Xin Li; Bin Hu; Hui Li; Bin You
Journal:  Thorac Cancer       Date:  2019-09-17       Impact factor: 3.500

  10 in total